The deletion of nine residues from the C-terminus of the bacterialchloramphenicol acetyltransferase (CAT) results in depositionof the mutant protein in cytoplasmic inclusion bodies and lossof chloramphenicol resistance in Escherichia coli. This foldingdefect is relieved by C-terminal fusion of the polypeptide withas few as two residues. Based on these observations, efficientpositive selection for the cloning of DNA fragments has beendemonstrated. The cloning vector encodes a C-terminally truncatedCAT protein. Restriction sites in front of the stop codon allowthe insertion of target DNA, resulting in the production ofproperly folded CAT fusion proteins and regained chloramphenicolresistance. The positive selection of recombinants is accomplishedby growth of transformants on chloramphenicol-containing agarplates. The method appears particularly convenient for the cloningof DNA fragments amplified by the PCR because minimal informationto restore CAT folding can be included in the primers. The cloningof random sequences shows that the folding defect can be relievedby fusion to a wide variety of peptides, providing great flexibilityto the positive selection system. This vector may also contributeto the determination of the role of the C-terminus in CAT folding. 相似文献
Carboxyl-terminated butadiene-acrylonitrile-rubber decreases modulus and yield stress of the studied epoxy but increases fracture toughness. The addition of glass bead compensates for the loss in modulus but has little effect on yield stress. However, it significantly contributes to the fracture toughness by providing additional mechanisms for toughening of both the unmodified and rubber-modified epoxy. For the toughened epoxies studied, fracture surfaces gave only limited information on fracture mechanisms since significant energy absorption also occurs in the material below the fracture surface. Suggestions for suitable material compositions for fiber composite matrices are given. 相似文献
A criterion for determining the maximum spacing between magnetometers for measuring the magnetic field is derived. A two-dimensional (2-D) filter model is employed to determine the maximum spatial frequency component present in the magnetic field that is above the spectral noise level. This maximum frequency component is then sampled at a rate greater than twice per period as indicated by the Nyquist criterion, yielding the required magnetometer spacing. It is shown that the rule-of-thumb employed in current clinical biomagnetic array systems, that the spacing between the coils should be approximately equal to the depth of the source, is adequate when the signal-to-noise power ratio is less than 28.4 (14.5 dB). The analysis also quantitatively demonstrates that reducing the separation between the measurement and source planes has a greater effect on the resolution than decreasing the noise level by the same factor. This result is important for employing high Tc superconductor magnetometers that allow thinner thermal insulating layers at the cost of higher thermal noise 相似文献
α,ω-Methacrylate-terminated poly(1,3-dioxolane)s (polyDXL) were synthesized by cationic ring-opening polymerization of DXL in the presence of methylene-bis(oxyethylmethacrylate) as transfer agent. If the initiator concentration is small compared with the transfer agent concentration, the molecular weights of the polymers are governed by the ratio of the reacted monomer to the reacted transfer agent. The α,ω-methacrylate-terminated polyDXLs obtained undergo free radical polymerization with formation of polyacetal networks. The properties of the networks as function of the molecular weight of the corresponding prepolymers are reported. 相似文献
A novel class of narrow-band tunable wavelength filters is proposed and evaluated. Wavelength selectivity of the proposed filters Is derived from the finite time response of an optical nonlinearity. The nonlinearity is gain saturation in semiconductor optical amplifier structures. The filters are shown to have very narrow passbands tunable over the entire semiconductor gain bandwidth. The key to filter implementation is a device configuration in which the wave-mixing products can be isolated from the amplified inputs. Three integrated optics compatible configurations are considered and shown to have high filter throughputs 34 to 180% and subangstrom bandwidths 相似文献
