全文获取类型
收费全文 | 139篇 |
免费 | 7篇 |
国内免费 | 1篇 |
专业分类
电工技术 | 4篇 |
化学工业 | 43篇 |
金属工艺 | 7篇 |
机械仪表 | 1篇 |
建筑科学 | 10篇 |
能源动力 | 2篇 |
轻工业 | 5篇 |
无线电 | 16篇 |
一般工业技术 | 28篇 |
冶金工业 | 3篇 |
原子能技术 | 3篇 |
自动化技术 | 25篇 |
出版年
2023年 | 10篇 |
2022年 | 2篇 |
2021年 | 8篇 |
2020年 | 7篇 |
2019年 | 7篇 |
2018年 | 10篇 |
2017年 | 1篇 |
2016年 | 5篇 |
2015年 | 5篇 |
2014年 | 8篇 |
2013年 | 9篇 |
2012年 | 16篇 |
2011年 | 12篇 |
2010年 | 11篇 |
2009年 | 9篇 |
2008年 | 6篇 |
2007年 | 8篇 |
2006年 | 4篇 |
2005年 | 1篇 |
1995年 | 2篇 |
1994年 | 2篇 |
1993年 | 1篇 |
1992年 | 1篇 |
1984年 | 2篇 |
排序方式: 共有147条查询结果,搜索用时 437 毫秒
11.
The use of patterned media is a new approach proposed to extend the recording densities of hard disk drives beyond 1 Tb/in.2. Bit-patterned media (BPM) overcome the thermal stability problems of conventional media by using single-domain islands for
each bit of recorded information, thereby eliminating the magnetic transition noise (Albrecht et al., Magnetic Recording on
Patterned Media, 2003). Considering steady state conditions, we have transferred the pattern from the disk surface onto the
slider surface and have investigated the pressure generation due to the bit pattern. To reduce the numerical complexity, we
have generated the bit pattern only in the areas of the slider near the trailing edge, where the spacing is small. Cylindrical
protrusions were modeled using very small mesh size on the order of nanometers to obtain the flying characteristics for the
entire slider air bearing surface (ABS) using the “CMRR” finite element Reynolds equation simulator (Duwensee et al., Microsyst
Technol, 2006; Wahl et al., STLE Tribol Trans, 39(1), 1996). The effect of pattern height, pattern diameter, slider skew angle,
and slider pitch angle on flying height of a typical slider is investigated. Numerical results show that the flying height
decreases for a patterned slider and the change in flying height is a function of the pattern height and ratio of the pattern
diameter to the pattern pitch. In comparison to discrete track media, the flying height loss is larger for a patterned slider
disk interface for the same recessed area of pattern. 相似文献
12.
13.
An improved synthetic access for the construction of 4,6,7-trimethylbenzofurans ( B1–B8 ) through the one-electron oxidation of mesityl-substituted enols ( E1–E8 ) is presented. The transformation can be accomplished in good to excellent yields by using various oxidants; i.e. tris(1,10-phenanthroline)iron(III) hexafluorophosphate, FeCl3, Ce(NH4)2(NO3)6, Cu(OTf)2/Cu2O or anodic oxidation. 相似文献
14.
Benedikt Scherger Steffen Wietzke Maik Scheller Nico Vieweg Matthias Wichmann Martin Koch Karin Wiesauer 《Journal of Infrared, Millimeter and Terahertz Waves》2011,32(7):943-951
We investigate different micro-powders that can be used as base materials for THz lenses fabricated by compression molding.
For this application materials with a very weak THz absorbance and low dispersion are required. By measuring the THz absorption
coefficient and refractive index of pellets pressed from the different micro-powders, we identify several materials that are
well suited for the fabrication of compression molded THz lenses (CMLs). In addition, a considerable range of the refractive
index is covered by the samples, which will allow for the fabrication of CMLs with different focal lengths for one and the
same lens design. 相似文献
15.
16.
Abstract
Copper complexes catalyze the reduction of aliphatic and aromatic sulfoxides in the presence of silanes as reducing reagent. The influence of different reaction parameters on the catalytic activity is investigated in detail. The scope and limitations of the described catalyst is demonstrated in the reduction of various sulfoxides. In most cases, high conversion and excellent chemoselectivity are obtained. 相似文献17.
