全文获取类型
收费全文 | 223篇 |
免费 | 18篇 |
国内免费 | 3篇 |
专业分类
电工技术 | 7篇 |
化学工业 | 43篇 |
金属工艺 | 5篇 |
机械仪表 | 9篇 |
建筑科学 | 15篇 |
能源动力 | 12篇 |
轻工业 | 21篇 |
水利工程 | 6篇 |
石油天然气 | 10篇 |
无线电 | 17篇 |
一般工业技术 | 54篇 |
冶金工业 | 4篇 |
原子能技术 | 1篇 |
自动化技术 | 40篇 |
出版年
2023年 | 5篇 |
2022年 | 9篇 |
2021年 | 11篇 |
2020年 | 11篇 |
2019年 | 11篇 |
2018年 | 15篇 |
2017年 | 21篇 |
2016年 | 19篇 |
2015年 | 14篇 |
2014年 | 19篇 |
2013年 | 33篇 |
2012年 | 16篇 |
2011年 | 17篇 |
2010年 | 14篇 |
2009年 | 11篇 |
2008年 | 4篇 |
2007年 | 3篇 |
2006年 | 2篇 |
2005年 | 3篇 |
2004年 | 3篇 |
1998年 | 3篇 |
排序方式: 共有244条查询结果,搜索用时 15 毫秒
11.
Ali Zangeneh Shahram Jadid Ashkan Rahimi-Kian 《Electrical Engineering (Archiv fur Elektrotechnik)》2010,91(7):369-382
Decision making under uncertainty is a difficult task in most areas. The distributed generation expansion planning is certainly
one of the problems where it is difficult to find an optimal solution for, due to the existence of various uncertain parameters
that affect the optimal solution. This paper presents a distributed generation planning strategy based on the multi-objective
decision making (MODM) approach under uncertainties. The proposed strategy achieves a Pareto set of locations, sizes, and
typical types, for new DG installations in a case-study power network (as the result of a multi-objective optimization). The
technical constraints of DG units are also considered in the MODM process. The effects of the uncertain parameters on choosing
the best plan(s) are considered using robustness, flexibility, and risk exposure attributes. This aim is performed based on
a composite index which is weighted sum of the three mentioned attributes. This paper considers four categories of uncertain
parameters including the peak loading factor, electricity market price, and investment and operating costs for the DG long-term
planning. 相似文献
12.
Emily B. Button Andrew S. Mitchell Marcia M. Domingos Jessica H.-J. Chung Ryan M. Bradley Ashkan Hashemi Phillip M. Marvyn Ashley C. Patterson Ken D. Stark Joe Quadrilatero Robin E. Duncan 《Lipids》2014,49(4):305-316
Neuroinflammation is a component of age-related neurodegenerative diseases and cognitive decline. Saturated (SFA) and monounsaturated (MUFA) fatty acids are bioactive molecules that may play different extrinsic and intrinsic roles in neuroinflammation, serving as exogenous ligands for cellular receptors, or endogenous components of cell structural, energetic and signaling pathways. We determined the fatty acyl profile of BV2 microglial cells before and after acute activation with lipopolysaccharide (LPS). We also investigated the effect of SFA and MUFA pretreatment on the production of an invasive, neurotoxic phenotype in BV2 cells. Acute activation of BV2 microglia resulted in an increase in the relative content of SFA (12:0, 16:0, 18:0, 20:0, 22:0, and 24:0 increased significantly), and a relative decrease in the content of MUFA (16:1n7, 18:1n7, 18:1n9, 20:1n9, 24:1n9 decreased significantly). In agreement, the major stearoyl-CoA desaturase (SCD) isoform in BV2 cells, SCD2, was significantly down-regulated by LPS. We next treated cells with SFA (16:0 or 18:0) or MUFA (16:1n7 or 18:1n9), and found that levels of secreted IL6 were increased, as was secreted MMP9-mediated proteolytic activity. To test the functional significance, we treated SH-SY5Y neuronal cells with conditioned medium from BV2 cells pretreated with fatty acids, and found a small but significant induction of cell death. Our findings suggest differential intrinsic roles for SFA and MUFA in activated microglial cells, but similar extrinsic roles for these fatty acid species in inducing activation. Expansion of SFA is important during microglial cell activation, but either supplemental SFA or MUFA may contribute to chronic low-grade neuroinflammation. 相似文献
13.