It is not known whether impaired hematopoiesis noted during human immunodeficiency virus (HIV) infection results from infection of stem/progenitor cells or of cells of the bone marrow microenvironment. Normal adherent primary stromal layers were exposed to HIV to determine which of this mixture of endothelial cells, fibroblasts, and macrophages are susceptible to the virus. Viral p24 in supernatants was noted with monocytotropic HIV-1Ada, HIV-1Ba-L, and HIV-1JR-FL but not with lymphotropic HIV-1LAI nor HIV-1MN strain, and only stromal macrophages expressed the viral antigens. Coculture of the layers with PHA-activated normal lymphocytes failed to rescue lymphotropic virus. No p24 was produced when macrophage-depleted stromal cells were exposed to either HIV-1Ba-L or HIV-1LAI; proviral DNA was then amplified by PCR in cells exposed to either virus, though coculture with lymphocytes rescued only HIV-1Ba-L. Altogether, these data indicate that macrophages are the major targets of HIV in cultured stromal layers. As virus replication in macrophages did not affect the profile of major cytokines involved in regulating hematopoiesis, HIV infection could alter hematopoiesis by other as yet unspecified mechanisms. 相似文献
At GKN, fatigue monitoring of important components has been conducted since 1979. The monitoring methods depend on the mechanisms of damage; quasi-static loads are regarded as well as dynamic loads. The components were selected for monitoring on the basis of a system analysis. The data resulting from monitoring are used to optimise operation mode steadily. Experience shows that the use of monitoring data as input for fatigue assessment is the most realistic and cost-effective way. This fatigue assessment uses global and local sensitivity studies to evaluate the load-stress relation for each component. These relations can be programmed to produce stress vs. time curves. These are processed according to ASME rules to give a realistic fatigue usage. 相似文献
A CEC-funded project has been performed to tackle the problem of producing an advanced Life Monitoring System (LMS) which would calculate the creep and fatigue damage experienced by high temperature pipework components. Four areas were identified where existing Life Monitoring System technology could be improved:
1. 1. the inclusion of creep relaxation
2. 2. the inclusion of external loads on components
3. 3. a more accurate method of calculating thermal stresses due to temperature transients
4. 4. the inclusion of high cycle fatigue terms.
The creep relaxation problem was solved using stress reduction factors in an analytical in-elastic stress calculation. The stress reduction factors were produced for a number of common geometries and materials by means of non-linear finite element analysis. External loads were catered for by producing influence coefficients from in-elastic analysis of the particular piping system and using them to calculate bending moments at critical positions on the pipework from load and displacement measurements made at the convenient points at the pipework. The thermal stress problem was solved by producing a completely new solution based on Green's Function and Fast Fourier transforms. This allowed the thermal stress in a complex component to be calculated from simple non-intrusive thermocouple measurements made on the outside of the component. The high-cycle fatigue problem was dealt with precalculating the fatigue damage associated with standard transients and adding this damage to cumulative total when a transient occurred.
The site testing provided good practical experience and showed up problems which would not otherwise have been detected. 相似文献
The trends in high density interconnection (HDI) multichip module (MCM) techniques that have the potential to reduce interconnection cost and production time are described. The implementation in laminated dielectric (MCM-L) technology of a workstation processor core illustrates current substrate technology capabilities. The design, routing, layout and thermal management of the processor core are described. Thin-film deposited dielectric (MCM-D) technology is discussed as a cost-effective method for future interconnection applications 相似文献
Given the enormous size of the genome and that there are potentially many other types of measurements we need to do to understand it, it has become necessary to pick and choose one's targets to measure because it is still impossible to evaluate the entire genome all at once. What has emerged is a need to have rapidly customizable microarrays. There are two dominant methods to accomplish custom microarray synthesis, Affymetrix-like microarrays manufactured using light projection rather than semiconductor-like masks used by Affymetrix to mass manufacture their GeneChip/sup TM/ arrays now, or the ink-jet printing method employed by Agilent. The manufacture of these custom Affymetrix-like microarrays can now be done on a digital optical chemistry (DOC) machine developed at the University of Texas Southwestern Medical Center, and this method offers much higher feature numbers and feature density than is possible with ink-jet printed arrays. On a microarray, each feature contains a single genetic measurement. The initial DOC prototype has been described in several publications, but that has now led to a second-generation machine. This machine reliably produces a number of arrays daily, has been deployed against a number of biomedical questions, is being used in new ways and has also led to a number of spin-off technologies. 相似文献