Based on generalization and analysis of instructions and guidelines for therapeutical and prophylactic diets of workers, ways of its optimization were proposed, by using bifide-containing acid dairy products as a preventive agent against possible occupational diseases caused by occupational factors. 相似文献
This study investigates the phenotype of turbulent (Re = 5,200) and laminar (Re = 2,000) flow-generated Pseudomonas fluorescens biofilms. Three P. fluorescens strains, the type strain ATCC 13525 and two strains isolated from an industrial processing plant, D3-348 and D3-350, were used throughout this study. The isolated strains were used to form single and binary biofilms. The biofilm physiology (metabolic activity, cellular density, mass, extracellular polymeric substances, structural characteristics and outer membrane proteins [OMP] expression) was compared. The results indicate that, for every situation, turbulent flow-generated biofilms were more active (p < 0.05), had more mass per cm(2) (p < 0.05), a higher cellular density (p < 0.05), distinct morphology, similar matrix proteins (p > 0.1) and identical (isolated strains -single and binary biofilms) and higher (type strain) matrix polysaccharides contents (p < 0.05) than laminar flow-generated biofilms. Flow-generated biofilms formed by the type strain revealed a considerably higher cellular density and amount of matrix polysaccharides than single and binary biofilms formed by the isolated strains (p < 0.05). Similar OMP expression was detected for the several single strains and for the binary situation, not dependent on the hydrodynamic conditions. Binary biofilms revealed an equal coexistence of the isolated strains with apparent neutral interactions. In summary, the biofilms formed by the type strain represent, apparently, the worst situation in a context of control. The results obtained clearly illustrate the importance of considering strain variation and hydrodynamics in biofilm development, and complement previous studies which have focused on physical aspects of structural and density differences. 相似文献
1. We investigated the effect of exercise on plasma adrenomedullin, atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) concentrations and studied the relationship between these peptides and haemodynamic parameters in nine patients with old myocardial infarction (MI) and in eight normal subjects. 2. The exercise protocol consisted of two fixed work loads (40 and 80 W) for 4 min each and venous blood samples were taken at rest, during each exercise stage and after exercise while monitoring the mean arterial pressure (MAP) and heart rate (HR). In MI, pulmonary arterial pressure (PAP), pulmonary capillary wedge pressure (PCWP), left ventricular end-diastolic pressure (LVEDP) and cardiac output (CO) were measured throughout exercise. 3. Adrenomedullin levels did not significantly increase with exercise. Adrenomedullin levels correlated with PAP and PCWP at rest (P < 0.05). Atrial natriuretic peptide levels correlated with PAP, PCWP and LVEDP throughout exercise (P < 0.05) but, on multiple regression analysis, PCWP correlated only with ANP (P < 0.01). Brain natriuretic peptide levels correlated with LVEDP throughout exercise (P < 0.01) and its increment correlated closely with basal BNP levels at rest (P < 0.01). 4. These results suggest that adrenomedullin does not respond to the acute haemodynamic changes of exercise, whereas ANP responds to it and PCWP is the major stimulus factor. Brain natriuretic peptide responds to exercise in proportion to the basal synthesis of BNP in patients with left ventricular dysfunction and LVEDP may play a role in increasing BNP during exercise. 相似文献
The complete set of measurements that could ever be used by a passive 3D vision algorithm is the plenoptic function or light-field. We give a concise characterization of when the light-field of a Lambertian scene uniquely determines its shape and, conversely, when the shape is inherently ambiguous. In particular, we show that stereo computed from the light-field is ambiguous if and only if the scene is radiating light of a constant intensity (and color, etc.) over an extended region. 相似文献
OBJECTIVE: To know the variability in the interpretation (normal/pathological) of posteroanterior view chest radiograph and the associated factors between a medical primary care community and a Gold Standard (GS) from 3 reference radiologists. DESIGN: Crossover study. SETTING: Primary care. Teaching health centers of Elche. METHODS: Interobserver percentage agreement (IPA) and Kappa statistic (K) were used to analyse the interobserver agreement (IA) between the GS and every of the participants in interpretation of 100 radiographs. Intraobserver variability was assessed with a second review. Using uni and multivariant analysis some possibly associated factors were studied. RESULTS: Overall IPA and K were 71.3% (CI 95%: 69.2-73.3) and 0.41 (CI 95%: 0.36-0.46) respectively. Time employed in radiographs reading and time passed after medicine studies finished were independently and significantly associated to higher and lower interobserver agreement results respectively, whereas recent professional experience, permanent job and age were not associated. Professional training is the variable that most explain the inter and intraobserver variability. CONCLUSIONS: Overall IA is acceptable. The IA showed by the participants trained under the MIR system is good but the IA achieved by the rest of participants is not acceptable. It is necessary a training which increase the clinical competence, as it does MIR training. 相似文献
The postpartum period is an ideal time to begin contraception, as women are more highly motivated to adopt contraception at this time and it is convenient for both patients and service providers. For intrauterine device (IUD) contraception, this period offers other advantages, such as ease of insertion and minimal adverse impacts on breastfeeding. Among early studies, most postpartum insertions were performed anywhere from a few hours to seven days or more after delivery, and retention of the IUD in the uterus was poor. Since the 1970s, immediate postplacental insertion (IPPI), i.e., IUD insertion performed within 10 minutes after placental delivery, has been advocated, and fairly, low expulsion rates have been reported. Up to now, IPPI has not been widely accepted in clinics because its expulsion rate still appears to be higher than that of interval insertion. In order to further study IPPI and perfect this contraceptive technique, it is essential to comprehensively review IPPI results and compare the Chinese experience with that of the rest of the world. 相似文献
This paper describes the development of an expert system in gearing design application. The knowledge in this design field is vast and involves selection of appropriate data from large amounts of engineering standards data available in engineering catalogues and design handbooks. Experts very oftens have different opinions in determining the design solution. The theme of the work is to organise, systemise, conserve and spread this knowledge relating to gearing design and configuration.
There is a large number of design parameters involved in gearing design. The design of gears also requires an iterative approach to optimize these design parameters that govern the kinematic, as well as the strength performance. Owing to the complex combinations of these aspects, conventional design office practice tends to become complicated and time consuming. Hence, in this piece of work, attempts are made to formulate a design system capable of designing a required type of gear and its configuration under a specified set of working conditions.
The main features of the expert gearing design system are the use of semantic nets in representing the objects, a frame-based data acquisition and representation system, and production rules in representing the domain-specific knowledge base. The system provides a very user-friendly interface through the use of an expert system development tool Prolog. While Prolog is used to set up the various databases and the inference engine, the detail gear design calculations are performed by C. It is found that the communication between these two language media is excellent in terms of performance and efficiency. 相似文献