The purpose of this paper is to present a formulation of a curved thin-walled box beam finite element having a variable cross-section with at least one vertical axis of symmetry.
To allow for the effects of warping and distortion, three degrees of freedom have been included in the formulation. These degrees of freedom have been designated as the rate of change of twisting angle, the distortional angle of the cross-section, and the rate of change of distortional angle. The effect of shear lag has also been included.
The element may be used for the elastic analysis of a variety of thin-walled structures and in particular for the preliminary analysis of box bridge decks where a three-dimensional analysis may be unnecessary. The accuracy of the element has been demonstrated by comparison of the results obtained with known results from other methods for some examples. 相似文献
The destruction of the carcinogen benzo[a]pyrene (BaP) by light is well known; laboratory workers are routinely advised to cover fluorescent lamps with yellow filters while treating samples containing BaP. However until recently the mechanism of oxidation by sunlight and ozone had not been studied in detail. Concentrations of benzo[a]pyrene in urban air are in the range of 5–10 μg/1000 m3. Oxidant concentrations (predominantly in the form of ozone) are reported to be in the range of 0.01 ppm (22 μg per m3). Thus a sampling system with a filter paper would filter about 22,000 μg of ozone passing through and collect about 5 μg of BaP for analysis. The effect of interactions of such large ozone concentrations with BaP deposited on the filter paper is reported; data for the oxidation rates for benzo[a]pyrene coated on quartz surface and exposed to ozone or sunlight are presented. The oxidation products were analysed by thin-layer chromatography and highpressure liquid chromatography. From about eight products detected in these experiments, three have been identified as quinones based on UV-absorption spectrometry and mass spectrometry. Oxidation rates as high as 100% per hour of exposure are observed when less than 0.1 μg of BaP is coated inside the quartz tubes and exposed to ozone or sunlight. Oxidation rates for benzo[a]pyrene (using tritiated BaP) were determined for two types of experimental conditions. In the first set, tritiated BaP was spotted onto a glass fibre paper and sampling continued for 24 h; the loss of BaP was found to be 88%. In the second set tritiated BaP was spotted at intervals of one hour, for eight hours, while sampling is being carried out and the loss of BaP during the period was estimated to be 50%. 相似文献
In the air conditioning (AC) industry chilled water storage (CWS) systems are one form of cool thermal storage technology that can be used to time shift the electrical load of the system from the peak day periods to off peak night time periods. In this paper the data for the actual exported and generated electrical energy obtained for the power stations in Kuwait has been used to estimate the electrical energy consumption and the peak electrical load of AC systems. Since the chiller in an air cooled AC system represent more than 75% of the total electrical power consumed by an AC system during the peak demand period, the impact of using CWS systems with alternative operating strategies including partial (load levelling), partial (demand limiting) and full load has been investigated. In our conclusions we estimate that approximately 45% of the total annual exported electrical energy is consumed solely by AC systems as a result of the very high ambient temperatures occurring between March and October. Furthermore, it is estimated AC systems represent about 62% of the peak electrical load. The results demonstrate that CWS can reduce the peak electrical load of a chiller in an air cooled AC system by up to 100% and reduce the nominal chiller size by up to 33% depending upon the operating strategy adopted. This is achieved with only a 4% increase in power consumption of the chiller for all CWS strategies except for full storage where the energy consumption actually decreases by approximately 4%. 相似文献
Heavy metal concentrations have been determined in maternal and cord blood samples collected from mothers in the age group 20-25 years with full-term neonates (37-40 weeks). The concentrations of Pb, Cd, Cu and Zn were found to be low in cord blood as compared to mother's blood and the ratio between cord blood and maternal blood for the respective elements was found to be approximately 0.80, 0.86, 0.47 and 0.40. On the other hand, the concentrations of Fe and Mg in the mother's blood were found to be lower than those in the cord blood. Prenatal exposure to lead in Mumbai, though low (5.1 microg/dl), is approximately 2-3 times higher than that observed in Canada or Italy. A strong correlation (r = 0.79) between the maternal and cord blood lead levels has been observed during the present study. 相似文献
