Bulletin of Engineering Geology and the Environment - Soil permeability had to be carefully determined in order to decide whether or not the whole lower reservior (750.000 m2) of the Presenzano... 相似文献
Well over a million fire detectors are currently in use in the Federal Republic of Germany. Provided they are correctly installed and efficiently maintained, they detect fires reliably at a very early stage. At the present time, the false alarm rate equals about 1% of the number of installed detectors per annum. This false alarm rate must be at least proportionately reduced as further detectors are installed.
Since it is scarcely possible to improve tried-and-tested detector designs, the employment of higher-grade detector signal processing methods suggests itself.
However, ‘more intelligent’ detector signal processing using microprocessors calls for an entirely new fire detection system structure: detectors which independently ‘decide’ whether an alarm criterion is met and then initiate an alarm are replaced by sensors which continuously transmit their measured values to the ‘intelligence’ panel for evaluation. Passive panels which simply receive alarm signals from activated detectors and indicate these or transmit them to the fire brigade are replaced by active processors using permanently improved algorithms for the detection of real fires.
A structural change of this type is possible provided the positive — and the customary — characteristics of the conventional technique are not lost, viz. two-wire lines between detector and panel, simple installation and handling, easy detector replaceability, low cost, etc.
The pulse detector technology is described in detail; it combines the simplicity of conventional fire detection systems with new characteristics, e.g. identification of individual detectors, permanent functional check of all connected detectors, automatic notification of maintenance requirement prior to a slowly developing fault (e.g. such as that caused by corrosion or contamination), uniform response sensitivity unaffected by drifting from the operating points of the detectors and, above all, greater protection against false alarms. 相似文献
Nearly 1500 spot urine samples were collected in the winter of 1987-1988 from women of seven farming prefectures located throughout Japan. Samples were analyzed for copper by flameless atomic absorption spectrometry. The copper content of the urine samples (Cu-U) distributed log-normally with a geometric mean (geometric standard deviation) of 36.9 (1.47) micrograms/l after adjustment for the specific gravity of urine of 1.016. The 95% confidence range was 17.1-79.7 micrograms/l. Neither alcohol consumption nor smoking habit affected the Cu-U. A literature survey showed that the observed level appears to be somewhat higher than previously reported values. 相似文献
The Institute of Fire Safety Engineering Research and Technology Centre (FireSERT) at the University of Ulster in Northern Ireland has been a major provider of higher technical fire safety education, fire related research and services to industry for over 20 years. Its internationally recognised research spans the fields of fire dynamics, structural fire engineering, human behaviour in fire and more recently fire (CFD) modelling. Since 1991, it has offered the only PG Dip/MSc Fire Safety Engineering programme in the United Kingdom. In September 2000 FireSERT was the recipient of a £5.7 m Joint Infrastructure Fund (JIF) Award to build new fire safety engineering laboratories on the University's Jordanstown campus. These new facilities unparallel in the University sector in the UK offer greater scope and depth to the FireSERT's research portfolios. The new facilities will be extensively used in support of FireSERT's suite of MSc Fire Safety Engineering and DPhil programmes. This paper presents a brief history of FireSERT and its achievements, together with an update on the new facility, current research themes, taught programmes, research opportunities and visions for the future. 相似文献
Heavy metal concentrations have been determined in maternal and cord blood samples collected from mothers in the age group 20-25 years with full-term neonates (37-40 weeks). The concentrations of Pb, Cd, Cu and Zn were found to be low in cord blood as compared to mother's blood and the ratio between cord blood and maternal blood for the respective elements was found to be approximately 0.80, 0.86, 0.47 and 0.40. On the other hand, the concentrations of Fe and Mg in the mother's blood were found to be lower than those in the cord blood. Prenatal exposure to lead in Mumbai, though low (5.1 microg/dl), is approximately 2-3 times higher than that observed in Canada or Italy. A strong correlation (r = 0.79) between the maternal and cord blood lead levels has been observed during the present study. 相似文献
