The article investigates the finite sample properties of estimators for spatial autoregressive models where the disturbance
terms may follow a spatial autoregressive process. In particular we investigate the finite sample behavior of the feasible
generalized spatial two-stage least squares (FGS2SLS) estimator introduced by Kelejian and Prucha (1998), the maximum likelihood
(ML) estimator, as well as that of several other estimators. We find that the FGS2SLS estimator is virtually as efficient
as the ML estimator. This is important because the ML estimator is computationally burdensome, and may even be forbidding
in large samples, while the FGS2SLS estimator remains computationally feasible in large samples.
Received: 20 January 2001 / Accepted: 31 August 2001 相似文献
The Co/MFI(SiO2/Al2O3 = 30) were prepared by a precipitation method with NaOCl in alkali solutions exhibited high activities to N2 at 250 °C for the selective catalytic reduction (SCR) of NOx. These catalysts showed two UV–vis bands at 700 and 400 nm, indicating the presence of octahedral Co(III) as well as tetrahedral Co(II). The high SCR activity over such Co(III, II)/MFI(30) seems to come from Co(III)---O moieties. The Co(II)MFI(30) catalysts prepared from Co(II)Cl2 exhibited low SCR activities due to the presence of tetrahedral Co(II) ions in MFI. Less CO formation occurred over Co/MFI catalysts. The Fe/MFI(30) catalyst exhibited high activity due to the presence of some Fe---O species in MFI but more amount of CO were produced during SCR. H/MFI(30) catalyst exhibited a good SCR activity. However, more amount of carbonaceous deposits were produced on it. The correlation between acid concentration and SCR activity was discussed over H/MFIs. 相似文献
1. 1. System design optimization and validation for single-speed heat pump by S.K. Fischer and C.K. Rice, Oak Ridge National Laboratories.
2. 2. Analysis of on/off cycling for an air-to-air heat pump operating in the heating mode by W.A. Miller, Oak Ridge National Laboratories.
3. 3. Field measured cycling, frosting and defrosting losses for a high efficiency air source heat pump by V.D. Baxter and J.C. Moyers, Oak Ridge National Laboratories.
4. 4. Design and available energy analysis of a heating-only residential heat pump for the Western Pacific Northwest by D.E. Elger, C.M. Reistad and S. Lang, Oregon State University.
5. 5. A study of heat pump service life by Nance C. Lovvorn, Alabama Power Company and Carl C. Hiller, Electric Power Research.
Résumé
1. 1. Optimisation de la conception des systèmes et application à la pompe à chaleur à une seule vitesse;
2. 2. analyse du cycle par tout ou rien d'une pompe à chaleur air-air fonctionnant en mode de chauffage;
3. 3. pertes en fonctionnement cyclique, par givrage et dégivrage mesurées sur place pour une pompe à chaleur de grand rendement dont la source est l'air;
4. 4. conception et analyse de l'énergie disponible d'une pompe à chaleur uniquement pour le chauffage de locaux résidentiels sur la côte du Pacifique nord-ouest occidental;
5. 5. étude de la durée de vie d'une pompe à chaleur.
Les noms et les addresses des auteurs se trouvent dans le sommaire anglais. 相似文献
This paper describes the creep‐fatigue life of Sn–8Zn–3Bi under push–pull loading. Creep‐fatigue tests were carried out using Sn–8Zn–3Bi specimens in fast–fast, fast–slow, slow–fast, slow–slow and hold–time strain waveforms. Creep‐fatigue lives in the slow–slow and hold‐time waveforms showed a small reduction from the fast–fast lives but those in the slow–fast and fast–slow waveforms showed a significant reduction from the fast–fast lives. Conventional creep‐fatigue life prediction methods were applied to the experimental data and the applicability of the methods was discussed. Creep‐fatigue characteristics of Sn–8Zn–3Bi were compared with those of Sn–3.5Ag and Sn–37Pb. 相似文献
This paper generalizes the frequency-domain results on the delay-type Nehari problem in the stable case to the unstable case. The solvability condition of the delay-type Nehari problem is formulated in terms of the nonsingularity of three matrices. The optimal value γopt is the maximal γ∈(0,∞) such that one of the three matrices becomes singular. All sub-optimal compensators are parameterized in a transparent structure incorporating a modified Smith predictor. 相似文献
This paper looks into a new area for knowledge-based system application, that of manufacturing modelling. Manual generation of IDEF0 models of manufacturing systems is time-consuming and inconsistent. However, the process can be automated to improve timeliness and consistency. In this paper, a knowledge-based manufacturing modelling system for the automatic generation of IDEF0 models is proposed. The system will not only greatly reduce the IDEF0 modelling time but will also eliminate the inconsistency problem of conventional IDEF0 modelling systems. The paper explains the knowledge-based approach and identifies the kinds of domain knowledge that are required for the construction of the knowledge-based manufacturing modelling system. 相似文献
An equation of state for 1,1-difluoroethane (HFC 152a, CH3CHF2) has been developed on the basis of reliable experimental data including PVT, liquid Cp, and saturated-liquid-density data measured by our group. It is a non-dimensionalized virial equation whose functional form is the same as that originally developed for 1,1,1,2-tetrafluoroethane (HFC 134a) in our group. The effective range is for pressures up to 15 MPa, temperatures from 230 to 450 K, and densities to 1000 kg m−3. The equation represents reliable PVT measurements within ± 1% in pressure for the superheated vapour and supercritical fluid, while within ±0.5% in density for the compressed liquid. In addition, it should be noted that the equation represents the other essential thermodynamic properties including vapour pressures, saturated-liquid/ vapour densities, isobaric/isochoric specific heats and sound velocity in both the liquid and gaseous phase of HFC 152a. 相似文献
In principle, absorption chillers of the ammonia-water type could work at temperatures well below the usual air-conditioning temperatures, arriving at the range 250–260 K, which can be useful for refrigeration applications. This possibility is studied for an air-cooled machine, comparing the results with the experimental data supplied by a manufacturer that recently commercialized such a refrigerator. The prediction is fair, and the study allows an insight into the internal parameters and into the possible behaviour for more severe conditions than those studied. 相似文献
Organic electroluminescent thin film using Znq2(Znq2) as the emitting layer material with structure of glass/ITO/Znq2/Al(cell) was fabricated.The V-I curve ,V-B curve and electroluminescent spectra of the cell were measured.Meanwhile the fluorescent spectra, excited spectra and absorption spectra of Znq2 with power and film states were also measured. 相似文献