It has long been known that in some relatively simple reinforcement learning tasks traditional strength-based classifier systems will adapt poorly and show poor generalisation. In contrast, the more recent accuracy-based XCS, appears both to adapt and generalise well. In this work, we attribute the difference to what we call strong over general and fit over general rules. We begin by developing a taxonomy of rule types and considering the conditions under which they may occur. In order to do so an extreme simplification of the classifier system is made, which forces us toward qualitative rather than quantitative analysis. We begin with the basics, considering definitions for correct and incorrect actions, and then correct, incorrect, and overgeneral rules for both strength and accuracy-based fitness. The concept of strong overgeneral rules, which we claim are the Achilles' heel of strength-based classifier systems, are then analysed. It is shown that strong overgenerals depend on what we call biases in the reward function (or, in sequential tasks, the value function). We distinguish between strong and fit overgeneral rules, and show that although strong overgenerals are fit in a strength-based system called SB-XCS, they are not in XCS. Next we show how to design fit overgeneral rules for XCS (but not SB-XCS), by introducing biases in the variance of the reward function, and thus that each system has its own weakness. Finally, we give some consideration to the prevalence of reward and variance function bias, and note that non-trivial sequential tasks have highly biased value functions. 相似文献
Herein we report on the synthesis of a metastable (Cr,Y)2AlC MAX phase solid solution by co-sputtering from a composite Cr–Al–C and elemental Y target, at room temperature, followed by annealing. However, direct high-temperature synthesis resulted in multiphase films, as evidenced by X-ray diffraction analyses, room-temperature depositions, followed by annealing to 760°C led to the formation of phase pure (Cr,Y)2AlC by diffusion. Higher annealing temperatures caused a decomposition of the metastable phase into Cr2AlC, Y5Al3, and Cr-carbides. In contrast to pure Cr2AlC, the Y-containing phase crystallizes directly in the MAX phase structure instead of first forming a disordered solid solution. Furthermore, the crystallization temperature was shown to be Y-content dependent and was increased by ∼200°C for 5 at.% Y compared to Cr2AlC. Calculations predicting the metastable phase formation of (Cr,Y)2AlC and its decomposition are in excellent agreement with the experimental findings. 相似文献
Effects of radiographic contrast media (RCM) application were demonstrated in vitro and in vivo where the injection of RCM into the A. axillaris of patients with coronary artery disease was followed by a significant and RCM-dependent decrease of erythrocyte velocity in downstream skin capillaries. Another study in pigs revealed that the deceleration of erythrocytes coincided with a significant reduction of the oxygen partial pressure in the myocardium—supplied by the left coronary artery—after the administration of RCM into this artery. Further reports showed RCM dependent alterations of erythrocytes like echinocyte formation and exocytosis, sequestration of actin or band 3 and the buckling of endothelial cells coinciding with a formation of interendothelial fenestrations leading to areas devoid of endothelial cells. Key to morphological alterations of erythrocytes is the membrane cytoskeleton, which is linked to the band 3 in the erythrocyte membrane via the junctional complex. Fundamental observations regarding the cell biological and biochemical aspects of the structure and function of the cell membrane and the membrane cytoskeleton of erythrocytes have been reported. This review focuses on recent results gained, e.g., by advanced confocal laser scanning microscopy of different double-stained structural elements of the erythrocyte membrane cytoskeleton. 相似文献
A new pseudoreceptor modeling method (PRPS) was applied to the refinement of a homology model of the human histamine H4 receptor (H4R), the prediction of a ligand binding site, and virtual screening. Retrieval of two new H4R ligands demonstrates the biological relevance of the pseudoreceptor model and provides a means for finding new hits and leads in the early phases of drug discovery.
Beef blocks of two compositions, 100% and 50% visual lean (VL), in standard commercial packaging with nominal dimensions of 510 × 390 × 150 mm were tempered from −18 °C to −3 °C using air at temperatures from 3 °C to −3 °C and velocities of 0.5 and 5 ms−1. These conditions were then modelled using a finite difference mathematical model and the accuracy of the model assessed by comparison with the experimental results. An extended range of conditions (including an intermediate air velocity of 2 ms−1 and an intermediate composition of 75% VL) was then modelled to produce data that can be used to design tempering processes.
