The diffusion coefficient at zero penetrant concentration D0 of dichloromethane, chloroform, carbon tetrachloride, cyclohexane, benzene, o-xylene, m-xylene, and p-xylene, and n-hexane in LDPE were measured at 25°C, using the desorption method. The D0 values obtained in this way are correlated with the size, shape, and chemical nature of the penetrant molecules. The temperature dependence of the diffusion coefficients of toluene and n-hexane in LDPE are also reported in the limited temperature range of 25–45°C. It indicates that, in spite of a size larger than that of toluene, n-hexane has a lower activation energy of diffusion. 相似文献
The corrosion of a number of experimental ternary Ni-15 wt. % Cr-0.5wt. %X alloys (where X= Y, La, Ce, Sm, Th, U, Zr, or V) has been assessed in pure oxygen at 900° C for periods of exposure up to 450 hr, and compared with the behavior of an Ni-15% Cr control alloy. It has been established that while all of the alloys oxidize in accordance with a protective, approximately parabolic regime, considerable differences in oxidation rates are exhibited. In particular, additions of La, Ce, and Th bring about progressively enhanced rates of oxidation relative to the binary alloy, whereas Y, Sm, V, U, and Zr effect increasingly reduced rates of oxidation in the order given. The rate constant for the Th-bearing alloy is about two orders of magnitude larger than that for the alloy containing Zr. Such differences in behavior seem to be associated with subtle variations in the morphology/composition of the corrosion products from alloy to alloy. The observations are considered in the light of earlier published literature concerning the effects of rare-earth and other reactive elements on the oxidation behavior of Ni/Cr alloys.This work has been carried out with the support of Procurement Executive, Ministry of Defence. 相似文献
Research on better methods to digitally represent microscopic specimens has increased over recent decades. Opaque specimens, such as microfossils and metallurgic specimens, are often viewed using reflected light microscopy. Existing 3D surface estimation techniques for reflected light microscopy do not model reflectance, restricting the representation to only one illumination condition and making them an imperfect recreation of the experience of using an actual microscope. This paper introduces a virtual reflected-light microscopy (VRLM) system that estimates both shape and reflectance from a set of specimen images. When coupled with anaglyph creation, the system can depict both depth information and illumination cues under any desired lighting configuration. Digital representations are compact and easily viewed in an online setting. A prototype used to construct VRLM representations is comprised only of a microscope, a digital camera, a motorized stage and software. Such a system automatically acquires VRLM representations of large batches of specimens. VRLM representations are then disseminated in an interactive online environment, which allows users to change the virtual light source direction and type. Experiments demonstrate high quality VRLM representations of 500 microfossils. 相似文献
Microsystem Technologies - The dynamic performance of a micro-resonator depends on its energy loss mechanism which is quantified by Q-factor (Quality factor). This paper presents numerical... 相似文献
Blood oxygenation can be measured using magnetic resonance using the paramagnetic effect of deoxy-haemoglobin, which decreases the \(\textit{T}_{2}\) relaxation time of blood. This \(\textit{T}_{2}\) contrast has been well characterised at the \(\textit{B}_{{0}}\) fields used in MRI (1.5 T and above). However, few studies have characterised this effect at lower magnetic fields. Here, the feasibility of blood oximetry at low field based on \(\textit{T}_{2}\) changes that are within a physiological relevant range is explored. This study could be used for specifying requirements for construction of a monitoring device based on low field permanent magnet systems.
Methods
A continuous flow circuit was used to control parameters such as oxygen saturation and temperature in a sample of blood. It flowed through a variable field magnet, where CPMG experiments were performed to measure its \(\textit{T}_{2}\). In addition, the oxygen saturation was monitored by an optical sensor for comparison with the \(\textit{T}_{2}\) changes.
Results
These results show that at low \(\textit{B}_{{0}}\) fields, the change in blood \(\textit{T}_{2}\) due to oxygenation is small, but still detectable. The data measured at low fields are also in agreement with theoretical models for the oxy-deoxy \(\textit{T}_{2}\) effect.
Conclusion
\(\textit{T}_{2}\) changes in blood due to oxygenation were observed at fields as low as 0.1 T. These results suggest that low field NMR relaxometry devices around 0.3 T could be designed to detect changes in blood oxygenation.
