给出了采用IGBT的±20kVarDSTATCOM的实现方法及实验结果.单相逆变器采用特定谐波消除PWM算法(SHE-PWM)以保证输出无功电流的谐波总畸变率小于5%,三相补偿电流相量采用对称分量法通过矢量变换获得.试验结果验证了DSTATCOM进行平衡化补偿的快速性. 相似文献
64.
应用于 DSTATCOM 的负序电流优先补偿策略 总被引:1,自引:0,他引:1
为了提高配电网静止同步补偿器(distribution-level static reactive compensator,DSTATCOM)补偿负荷的灵活性,提出了一种针对 DSTATCOM 的电流优化补偿策略,即负序电流优先补偿策略.当 DSTATCOM 的容量能够补偿全部的负序电流分量却不能补偿全部负荷电流时,该补偿策略能够完全补偿负序分量、保证无功分量的最大程度补偿.在配电网的电能质量治理中,该补偿策略优先保证了系统的三相电压对称性.该策略能够应用于星形或角型拓扑的DSTATCOM 中,仿真结果证明了其有效性和准确性. 相似文献
65.
This paper presents a distribution static compensator (DSTATCOM) for power quality improvements in terms of harmonics and power factor correction in a three-phase four-wire distribution system. The DSTATCOM is implemented with PWM current controlled six-leg voltage source converter (VSC) and the switching patterns are generated through a novel synchronous reference frame controller (SRFC). The insulated gate bipolar transistor (IGBT) based VSC is supported by a capacitor and is controlled for the required compensation of the load current. The DSTATCOM is connected to the power system feeding nonlinear loads. Nonlinear loads include either current-source type or voltage-source type. Harmonic spectrum of the source current is compared in between without DSTATCOM and with DSTATCOM by considering both types of nonlinear loads. The SRFC based DSTATCOM system is validated through extensive simulation for diode-rectifier and unbalanced R–L loads with a case study. 相似文献
66.
针对新景矿选煤厂配电系统电压存在的电压跌落、无功功率低的问题,首先完成电压跌落成因分析、电压跌落抑制方法分析,并在此基础上对电压跌落补偿方案进行容量、外形设计与改造。对改造后的配电系统进行工业试验,结果表明,经补偿方案处理后,选煤厂配电系统的电压、电流波形明显改善,谐波电压总畸变率下降至1.00%,有益于选煤厂配电系统安全、稳定、高效运行。 相似文献
67.
分析了影响配电用静止无功补偿器(DSTATCOM)工作稳定性的若干干扰因素。提出了硬件和软件2方面的抗干扰措施。硬件措施包含匹配缓冲电路参数、合理处理地线、对重要信号进行隔离等。软件措施包括数字滤波、设置看门狗定时时钟及程序陷阱等。给出了样机采用抗干扰技术前后的大量实验波形,并分析了各种抗干扰技术的作用和效果。实验证明,所采用的抗干扰技术增强了DSTATCOM的抗干扰能力,提高了其工作稳定性。 相似文献
68.
An Luo Lu FangShuangjian Peng Chuanping WuHouhui Fang 《International Journal of Electrical Power & Energy Systems》2011,33(2):322-331
This paper analyses the negative sequence equivalent circuit of DSTATCOM in unbalanced distribution networks. A new control model of negative sequence voltage without current sensors based on instantaneous power balancing algorithm is deduced. To compensate for balanced and unbalanced voltages, a new cascade voltage loop control strategy, in which the negative sequence voltage control loop is parallel to the positive sequence voltage loop, is proposed. Then the mathematical model of the new cascade loop voltage control method is discussed. The DSTATCOM output voltage command is directly obtained from the bus voltage at the Point of Common Coupling (PCC) and the DC-side voltage via a simple algebraic algorithm based on power balance equation. In addition, the implementation costs can be reduced since current sensors are not required in the proposed control strategy. Simulation and industrial application results are presented to verify the validity of the proposed control strategy. It is successfully implemented in the DSTATCOM installed in the Lianyuan Iron and Steel Corporation in Hunan province of China. 相似文献
69.
针对传统配电网静止同步补偿器补偿容量小、冲击电流大等问题,本文提出基于模块化多电平逆变器的三相四线制配电网静止同步补偿器(D-STATCOM)。首先分析了MMC-DSTATCOM的拓扑结构和等效模型,叠加有功电流平衡直流侧电压和根据充放电关系保证子模块电压,同时考虑环流抑制,叠加二倍频电压消除环流影响,得出了利用载波移相技术实现等效输出端电压输出,从而实现对配电网的综合补偿效果,最后利用Matlab/Simuilink环境中搭建模型进行仿真分析,证实所提方法的有效性和可行性。 相似文献
70.
直流侧电容电压的稳定是配电网静止同步补偿器(DSTATCOM)能够正常工作的前提条件。针对传统控制方法在直流侧电压建立过程中存在较大超调量和启动电流涌流的问题,从浮动调节直流侧电压参考值角度出发,设计一种简易模糊PI控制器,实现了DSTATCOM的阶梯渐变式无超调升压。该新型方法既解决了传统常规PI控制器对模型精确性要求较高、易引起超调和抗干扰能力差的问题,又有效地减少了一般模糊控制带来的时间延迟。对所提出的简易模糊PI控制策略进行MATLAB仿真,并制作一台容量为10k VA的DSTATCOM实验样机,通过仿真和实验验证了该新型直流侧电压控制策略的有效性和可行性。 相似文献