The effect of heat-treatment on foaming properties of ostrich albumen was investigated. At pH 7.5, coagulation of ovotransferrin (OT) resulted in minimum foaming capacity (FC) and maximum foam density (FD). While both exposure of sulfhydryl groups of ovalbumin (OV) and OT-OV interactions improved FC at lower pH, neither of them had beneficial effect on FC at pH 9. At pH 9, FC and FD were mildly affected by heat-treatment because of less aggregation of OT, then FC decreased due to covalent aggregates composed of ovomucin and OV, but at higher temperatures, higher level of OV unfolding resulted in enhanced FC. 相似文献
14.
Ehsan Soleimani-Nasab Mehrdad Ardebilipour Ashkan Kalantari Behrad Mahboobi 《AEUE-International Journal of Electronics and Communications》2013,67(1):45-57
In this paper, we present the performance of multi-antenna selective combining decode-and-forward (SC-DF) relay networks over independent but non-identical Nakagami-m fading channels with imperfect channel estimation. The outage probability, moment generating function (MGF) and symbol error probability (SEP) will be derived in closed-form using the SNR statistical characteristics. To make the analysis trackable, we have derived the MGF and SEP for integer values of fading severity, m. Also, to make the relations more simple, we develop high signal to noise ratio (SNR) analysis for the performance metrics of our system. Subsequently, we propose optimal and adaptive power allocation algorithms along with the equal power allocation method. Finally, for comparison with analytical formulas, we perform some Monte-Carlo simulations. 相似文献
15.
Ashkan Javaherian Amir Movafeghi Reza Faghihi Effat Yahaghi 《Journal of Visual Communication and Image Representation》2013,24(7):773-785
This study proposes a versatile criterion for estimating quality of images in electrical impedance tomography. The point spread function (PSF) is calculated throughout the domain based on the scattering of energy as responses to a small anomaly spirally moved from the centre to the boundary. The proposed PSF is a measure of weighted spatial variance (WSV) of the conductivity over the whole domain. For each element, the weighting factor is a normalized multiplication of the area of that element by its square intensity. The WSV collectively incorporates all image attributes, i.e., spatial resolution, artifact, amplitude response, positioning error and shape deformation. The location of artifacts, which significantly influences reconstructed images in reality, is taken into account as well. The results illustrate that the proposed measure is more tolerant than existing criteria in evaluating performance of EIT systems in both theory and practice. 相似文献
16.
Farhad Garavand Ashkan Madadlou Sohrab Moini 《International Journal of Food Properties》2017,20(1):19-29
The phytochemicals content and radical scavenging activity of pistachio (Pistacia vera L.) hull extract obtained by different solvents (water, ethanol, and butanol) were measured and compared. Water was selected as superior solvent. Ultrasound-assisted aqueous extraction of the hull by power ultrasound (35 kHz) was more efficient in ascending the phytochemicals content than the sonochemical ultrasonication (130 kHz). High-performance liquid chromatography-mass spectrometry showed increased amounts of vanillic acid, p-coumaric acid, naringenin, and catechin in ultrasound-assisted extracts. Post-extraction sonication declined significantly the phenolics amount and antioxidant property of the aqueous extract. Microwave-assisted extraction increased the phenolics and flavonoids content at extract in a power-dependent trend. 相似文献
17.