GaN-based ultraviolet-C (UV-C) light emitting diodes (LEDs) are of great interest for water disinfection. They offer significant advantages compared to conventional mercury lamps due to their compact form factor, low power requirements, high efficiency, non-toxicity, and overall robustness. However, despite the significant progress in the performance of semiconductor based UV LEDs that has been achieved in recent years, these devices still suffer from low emission power and relatively short lifetimes. Even the best UV LEDs exhibit external quantum efficiencies of only 1-2%.The objective of this study was to investigate the suitability of GaN-based UV LEDs for water disinfection. The investigation included the evaluation of the performance characteristics of UV LEDs at different operating conditions as well as the design of a UV LED module in view of the requirements for water treatment applications. Bioanalytical testing was conducted using Bacillus subtilis spores as test organism and UV LED modules with emission wavelengths of 269 nm and 282 nm.The results demonstrate the functionality of the developed UV LED disinfection modules. GaN-based UV LEDs effectively inactivated B. subtilis spores during static and flow-through tests applying varying water qualities. The 269 nm LEDs reached a higher level of inactivation than the 282 nm LEDs for the same applied fluence. The lower inactivation achieved by the 282 nm LEDs was compensated by their higher photon flux. First flow-through tests indicate a linear correlation between inactivation and fluence, demonstrating a well designed flow-through reactor. With improved light output and reduced costs, GaN-based UV LEDs can provide a promising alternative for decentralised and mobile water disinfection systems. 相似文献
Laboratory specimens with a smooth boundary (no notch) were fabricated from four different rock types (grain sizes from 0.1–10 mm) and were tested in three-point bending. The locations of acoustic emission that occurred around peak load were used to characterize the dimensions of the region of localized microcracking, the so-called intrinsic process zone. The size of this zone was found to vary significantly between the rock types, but was not found to vary significantly for different size beams of the same material. An approximately linear relation was found between the width of the intrinsic process zone and the logarithm of the grain size. An explanation of size effect evolves naturally by considering the intrinsic process zone as a material characteristic. Two different models were used to analyze stress at failure. The first treated the intrinsic process zone as a mathematical crack, an infinite stress raiser, from which a KIC value was calculated. The second model assumed the intrinsic process zone was a cohesive notch, a finite stress raiser, from which the theoretical tensile strength was defined. The second method seemed somewhat better at predicting size effect on nominal peak stress. 相似文献
Concentrations of trace elements in human tissues characteristically vary widely, and the distributions of most concentrations are skewed to the right. Examination of some of the factors which contribute to the marked variability and skewness of the concentrations revealed that: (1) distributions of concentrations are satisfactorily normal (Gaussian) after logarithmic transformation, (2) ash weight is the best frame of reference in which to report results, (3) the distributions of metal concentrations are not further normalized by adjustments which assume that tissue lipid or collagen contains a fixed fraction of the metal found in the parenchyma, and (4) the choice of sample site within the liver is of minimal significance. 相似文献
Recent changes in the construction of building floors have included the use of light material composite systems and long span floor systems. Although these changes have many advantages, such floor systems can suffer from excessive vibration due to human activities. This problem is exacerbated in office buildings due to the reduction in inherent damping associated with modern fit outs. Excessive floor vibrations are often realised after the completion of construction or following structural modifications and normally arise due to inadequate knowledge of the damping values in the design process. Thus rectification measures are normally required to reduce floor accelerations. This paper proposes a new innovative passive viscoelastic damper to reduce floor vibrations. This damper can be easily tuned to the fundamental frequency of the floor and can be designed to achieve various damping values. The paper discusses the analytical development of the damper with experimental results presented on a prototype to demonstrate its effectiveness. 相似文献