The classic hypoglossal transfer to the facial nerve is invariably followed by complications caused by tongue atrophy. In 1984, Terzis introduced the "baby-sitter" procedure which involved a formal cross-facial procedure, in addition to partial neurectomy of the hypoglossal nerve, and an end-to-side coaptation with the ipsilateral facial nerve. This reported study provides, for the first time, quantification of the number of hypoglossal motor fibers needed to successfully restore eye sphincter function, using an end-to-side coaptation with preservation of the tongue. Thirty adult Sprague-Dawley rats were divided into six groups: control, denervated, perineurial window, 20 percent partial neurectomy (PN), 40 percent PN, and 80 percent PN. The procedure involves interposing a nerve graft (saphenous) between the partially severed XII nerve and the upper zygomatic branch of the facial nerve. Evaluation of the behavioral data (blink reflex) revealed good-to-superb return of the blinking mechanism in the 40 percent group, without significant tongue atrophy. Electrophysiologic data in the 40 percent neurectomy group demonstrated superiority to the other groups. Quantitative axonal morphometry of the coaptation sites and graft, as well as motor end-plates of the orbicularis oculi muscle and tongue showed the 40 percent partial neurectomy group to be the optimal group. 相似文献
BACKGROUND/PURPOSE: Fetuses with congenital diaphragmatic hernia (CDH) who have a "poor prognosis" with postnatal treatment now can be identified on the basis of liver herniation, early diagnosis (before 25 weeks' gestation) and a low lung-to-head ratio (LHR). Because complete in utero repair proved unsuccessful for this group, the strategy of temporary tracheal occlusion was developed to gradually enlarge the hypoplastic fetal lung. The purpose of this study is to compare the outcome of patients in the poor-prognosis group treated by one of three methods: (1) standard postnatal care, (2) fetal tracheal occlusion via open hysterotomy, and (3) the recently developed video-fetoscopic (Fetendo) technique of tracheal occlusion without hysterotomy. METHODS: In the past 3 years, 34 of 86 fetuses with an isolated left CDH met criteria for the poor-prognosis group. Thirteen families chose postnatal treatment at an extracorporeal membrane oxygenation (ECMO) center, 13 underwent open fetal tracheal occlusion, and eight underwent fetoscopic tracheal occlusion. RESULTS: The survival rate was 38% in the group treated by standard postnatal therapy, 15% in the open tracheal occlusion group, and 75% in the Fetendo group. There were less postoperative pulmonary complications noted in mothers who underwent the Fetendo procedure versus the open tracheal occlusion. All but one Fetendo clip patient had a striking physiological response demonstrated by sonographic enlargement of the small left lung that was documented postnatally by plain radiographs and its subjective appearance during repair of the CDH. In contrast, only 5 of the 13 open tracheal occlusion patients demonstrated lung growth. CONCLUSION: Fetuses with a left CDH who have liver herniation and a low LHR are at high risk of neonatal demise and appear to benefit from temporary tracheal occlusion when performed fetoscopically, but not when performed by open fetal surgery. 相似文献
This paper presents research into the application of the fuzzy ARTMAP neural network model to the diagnosis of cancer from fine-needle aspirates of the breast. Trained fuzzy ARTMAP networks are differently pruned so as to maximise accuracy, sensitivity and specificity. The differently pruned networks are then employed in a cascade of networks intended to separate cases into certain and suspicious classes. This mimics the predictive behaviour of a human pathologist. The fuzzy ARTMAP model also provides symbolic rule extraction facilities and the validity of the derived rules for this domain is discussed. Additionally, results are provided showing the effects upon network performance of different input features and different observers. The implications of the findings are discussed. 相似文献
Methods to fabricate planar capillary electrophoresis devices integrated with a postcolumn reactor in fused silica (quartz) and Pyrex glass are presented. Quartz is etched at ~1 μm/min with a 2.1:1 width-to-depth ratio using a Cr/Au/Cr metal mask and concentrated HF/HNO(3). On-chip postcolumn reaction of o-phthaldialdehyde (OPA) and amino acids gave theoretical plate numbers up to 83?000 and ~90 ms peak widths, corresponding to 14 plates/V and a 0.5 μm theoretical plate height. The reactor geometry caused only a 10% degradation in efficiency. 相似文献