This paper studies the stability analysis problem for time-varying delay systems. An appropriate Lyapunov-Krasovskii functional (LKF) is constructed where its derivative is a quadratic polynomial function of the delay. A novel negative condition of the mentioned quadratic function with two variable parameters is developed to ensure that the LKF derivative is negative, reducing conservatism on some similar results. Besides, an extended version of Bessel-Legendre inequality is introduced to be employed in the stability analysis of time-varying delay systems. Then, some stability criteria with less conservatism are derived for two kinds of the time-varying delay. Finally, the effectiveness of the proposed stability criteria is demonstrated through three examples.
The performance of an attached growth wastewater treatment process was investigated in an effort to improve nitrogen removal
efficiency. Recycled Yakult (lactic acid fermentation drink) bottles made of polystyrene were used as a biofilm media. The
use of Yakult bottles as a biofilm media has been attempted by numerous researchers in Japan for the removal of solids and
organics. However, these studies focused only on the removal of solids and organics. This study extended their application
to the removal of nitrogen for domestic sewage treatment. Yakult media was placed in a reactor with 70% apparent reactor volume
in a conventional A/O process. The bottom of the Yakult media was removed, and randomly filled Yakult media were effectively
able to reduce the flow in tanks, resulting in an increase in the contact time between pollutants and microorganisms. With
higher HRT, the nitrogen removal efficiency was increased by up to 83% with 12 hr of HRT. Nitrification appeared to be the
limiting factor of nitrogen removal at an HRT that is less than 12 hr, indicating that the Yakult process requires more retention
time to achieve nitrification compared to other biofilm processes. The removal efficiencies of organics and solids were high
regardless of the change of operational parameters.
This article is based on a presentation in “The 7th Korea-China Workshop On Advanced Materials” organized by the Korea-China
Advanced Materials Cooperation Center and the China-Korea Advanced Materials Cooperation Center, held at Ramada Plaza Jeju
Hotel, Jeju Island, Korea on August 24–27, 2003. 相似文献
The Cd−Zn system has been thermodynamically reassessed with the CALPHAD method by combining more recent experimental data,
in particular the activities of zinc in the liquid phase. A good agreement is obtained between the calculated and experimental
thermodynamic parameters as well asphase boundaries. 相似文献
The electromigration behavior of low-melting temperature Sn-58Bi (in wt%) solder joints was investigated with a high current density between 3 and 4.5 × 103 A/cm2 between 80 and 110 °C. In order to analyze the impact of various substrate metallizations on the electromigration performance of the Sn-58Bi joint, we used representative substrate metallizations including electroless nickel immersion gold (ENIG), electroless nickel electroless palladium immersion gold (ENEPIG), and organic solderability preservatives (OSP). As the applied current density increased, the time to failure (TTF) for electromigration decreased regardless of the temperature or substrate metallizations. In addition, the TTF slightly decreased with increasing temperature. The substrate metallization significantly affected the TTF for the electromigration behavior of the Sn-58Bi solder joints. The substrate metallizations for electromigration performance of the Sn-58Bi solder are ranked in the following order: OSP-Cu, ENEPIG, and ENIG. Due to the polarity effect, current stressing enhanced the fast growth of intermetallic compounds (IMCs) at the anode interface. Cracks occurred at the Ni3Sn4 + Ni3P IMC/Cu interfaces on the cathode sides in the Sn-58Bi/ENIG joint and the Sn-58Bi/ENEPIG joint; this was caused by the complete consumption of the Ni(P) layer. Alternatively, failure occurred via deformation of the bulk solder in the Sn-58Bi/OSP-Cu joint. The experimental results confirmed that the electromigration reliability of the Sn-58Bi/OSP-Cu joint was superior to those of the Sn-58Bi/ENIG or Sn-58Bi/ENEPIG joints. 相似文献
To make health care more responsive to patient needs, insight into patient priorities is needed. A systematic literature review, using electronic and manual searches, was made of studies on patient priorities with regard to primary health care. Data-extraction was performed by two researchers, followed by systematic analyses of study features. 57 studies were included. The aspects of care and methods used showed a wide variation. Aspects most often included were "informativeness", "humaneness" and "competence/accuracy". Based on an analysis of 19 studies, the following aspects were seen by patients as most important in more than 50% of the studies that included them: "humaneness", "competence/accuracy", "patients' involvement in decisions", "time for care", "other aspects of availability/accessibility", "informativeness", "exploring patients' needs", "other aspects of relation and communication" and "availability of special services". 相似文献