Svetlana S. van Bavel Maik Bärenklau Gijsbertus de With Harald Hoppe Joachim Loos 《Advanced functional materials》2010,20(9):1458-1463
The performance of polymer solar cells (PSC) strongly depends on the 3D morphological organization of the donor and acceptor compounds within the bulk heterojunction active layer. The technique of electron tomography is a powerful tool for studying 3D morphology of the layers composed of poly(3‐hexylthiophene) (P3HT) and a fullerene derivative ([6,6]‐phenyl‐C61‐butyric acid methyl ester; PCBM), especially to quantify the amount and distribution of fibrillar P3HT nanocrystals throughout the volume of the active layer. In this study, electron tomography is used to characterize P3HT/PCBM layers with different blend compositions, both before and after thermal annealing. The power conversion efficiency of the corresponding PSCs is strongly dependent on the overall crystallinity of P3HT and the way P3HT crystals are distributed throughout the thickness of the active layer. 相似文献
18.
Luegmair G Kniesburges S Zimmermann M Sutor A Eysholdt U Döllinger M 《IEEE transactions on medical imaging》2010,29(12):1979-1991
The ability to communicate with our voice can be regarded as the concatenation of the two processes "phonation" and "modulation." These take place in the larynx and palatal and oral region, respectively. During phonation the audible primary voice signal is created by mutual reaction of vocal folds with the exhaled air stream of the lungs. The underlying interactions of masses, fluids and acoustics have yet to be identified and understood. One part of the primary signal's acoustical source are vortex induced vibrations, as e.g., created by the Coand?effect in the air stream. The development of these vorteces is determined by the shape and 3-D movements of the vocal folds in the larynx. Current clinical in vivo research methods for vocal folds do not deliver data of satisfactory quality for fundamental research, e.g., an endoscope is limited to 2-D image information. Based hereupon, a few improved methods have been presented, however delivering only selective 3-D information, either for a single point or a line. This stands in contrast to the 3-D motions of the entire vocal fold surface. More complex imaging methods, such as MRI, do not deliver information in real-time. Thus, it is necessary to develop an easily applicable, more improved examination method, which allows for 3-D data of the vocal folds surfaces to be obtained. We present a method to calibrate a 3-D reconstruction setup including a laser projection system and a high-speed camera. The setup is designed with miniaturization and an in vivo application in mind. The laser projection system generates a divergent grid of 196 laser dots by diffraction gratings. It is calibrated with a planar calibration target through planar homography. In general, the setup allows to reconstruct the topology of a surface at high frame rates (up to 4000 frames per second) and in uncontrollable environments, as e.g., given by the lighting situation (little to no ambient light) and varying texture (e.g., varying grade of reflection) in the human larynx. In particular, this system measures the 3-D vocal fold surface dynamics during phonation. Applied to synthetic data, the calibration is shown to be robust (error approximately 0.5 μm) regarding noise and systematic errors. Experimental data gained with a linear z -stage proved that the system reconstructs the 3-D coordinates of points with an error at approximately 15 μm. The method was applied exemplarily to reconstruct porcine and artificial vocal folds' surfaces during phonation. Local differences such as asymmetry between left and right fold dynamics, as well as global parameters, such as opening and closing speed and maximum displacements, were identified and quantified. 相似文献
19.
20.
Bernstein A Shouakar-Stash O Ebert K Laskov C Hunkeler D Jeannottat S Sakaguchi-Söder K Laaks J Jochmann MA Cretnik S Jager J Haderlein SB Schmidt TC Aravena R Elsner M 《Analytical chemistry》2011,83(20):7624-7634
Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of (37)Cl/(35)Cl instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of δ(37)Cl was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1σ ≈ 0.1‰), to GC/qMS (1σ ≈ 0.2-0.5‰ for Agilent GC/qMS and 1σ ≈ 0.2-0.9‰ for Thermo GC/qMS). Nonetheless, δ(37)Cl values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications. 相似文献