Ashkan Heidarkhan Tehrani Pooya Davari Sanjleena Singh Adekunle Oloyede 《Journal of materials science. Materials in medicine》2014,25(4):953-964
This paper investigates the potential of pulsed power to sterilize hard and soft tissues and its impact on their physico-mechanical properties. It hypothesizes that pulsed plasma can sterilize both vascular and avascular tissues and the transitive layers in between without deleterious effects on their functional characteristics. Cartilage/bone laminate was chosen as a model to demonstrate the concept, treated at low temperature, at atmospheric pressure, in short durations and in buffered environment using a purposed-built pulsed power unit. Input voltage and time of exposure were assigned as controlling parameters in a full factorial design of experiment to determine physical and mechanical alteration pre- and post-treatment. The results demonstrated that, discharges of 11 kV sterilized samples in 45 s, reducing intrinsic elastic modules from 1.4 ± 0.9 to 0.9 ± 0.6 MPa. There was a decrease of 14.1 % in stiffness and 27.8 % in elastic-strain energy for the top quartile. Mechanical impairment was directly proportional to input voltage (P value < 0.05). Bacterial inactivation was proportional to treatment time for input voltages above 32 V (P < 0.001; R Sq = 0.98). Thermal analysis revealed that helix-coil transition decelerated with exposure time and collagen fibrils were destabilized as denaturation enthalpy reduced by 200 μV. We concluded by presenting a safe operating threshold for pulsed power plasma as a feasible protocol for effective sterilization of connective tissues with varying level of loss in mechanical robustness which we argue to be acceptable in certain medical and tissue engineering application. 相似文献
18.
Mozhgan Chimeh Paul Cockshott Susanne B. Oehler Ashkan Tousimojarad Tian Xu 《Concurrency and Computation》2015,27(17):5060-5075
Intel's XeonPhi is a highly parallel x86 architecture chip made by Intel. It has a number of novel features which make it a particularly challenging target for the compiler writer. This paper describes the techniques used to port the Glasgow Vector Pascal Compiler to this architecture and assess its performance by comparisons of the XeonPhi with 3 other machines running the same algorithms. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
19.
Hassan Elmkhah Mohammad-Rashed Mohammadi Maryam Molaei Ashkan Zolriasatein Mostafa Meghdari Arash Fattah-alhosseini 《International Journal of Applied Ceramic Technology》2022,19(6):3072-3083
This study aims to investigate how the predeposition machining processes such as magnetic grinding, turning machining, and wire electrical discharge machining can influence the surface properties including electrochemical and tribological behavior of TiCrN nanostructured coating applied on Mo40 steel substrate. A physical vapor deposition technique using cathodic arc evaporation was used to apply the coating. The crystallographic phases and the microstructure of the coating were studied by X-ray diffraction and scanning electron microscope, respectively. Rockwell-C, electrochemical impedance spectroscopy and potentiodynamic polarization, and pin-on-disk wear tests were employed to evaluate the adhesion strength, corrosion behavior, and tribological property of specimens, respectively. The electrochemical results after 24 h of exposure to 3.5 wt% NaCl solution showed that TiCrN coating pretreated with a turning process with polarization resistance of about 3525.32 Ω.cm2 had the best corrosion resistance among all specimens. This was because of the improvement of the smoothness, surface quality, and adhesion after the turning process. On the other, the friction coefficient of the grounded sample is less than that of other ones. This is probably due to its higher adhesion strength and higher surface smoothness. 相似文献
20.
Effect of mixer geometry and operating conditions on flow mixing of shear thinning fluids with yield stress 下载免费PDF全文
Jaime Sossa‐Echeverria Fariborz Taghipour 《American Institute of Chemical Engineers》2014,60(3):1156-1167
Flow mixing of a non‐Newtonian fluid in a stirred tank equipped with a side‐entry impeller was observed using particle image velocimetry (PIV). The effects of some geometrical parameters including the mixer shape and impeller type and position on the flow pattern were studied on velocity fields obtained at different locations inside the mixing domain. The different flow structures revealed that the ratio of inertial and viscous forces largely defines the flow pattern. Dead zones were observed inside the tank due to the rheological properties of the fluid. The size of the dynamic regions and the average velocity near the impeller were enhanced by increasing the suction area. Likewise, large pitch ratios were found to improve the active mixing zone and the axial discharge. Curves for the power and pumping numbers are reported for different axial flow impellers. © 2013 American Institute of Chemical Engineers AIChE J, 60: 1156–1167, 2014 相似文献