The content of chlorinated persistent organic pollutants was determined in a total of 44 egg samples from 8 different raptor species collected throughout Norway in the period 1991-1997. The content of 8 chlorinated bornanes, 9 chlorinated pesticides, and 15 polychlorinated biphenyl congeners (PCB) were determined. The highest average concentrations for PCB were found for eggs from White-tailed Sea Eagle and Peregrine Falcon (average sum PCB concentration: 8.9 and 9.1 microg/g wet weight (w.w.), respectively). Merlin and Sparrowhawk eggs were the highest contaminated with chlorinated pesticides (average sum pesticide concentration: 3.0 and 4.3 microg/g w.w.). For the first time, the content of chlorobornanes was determined in Norwegian birds of prey eggs. However, only minor contamination compared to PCBs and conventional chlorinated pesticides was found. The highest sum concentration was determined for White-tailed Sea Eagle eggs (0.09 microg/g w.w.). No chlorobornane contamination was found in Osprey and Merlin eggs. No spatial and regional specific trends or pattern distribution were found for organochlorine contamination in the egg samples analysed. In order to gain information about enantiomer specific bioaccumulation and biotransformation capacity of the organism, enantioselective analyses was performed for the chiral contaminants trans-chlordane, oxy-chlordane and the chlorobornane B9-1679 (Parlar #50). Indications for species-dependent deviation from the racemic distribution (enantiomeric ratio = 1) were found. Peregrine Falcon and Merlin eggs were characterised with an extremely high enantiomeric excess of the (-)-trans-chlordane (enantiomeric ratio (ER) <0.01). For Golden Eagle, Goshawk and Sparrowhawk eggs, the ERs were between 0.1 and 0.22 demonstrating also here that the (-)-trans-chlordane was the most abundant enantiomer. For the distribution of oxy-chlordane and B9-1679 enantiomers no species-dependent differences were found. For all species the ER values between 0.3 and 0.8 were determined. Thus, also for oxy-chlordane and B9-1679, the (-)-enantiomers are the most dominating stereoisomers in the birds of prey eggs analysed. 相似文献
GaN-based ultraviolet-C (UV-C) light emitting diodes (LEDs) are of great interest for water disinfection. They offer significant advantages compared to conventional mercury lamps due to their compact form factor, low power requirements, high efficiency, non-toxicity, and overall robustness. However, despite the significant progress in the performance of semiconductor based UV LEDs that has been achieved in recent years, these devices still suffer from low emission power and relatively short lifetimes. Even the best UV LEDs exhibit external quantum efficiencies of only 1-2%.The objective of this study was to investigate the suitability of GaN-based UV LEDs for water disinfection. The investigation included the evaluation of the performance characteristics of UV LEDs at different operating conditions as well as the design of a UV LED module in view of the requirements for water treatment applications. Bioanalytical testing was conducted using Bacillus subtilis spores as test organism and UV LED modules with emission wavelengths of 269 nm and 282 nm.The results demonstrate the functionality of the developed UV LED disinfection modules. GaN-based UV LEDs effectively inactivated B. subtilis spores during static and flow-through tests applying varying water qualities. The 269 nm LEDs reached a higher level of inactivation than the 282 nm LEDs for the same applied fluence. The lower inactivation achieved by the 282 nm LEDs was compensated by their higher photon flux. First flow-through tests indicate a linear correlation between inactivation and fluence, demonstrating a well designed flow-through reactor. With improved light output and reduced costs, GaN-based UV LEDs can provide a promising alternative for decentralised and mobile water disinfection systems. 相似文献
This paper examines job accessibility impacts of intensive and multiple land-use scenarios in the Netherlands’ Randstad Area for the period 1996–2030. The scenarios involve a heavy increase in the density and diversity of activities around railway stations. Accessibility impacts are examined using location-based accessibility measures and utility-based accessibility benefit measures within a high-resolution land-use/transport interaction modelling framework, taking into account the regional demand for economic activities and possible market responses. It is concluded that extreme concentrations of economic activities at central urban locations well served by public transport are not to be preferred over less heavy concentrations of economic activities at more locations. Heavy concentrations of new firms may firstly repel existing firms in the neighbourhood and secondly result in decreasing marginal returns of accessibility benefits for public transport users. 相似文献
The paper describes experimental tests carried out on three tube-stiffened prolate hemi-ellipsoidal domes under external water pressure.The tubes were stuck to the internal surfaces of these three domes, in their flanks, and the experimental tests showed that the tubes increased the buckling pressures of these domes, especially in one case, when the tube was subjected to an initial internal pressure.All three domes failed by lobar buckling, in their flanks, and showed buckling resistances much larger than similar unstiffened domes. 相似文献