The paper describes a new system, the Roof Radiation Trap, which utilizes solar energy for heating of buildings in winter and nocturnal radiation for cooling in summer. The radiation trap consists of fixed insulating layer separated from the flat roof and glazing, protected by hinged insulating panel, in the southern gap between the roof and the fixed insulation. This fixed insulating layer is covered by corrugated metal sheets, painted white, which serve as nocturnal radiators in summer.The radiation trap is integrated with the building, thermally as well as architecturally. In winter the sun energy penetrates through the glazing and is absorbed directly in the roof, which serves as a combined collector, storage for one night and heat distribution system.The hot air in the space between the flat roof and the fixed insulation is blown into a thermal storage of gravel, under the floor or inside the building. The stored heat is “recovered” by forced convection during cloudy days.In summer the penetration of solar radiation during daytime is prevented by the hinged insulating panel. At night the painted external metal layer is cooled by outgoing radiation and the air under the corrugations is blown into the space of the radiation trap and cools the roof, which, in turn, serves as a heat sink during the next day. Nocturnal evaporative cooling can supplement the radiant cooling. 相似文献
Russian Electrical Engineering - In this paper, we ground a method for calculating switching overvoltages including the discharge of lightning currents into the contact network and into a... 相似文献
Russian Electrical Engineering - The cells of homogeneous digital structures designed for multioperation process diagnostics are considered in the form of graphic models. Digital circuits and... 相似文献
Despite significant on-going investment, water companies continue to receive an unacceptable number of discolouration related customer contacts. In this paper, data from intensive distribution system turbidity monitoring and cluster analysis of discolouration customer contacts indicate that a significant proportion of these contacts are due to material mobilising from the trunk main system, and operational flow increases are shown to have a higher discolouration risk than burst incidents. A trunk main discolouration incident highlighting this risk is discussed, demonstrating the need for pro-active trunk main risk assessments. To identify the source of the material event flow rates were modelled using the PODDS (prediction of discolouration in distribution systems) discolouration model. Best practice pro-active management is demonstrated in a case study where the PODDS model is used to implement managed incremental flow changes on a main with known discolouration risk with no discolouration impact to customers and significant cost savings. 相似文献
This article presents the results of experimental studies on a coal mine. According to the results, the current of single phase-to-earth fault in the network under 1000 V has a value less than the current of the residual current device set point. This article presents a method aimed to improving the efficiency of the residual current device used on excavators and drill-rings at mining enterprises. Indeed, the method developed to improve the efficiency of residual current devices under 1000 V is based on setting up a direct current into three-phase mains with a fixed set-point of protection against any phase-to-ground insulation damage, where electric equipment is switched off due to increases of capacitance between a conductor and earth when live-line bare-hand touching of electric equipment occurs. 相似文献
A model of a continuum with a structure described by infinite order equations of motion is proposed. In case that a wave is very long as compared with the size of the structure, equations are reduced to the fourth-order equations. A closed equation of motion, including nonlinear, dispersed and wave members, is derived. It is shown that solutions in the form of soliton waves exist only in media where wave velocity grows with pressure. In the media, where soliton waves do not exist, quasi-stationary solutions with multiple frequencies prevail. It is found that the nonlinear effect of multiple frequencies is unexpectedly high even for small deformation as dispersion violently intensifies nonlinear events. Moreover, in the domain of small deformation, there exist solutions for longitudinal and transversal waves with the same length and different frequencies. The solutions for the same length waves with different frequencies most often occur in seismology and seismic explorations. 相似文献
Metallurgical and Materials Transactions A - Equal channel angular extrusion (ECAE) of 49Fe-49Co-2V, also known as Hiperco® 50A or Permendur-2V, greatly improves the strength and ductility of... 相似文献
The present investigations focused on the thermal oxidation of two variants of MAR-M246 alloy having the same contents of Ta and Nb in at. pct, considering the effects of total replacement of Ta by Nb. The alloys were produced by investment casting using high purity elements in induction furnace under vacuum atmosphere. The alloys were oxidized pseudo-isothermally at 800 °C, 900 °C and 1000 °C up to 1000 hours under lab air. Protective oxidation products growing on the surface of the oxidized samples were mainly Al2O3, Cr2O3. Other less protective oxide such as spinels (NiCr2O4 and CoCr2O4) and TiO2 were also detected as oxidation products. The conventional alloy exhibited slight internal oxidation at 800 °C and an enhanced resistance at 900 °C and 1000 °C. The Nb-modified alloy presented an exacerbated internal oxidation and nitridation at 900 °C and 1000 °C and an enhanced resistance at 800 °C. At 1000 °C, Nb-modified alloy was particularly affected by excessive spalling as the main damage mechanisms. From a kinetic point of view, both alloys exhibit the same behavior at 800 °C and 900 °C, with kp values typical of alumina forming alloys (2 × 10−14 to 3.6 × 10−13 g2 cm−4 s−1). However, Ta modified alloys exhibited superior oxidation resistance at 1000 °C when compared to the Nb modified alloy due to better adherence of the protective oxide scale.
Metallurgist - The article presents the results of plastometric studies on hot deformation and studies on the hardening curves in cold deformation of EP450-Sh (12H12M1BFR-Sh) and EP823-Sh... 相似文献