Underground construction is notorious for high cost and time overruns. This is probably inherent in the nature of the work, which usually involves high risks on the part of both the employer and the contractor, in view of the extent of the uncertainties with regard to such factors as geology, appropriate design and performance. The main civil works constructed for South Africa's Palmiet Pumped Storage Scheme between 1983 and 1987 have demonstrated that with early identification and proper management of the risks and costs, the value of cost and time overruns can be curtailed to a very large extent. This paper describes broadly the process adopted on the project, focusing in particular on the successful management at Palmiet of the financial risks pertaining to the cost of the contractor's overheads, establishment, supervision and plant in a contract that was known to be subject to variations, extensions and delays. This was achieved by appropriate scheduling, provisions for payment and on-site management of these cost items, usually described broadly as the Preliminary and General (P & G) Items. These items accounted for 34% of the value of the contract. 相似文献
Two approximate yield criteria are proposed for reinforced concrete cylindrical shell element. Three lower bound solutions are developed for cylindrical shell roofs with free longitudinal edges. Two shells with different geometric parameters are analysed. Elastic analysis is also done at working load. Graphs are presented to show the variation of stress resultants at critical sections. 相似文献
Water levels in tidal rivers are subject to the influence of both fluvial and tidal factors. The interaction between these factors is rendered more complex in regions affected by typhoons, which typically result in the combined occurrence of heavy rainfall and high sea levels. Previous studies have outlined an analytical approach for calculating design water levels based on dividing the fluvial and tidal series into a typhoon and a non-typhoon component. This paper illustrates the steps involved in the analytical approach and describes its application to drainage basins in Hong Kong. The approach provides a practical means for calculating design water levels, and is recommended for final design purposes. The results of using the full analysis may be approximated by using a sub-set of analytical results, and should prove satisfactory for the purposes of outline design. 相似文献
Bulletin of Engineering Geology and the Environment - Precambrian layered rocks consisting of quartzites, phyllites and metagreywackes of the Aravallis having a large variation in thickness,... 相似文献
Weak base phenol formaldehyde anion exchange resins were found to have an excellent capacity for removing the anionic organic species benzenesulfonate (BS), p-toluenesulfonate (PTS) and dodecylbenzenesulfonate (DBS) from pH 2 and 4 solutions. The capacity for DBS was generally greater than that of activated carbon and significantly greater than that of a polystyrene-divinylbenzene resin with no ion exchange functional groups. The maximum capacity of the weak base resins appeared to be limited by the exchange capacity of the resin. The mechanism of removal was strongly indicated as being either ion exchange at the amine functional groups in the acid form, or uptake of a proton by the amine groups in the free base form with the organic anion as the associated counter ion. Increasing concentrations of Cl− decreased the amount of organic anion that could be sorbed.The swelling of one of the resins, Duolite A-7, also had a marked effect on its sorption capacity. The pores of the acid chloride or acid organic anion form of the resin were apparently larger than those of the free base form; thus, as conversion of the resin to the acid form took place, a greater amount of uptake was observed. The effect of swelling on the capacity of Duolite S-37 was much less, apparently owing to its larger pore structure, but its capacity for DBS at low pH was lower than that for A-7 because of its lower nitrogen content. Also, BS and DBS were easily removed from the weak base resins by washing them with NaOH. Four bed volumes of 1 m NaOH gave essentially complete regeneration of BS saturated A-7. 相似文献
ABSTRACT The main purpose of this study is to analyse the phenomenon of pool boiling in water over a horizontally placed copper tube heater of 28?mm diameter. The experiment has been carried out to observe the bubble growth and departure characteristics for the heat flux range up to 40,000?W/m2. The entire process is being recorded by a digital camera at different time intervals. The measured parameters have been used to determine the initial layer thickness, macro layer thickness and critical heat flux and validated with models proposed in the literature. 相似文献
The size and structure of flocs during floc formation were monitored for various coagulation mechanisms. Two distinctive mechanisms, namely, enmeshment and electrostatic patch, govern the dynamics of kaolin particles coagulation by polyaluminum chloride (PACl). They were investigated by small angle static light scattering (SASLS) and solid-state 27Al NMR. In addition, a novel wet SEM (WSEM) was used in-situ to image the morphology of the aggregate in aqueous solution. Synthetic suspended particles were coagulated by two PACl products, a commercial product (PACl) and one laboratory product (PACl-E). The PACl-E contained more than 60% Al13 while the PACl contained only 7% Al13, with large percentage of colloidal Al. For coagulation by PACl at neutral pH and high dosage where the strong repulsion between particles occurs, the enmeshment ruled by reaction-limited aggregation (RLA) results in larger sweep flocs as well as higher fractal dimensional structure. For coagulation by PACl-E at alkaline pH and low dosage, the flocs were coagulated predominately by electrostatic patch with Al13 aggregates. At such condition, it is likely that diffusion-limited aggregation (DLA) predominately rule PACl-E coagulation. The fractal dimension (Ds) values of PACl and PACl-E flocs formed at enmeshment and electrostatic patch increased with dosage, respectively. When breakage of flocs occurs, the breakage rate of PACl-E flocs is slower than that of sweep flocs. By WSEM imaging, the adsorption of spherical Al precipitates onto the particles was observed to form sweep flocs with a rough and ragged contour, while the PACl-E flocs were formed with a smooth and glossy structure. 相似文献
Well over a million fire detectors are currently in use in the Federal Republic of Germany. Provided they are correctly installed and efficiently maintained, they detect fires reliably at a very early stage. At the present time, the false alarm rate equals about 1% of the number of installed detectors per annum. This false alarm rate must be at least proportionately reduced as further detectors are installed.
Since it is scarcely possible to improve tried-and-tested detector designs, the employment of higher-grade detector signal processing methods suggests itself.
However, ‘more intelligent’ detector signal processing using microprocessors calls for an entirely new fire detection system structure: detectors which independently ‘decide’ whether an alarm criterion is met and then initiate an alarm are replaced by sensors which continuously transmit their measured values to the ‘intelligence’ panel for evaluation. Passive panels which simply receive alarm signals from activated detectors and indicate these or transmit them to the fire brigade are replaced by active processors using permanently improved algorithms for the detection of real fires.
A structural change of this type is possible provided the positive — and the customary — characteristics of the conventional technique are not lost, viz. two-wire lines between detector and panel, simple installation and handling, easy detector replaceability, low cost, etc.
The pulse detector technology is described in detail; it combines the simplicity of conventional fire detection systems with new characteristics, e.g. identification of individual detectors, permanent functional check of all connected detectors, automatic notification of maintenance requirement prior to a slowly developing fault (e.g. such as that caused by corrosion or contamination), uniform response sensitivity unaffected by drifting from the operating points of the detectors and, above all, greater protection against false alarms. 相似文献
What are the effects of flame behavior of a number of fires burning in close proximity to one another? The results of measurements of burning rates, heat feedback, flame height, and flame trailing are reported for fires involving liquid pools. 相似文献