The results show that single stage air tempering of even single blocks within their cartons needs to be a long process. In air at 3 °C and 5 ms−1, blocks of 50% VL rose to deep temperatures of −10 °C and −3 °C after 4.0 and 22.5 h, respectively, while with 100% VL 4.6 and 27.3 h were required. Under these conditions, the surface layers of the meat would have spent many hours in a thawed condition that would be detrimental to both drip and optimal processing. Using lower temperatures avoids thawing and at the same time produces an optimum temperature difference for subsequent processing. However, tempering times are substantially extended. For example, times to the above temperatures using air at −1 °C and 5 ms−1 were 4.8 and 37.5 h for 50% VL and 5.1 and 44.5 h for 100% VL. 相似文献
Compared with traditional boning of split refrigerated carcasses, hot boning of intact carcasses (the removal of meat from the skeleton prerigor) provides several commercially important cuts, may improve quality and reduce refrigeration costs, and may reduce the contamination of carcasses with central nervous system (CNS) tissue. In a comparative study of hot boning of intact and split carcasses, the CNS tissue contamination of intact carcasses was negligible (as measured with the CNS-related proteins glial fibrillary acidic protein and S-100 protein), but split carcasses were highly contaminated. The same trends were observed for dissection worktables used during the boning process. Most current boning plants have processing lines that are organized for boning carcass quarters, where the carcasses, in addition to transversal division, also are split horizontally. This part of the boning process was incorporated in the design of our study. Nine of the 18 intact carcasses were split horizontally between thoracic vertebrae 10 and 11 before they were hot boned. CNS tissue contamination was not detected on the carcass site related to this procedure. The amount of CNS tissue contamination was similar in boned cuts and minced meat from split and intact carcasses, except in the forerib. Boning of split carcasses appears to reduce CNS tissue contamination significantly to a level comparable to that of intact hot-boned carcasses. 相似文献
Practitioners are continuing to develop egress modelling software for the design of the built environment. These models require data about human behaviour and factors for calibration, validation and verification. This study aims to address the specific data and knowledge gap: emergency egress of the elderly. Such data are difficult to collect given privacy and consent concerns, with strong relationships generally being required between residences and researchers. Through the observation of nine fire drills at six Canadian long-term care (LTC) and retirement homes, specific evacuation actions and behaviour were observed for 37 staff members and information about the evacuation of 56 residents was collected. These drills demonstrated that emergency egress in LTC and retirement homes is highly staff dependent with 72% of residents recorded requiring full assistance at all stages of movement in evacuation, and that the type of announced/unannounced drill and level of resident care will affect the type of data collected. The development of travel speed and pre-movement is discussed subject to limitation with qualitative behavioural insights of residents that were observed. This study provides valuable methodological discussion on how to conduct behavioural studies in similar highly restricted research environments. Specific attention is given to understanding the considerations that must be made when using fire drills as data sources, and the impact that these can have on using such data for modelling. This study may inform the initial setup and programming of evacuation models from an actions and behavioural perspectives of staff members and residents. 相似文献
Many systems used in buildings for heating, ventilating, and air-conditioning waste energy because of the way they are operated or controlled. This paper explores the application of model predictive control (MPC) to air-conditioning units and demonstrates that the closed-loop performance and energy efficiency can be improved over conventional approaches. This work focuses on the problem of controlling the vapor compression cycle (VCC) in an air-conditioning system, containing refrigerant which is used to provide cooling. The VCC considered in this work has two manipulated variables that affect operation: compressor speed and the position of an electronic expansion valve. The system is subject to constraints, such as the range of permissible superheat, and also needs to regulate temperature variables to set points. An MPC strategy is developed for this type of system based on linear models identified from data obtained from a first-principles model of the VCC. The MPC strategy incorporates economic measures in the objective function as well as control objectives. Tests are carried out on a simulated VCC system that is linked to a simulation of a realistic building that is developed in the U.S. Department of Energy Computer Simulation Program, EnergyPlus. The MPC demonstrated significantly better tracking control relative to conventional approaches (a reduction of 70% in terms of the integral of squared error for step changes in the temperature set-point), while reducing the VCC energy requirements by 16%. The paper describes the control approach in detail and presents results from the tests. 相似文献