An all solid-state Ti:sapphire laser differential absorption lidar transmitter was developed. This all-solid-state laser provides a compact, robust, and highly reliable laser transmitter for potential application in differential absorption lidar measurements of atmospheric ozone. Two compact, high-energy-pulsed, and injection-seeded Ti:sapphire lasers operating at a pulse repetition frequency of 30 Hz and wavelengths of 867 and 900 nm, with M2 of 1.3, have been experimentally demonstrated and their properties compared with model results. The output pulse energy was 115 mJ at 867 nm and 105 mJ at 900 nm, with a slope efficiency of 40% and 32%, respectively. At these energies, the beam quality was good enough so that we were able to achieve 30 mJ of ultraviolet laser output at 289 and 300 nm after frequency tripling with two lithium triborate nonlinear crystals. 相似文献
The pharmacokinetic and mean time tissue distribution parameters, after a single 50-mg/kg dose of quercetin administered as intravenous bolus, oral solution, and oral suspension, were determined using rat as an animal model. Following intravenous administration, the elimination rate constant and the elimination half-life were found to be 0.0062 min-1 and 111 min, respectively. Examining the mean time tissue distribution parameters reflected a strong binding affinity of the drug molecules to both plasma and tissue proteins. In addition, the low permeability rate of drug molecules in the peripheral system was demonstrated. Following the oral administration of the drug, the extent of absorption was greater from solution than from suspension. Moreover, the solution showed a shorter Tmax and a higher Cmax than suspension. The absolute bioavailability for the solution was 0.275 and that for suspension was 0.162. The mean residence time (MRT) and the mean absorption time (MAT) were higher for suspension, reflecting the need for dissolving the drug in order to be absorbed. The mean (in-vivo) dissolution time (MDTin-vivo) was 34.5 min. Thus, an oral quercetin formulation that can readily form a drug solution in the gastrointestinal tract may enhance the absorption of the drug. 相似文献
The advantage of using the genotype of a quantitative trait locus (QTL) in selection schemes of dairy cattle was quantified using stochastic simulation. Three selection plans were studied. In the first plan, young bulls waited for 3 yr until their sisters completed a lactation and then were evaluated and selected based on an animal model. In a second plan, young bulls waited for 5 yr until their daughters completed a lactation. An intermediate 4-yr waiting plan was also studied. Simulation was for 16 yr with overlapping generations. Population and model parameters were proportional to the U.S. Holstein population. The advantage of using a QTL was quantified as the percentage of superiority of QTL-assisted over QTL-free selection using cumulative genetic response. Percentage of superiority was reported for four selection pathways: active sires, young bulls, bull dams, and first lactation cows. A general trend was observed: low superiority in early years of selection that increased to a plateau in later years and then decreased. The superiority of the QTL information was greatest in the 3-yr waiting plan and least in the 4-yr waiting plan. Superiority at plateau for selection pathways ranged from 16 to 26% for the 3-yr waiting plan, from 3 to 12% for the 4-yr waiting plan, and from 5 to 13% for the 5-yr waiting plan. The contribution to selection response attributed to the QTL and the polygenes was quantified. The rate at which the favorable allele approached fixation and the accuracy of predicting breeding values on the percentage of superiority were studied. 相似文献
Adhesively bonded joints are increasingly being used in joining various structural components. Adequate understanding of the behaviour of adhesively bonded joints is necessary to ensure efficiency, safety and reliability of such joints. While several joint configurations, such as the single- and double-lap joints have received considerable consideration, the single-strap joint configuration has received little attention, partly because earlier studies have shown it to be the least efficient.
One of the objectives of this paper is to demonstrate that strap joints can be as efficient as lap joints, as long as they are properly designed. This will be done through a detailed analytical investigation into influence of the parameters that govern peak stresses in the adhesive. The next objective is to produce simple equations by which the design of strap joint could be facilitated in an effective manner. For this, the developed analytical expressions are simplified and shown to provide accurate results. The derived solutions provide better insight into understanding the parameters that most influence the edge forces. 相似文献
Introduction Hyperphosphatemia and cardiovascular mortality are associated particularly with end‐stage renal disease. Available therapeutic strategies (i.e., diet restriction, calcium [or not]‐based phosphate binders, calcimimetics) are associated with extrarenal blood purification. Compartmentalization of phosphate limits its depuration during hemodialysis. Several studies suggest that plasmatic pH is involved in the mobilization of phosphate from intracellular to extracellular compartments. Consequently, the efficiency of modified bicarbonate conductivity to purify blood phosphate was tested. Methods Ten hemodialysis patients with chronic hyperphosphatemia (>2.1 mmol/L) were included in the two three–sessions‐per week periods. Bicarbonate concentration was fixed at 40 mmol/L and 30 mmol/L in the first and second periods, respectively. Phosphate depuration was evaluated by phosphate mobilization clearance (KM). Findings Although bicarbonatemia was lower during the second period (21.0 ± 2.7 vs. 24.4 ± 3.1 mmol/L, P < 0.01), no difference was observed in phosphatemia (2.4 ± 0.5 vs. 2.3 ± 0.4 mmol/L, P = NS). The in‐session variation of phosphate was lower (?1.45 ± 0.42 vs. ?1.58 ± 0.44 mmol/L, P < 0.05) and KM was higher during the second period (82.94 ± 38.00 vs. 69.74 ± 24.48 mL/min, P < 0.05). Discussion The decrease of in‐session phosphate and the increase in KM reflect phosphate refilling during hemodialysis. Thus, modulation of serum bicarbonate may play a role in controlling the phosphate pool. Even though correcting metabolic acidosis during hemodialysis remains important, alkaline excess can impair phosphate mobilization clearance. Clinical trials are needed to test the efficiency and relevance of a strategy where bicarbonatemia is corrected less at the beginning of sessions. 相似文献
A new approach of direct adaptive control of single input single output nonlinear systems in affine form using single-hidden layer neural network (NN) is introduced. In contrast to the algorithms in the literature, the weights adaptation laws are based on the control error and not on the tracking error or its filtered version. Since the control error is being expressed in terms of the NN controller, hence its weights updating laws are obtained via back-propagation concept. A fuzzy inference system (FIS) with heuristically defined rules is introduced to provide an estimate of this error based on the past history of the system behaviour. The stability of the closed loop is studied using Lyapunov theory. A fixed structure is then proposed for the FIS and the design parameters reduce to the parameters of the NN. The method is reproducible and does not require any pre-training of the network weights. 相似文献
In this paper, the equations of motion for a general multi-link inverted pendulum system are derived. Assumptions previously employed to simplify such formulation are removed. The pendulum system is more general and includes nonlinear friction terms to suit various engineering applications. The generalized equations are first developed in the absolute coordinate system using Lagrange's technique, then a simple linear transformation is proposed to obtain the set of nonlinear equations in the DevanitHartenberg coordinate system. The equations of motion for double and triple link inverted pendulum systems are given as examples for such dynamics equations. 相似文献