Acta Informatica - Tabular data structures of a relational database, placed in a paged virtual space or in some two-level storage, are discussed. To rearrange, or transpose, those data stored... 相似文献
The performance of MU/SC conversion sleeve produced by bulk metallic glass (Zr55Al10Ni5Cu30) was examined. A precision die-casting method was applied to improve size accuracy. The size accuracy of the conversion sleeve produced by the precision die-casting method was ±1 μm, and optical insertion loss (Li) was less than 0.3 dB for a standard value. The wear resistance of metallic glass is improved by surface oxidation treatment in air at 673 K. The MU/SC conversion sleeve produced from bulk metallic glass has superior characteristics for optical parts. 相似文献
Case-carburizing of helical gears with large helix angles may form too large hardened layers near the tooth width end on the acute angle side (ACUTE-END), and adversely affect the bending fatigue strength. We investigated the bending fatigue strength of casecarburized helical gears with large helix angles up to approximately 40° through a bending fatigue test, hardness test, and residual stress measurement. We found that the case-carburizing formed large hardened layers near ACUTE-END, reduced the compressive residual stress near ACUTE-END, and restricted the improvement of the bending fatigue strength in a meshing state where tooth root stress became large near ACUTE-END. Based on the obtained bending fatigue limits, we revealed that ISO 6336-3:2006 overestimated the rate of increase of the permissible circumferential loads for helix angles exceeding approximately 30°, and ISO/DIS 6336-3:2018 underestimated this rate for helix angles near 30°.
A simple and rapid multiresidue method was developed for the determination of twelve quinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, flumequine, marbofloxacin, nalidixic acid, norfloxacin, ofloxacin, orbifloxacin, oxolinic acid and sarafloxacin) in muscle, liver, chicken eggs, milk, prawn and rainbow trout.The quinolones were extracted from a sample with acetonitrile-water (95 : 5). A fifth part of the filtered extract was diluted with water to keep the acetonitrile ratio at ca. 60%, and passed through a C18 mini-column. The eluate was evaporated to dryness, and the residues were dissolved in methanol-water (30 : 70) for HPLC analysis.The quinolones were separated on a Inertsil ODS-3V column (4.6 mm i.d.x250 mm) with a gradient system of 0.1% phosphoric acid-acetonitrile as the mobile phase, with fluorescence detection.No interfering peak was found on the chromatograms of animal and fishery products, except for milk. The recoveries of the quinolones were over 60% from the animal and fishery products fortified at 0.1 microg/g, and the quantification limits of the quinolones were 0.005 microg/g. This proposed method was found to be effective and suitable for the screening of the quinolones in animal and fishery products. 相似文献
GeTe is a promising candidate for the fabrication of high-temperature segments for p-type thermoelectric (TE) legs. The main restriction for the widespread use of this material in TE devices is high carrier concentration (up to ∼ 1021 cm−3), which causes the low Seebeck coefficient and high electronic component of thermal conductivity. In this work, the band structure diagram and phase equilibria data have been effectively used to attune the carrier concentration and to obtain the high TE performance. The Ge1−xBixTe (x = 0.04) material prepared by the Spark plasma sintering (SPS) technique demonstrates a high power factor accompanied by moderate thermal conductivity. As a result, a significantly higher dimensionless TE figure of merit ZT = 2.0 has been obtained at ∼ 800 K. Moreover, we are the first to propose that application of the developed Ge1−xBixTe (x = 0.04) material in the TE unicouple should be accompanied by SnTe and CoGe2 transition layers. Only such a unique solution for the TE unicouple makes it possible to prevent the negative effects of high contact resistance and chemical diffusion between the segments at high temperatures. 相似文献
Calculation of the underground temperature resulting from heat injection/extraction into/from ground heat exchangers (GHEXs) with hourly variation is one of the most noteworthy challenges to address when simulating and designing a ground source heat pump (GSHP). In order to overcome this challenge, the authors introduce a method to calculate the underground temperature, by considering heat injection/extraction into/from GHEXs with hourly variation. The method applies the superposition of the infinite cylindrical source (ICS) solution and the infinite line source (ILS) solution to calculate the temperature change due to heat injection/extraction into/from the considered GHEX and other neighboring GHEXs, respectively. The calculation method also considers heat injection/extraction from GHEXs with different heat injection/extraction rates and is able to accommodate GHEXs with large diameters such as energy piles. The calculation method was evaluated by applying it to calculate the temperature variation of the heat carrier fluid in a GSHP system with energy piles. 相似文献
ABSTRACTThe thermal-neutron capture cross-section (σ0) and resonance integral (I0) were measured for the 135Cs(n,γ)136Cs reaction by an activation method and mass spectrometry. Because of difficulty in the preparation of pure 135Cs samples, we used 135Cs contained as an impurity in a normally available 137Cs standard solution. An isotope ratio of 135Cs and 137Cs in a standard 137Cs solution was measured by mass spectrometry to quantify 135Cs. Cesium-135 impurity along with the 137Cs standard solution was irradiated at the hydraulic conveyer of the research reactor in the Institute for Integral Radiation and Nuclear Science, Kyoto University. Wires of Co/Al and Au/Al alloys were used as neutron monitors to measure thermal-neutron fluxes and epi-thermal Westcott’s indices at an irradiation position. A gadolinium filter was used to measure the σ0, and a value of 0.133 eV was taken as the cut-off energy. Gamma-ray spectroscopy was used to measure induced activities of 137Cs, 136Cs and monitor wires. On the basis of Westcott’s convention, the σ0 and I0 values were derived as 8.57 ± 0.25 barn, and 45.3 ± 3.2 barn, respectively. The value of σ0 obtained in the present study agreed within the limits of uncertainties with the past-reported value of 8.3 ± 0.3 barn. 相似文献