The TELEMAC project brings new methodologies from the Information and Science Technologies field to the world of water treatment. TELEMAC offers an advanced remote management system which adapts to most of the anaerobic wastewater treatment plants that do not benefit from a local expert in wastewater treatment. The TELEMAC system takes advantage of new sensors to better monitor the process dynamics and to run automatic controllers that stabilise the treatment plant, meet the depollution requirements and provide a biogas quality suitable for cogeneration. If the automatic system detects a failure which cannot be solved automatically or locally by a technician, then an expert from the TELEMAC Control Centre is contacted via the internet and manages the problem. 相似文献
The increasing complecity of many expert system application areas calls for the integration of the knowledge of multiple experts. The use of multiple experts introduces some interesting new problems during the process of knowledge acquisition. The problems are further complicated when the experts are geographically dispersed or unavailable for face-to-face interactions.
This article discusses the motivations for acquiring the knowledge of multiple experts, the problems related to knowledge acquisition, new issues that arise whens multiple experts interact, solutions that can be brought to bear in building multiple expert systems (particularly when experts are geographically dispersed), and new tools for knowledge engineers to use when dealing with multiple experts. 相似文献
Corrosion behaviour of aluminium-lithium alloys The AlLiMgCu alloy 8090 was studied in its texturated fine grained version “A” and in its recrystallized coarse grain structured version “C” in different artificially aged conditions in reference to several other AlLi alloys, each in its heat treatment condition of practical interest, and to the convetional alloy 2024 T3. The subject of research was the general corrosion behaviour of semifinished AlLi products, particularly sheet material, under alternate and permanent immersion conditions in neutral 3.5% sodium chloride solution; the stress corrosion behaviour was studied under constant load in the long transverse direction according to ASTM G44 and G49. The underaged conditions, which are the relevant conditions for technical application of the 8090 “A” and “C” sheets, showed an approximately equivalent or even better corrosion behaviour in comparison to the lithium-free alloy 2024 T3 in the corrosion tests with unloaded specimens. The threshold above which the AlLi alloy 8090 in some heat treatment conditions is attacked by stress corrosion cracking within the 30 days lasting constant load test depends on alloy composition, testing direction, grain size, stretch-forming, artificial ageing condition, surface pretreatment and the specimens' dimensions. 相似文献
The effect of ion exchange conditions, such as Si/Al ratio, precursor copper salt, pH and concentration of the solution, on the catalytic activity in SCR of NO by propane and on the electronic state of copper ions in Cu-ZSM-5 has been studied. The NO conversion in NO SCR by C3H8 has been found to reach a maximum value at Cu/Al ratio about 0.37–0.4 and remain constant at higher Cu/Al.
ESR and UV–vis DR spectroscopy have been used to elucidate stabilization conditions of copper ions in Cu-ZSM-5 zeolites as isolated Cu2+ ions, chain copper oxide structures and square-plain oxide clusters. The ability of copper ions for reduction and reoxidation in the chain structures may be responsible for the catalytic activity of Cu-ZSM-5. These transformations of copper ions are accompanied by the observation of intervalence transitions Cu2+–Cu+ and CTLM of the chain structures in the UV–vis spectra. 相似文献
This paper presents the design and practical hardware implementation of optimal neurocontrollers that replace the conventional automatic voltage regulator (AVR) and the turbine governor of turbogenerators on multimachine power systems. The neurocontroller design uses a powerful technique of the adaptive critic design (ACD) family called dual heuristic programming (DHP). The DHP neurocontrollers' training and testing are implemented on the Innovative Integration M67 card consisting of the TMS320C6701 processor. The measured results show that the DHP neurocontrollers are robust and their performance does not degrade unlike the conventional controllers even when a power system stabilizer (PSS) is included, for changes in system operating conditions and configurations. This paper also shows that it is possible to design and implement optimal neurocontrollers for multiple turbogenerators in real time, without having to do continually online training of the neural networks, thus avoiding risks of instability. 相似文献
During experiments on the MSL-1 (first microgravity science laboratory) mission of the space shuttle (STS-83 and STS-94, April
and July 1997), a droplet of palladium-silicon alloy was electromagnetically levitated for viscosity measurements. For the
nondeforming droplet, the resultant magnetohydrodynamic (MHD) flow inside the drop can be inferred from motion of impurity
particulates on the surface. In the experiments, subsequent to melting, Joule heating produces a continuous reduction of viscosity
of the fluid resulting in an acceleration of the flow with time. These observations indicate formation of a pair of co-rotating
toroidal flow structures inside the spheroidal drop that undergo flow instabilities. As the fluid temperature rises, the amplitude
of the secondary flow increases, and beyond a point, the tracers exhibit noncoherent chaotic motion signifying emergence of
turbulence inside the drop. Assuming that the observed laminar-turbulent transition is shear-layer type, the internal structure
of the toroidal loops is used to develop a semiempirical correlation for the onset of turbulence. Our calculations indicate
that the suggested correlation is in modest agreement with the experimental data, with the transition occurring at a Reynolds
number of 600. 相似文献
The influence of changes in load conditions of the generator-transformer unit on the operating conditions of the 100% ground-fault protection of the generator stator winding based on the third-harmonic voltages was analyzed. The analyzed stator ground-fault protection system is by ratio of the voltages third harmonic in generator neutral and at the generator terminals. The third-harmonic voltages were determined on the base of the experimental tests (measurements) run in real conditions at changes in active and reactive load conditions of the generator. It was found that mainly the generator active load influences the voltage feeding the measuring element of ground-fault protection. Therefore, determining operating conditions of ground-fault protection the influence of the generator active and reactive load should be deeply considered. This can ensure the proper operation of the ground-fault protection based on the voltage third harmonics in the whole range of the changes in generator load. Considering the influence of changes in generator load on the third-harmonic voltages (feeding measuring element of the protection system) will allow eliminating irregular generator tripping as a result of unselective operation of these protections. 相似文献
We propose a model that enables software developers to systematically evaluate and compare all possible alternative reuse scenarios. The model supports the clear identification of the basic operations involved and associates a cost component with each basic operation in a focused and precise way. The model is a practical tool that assists developers to weigh and evaluate different reuse scenarios, based on accumulated organizational data, and then to decide which option to select in a given situation. The model is currently being used at six different companies for cost-benefit analysis of alternative reuse scenarios; we give a case study that illustrates how it has been used in practice. 相似文献