1. 1. System design optimization and validation for single-speed heat pump by S.K. Fischer and C.K. Rice, Oak Ridge National Laboratories.
2. 2. Analysis of on/off cycling for an air-to-air heat pump operating in the heating mode by W.A. Miller, Oak Ridge National Laboratories.
3. 3. Field measured cycling, frosting and defrosting losses for a high efficiency air source heat pump by V.D. Baxter and J.C. Moyers, Oak Ridge National Laboratories.
4. 4. Design and available energy analysis of a heating-only residential heat pump for the Western Pacific Northwest by D.E. Elger, C.M. Reistad and S. Lang, Oregon State University.
5. 5. A study of heat pump service life by Nance C. Lovvorn, Alabama Power Company and Carl C. Hiller, Electric Power Research.
Résumé
1. 1. Optimisation de la conception des systèmes et application à la pompe à chaleur à une seule vitesse;
2. 2. analyse du cycle par tout ou rien d'une pompe à chaleur air-air fonctionnant en mode de chauffage;
3. 3. pertes en fonctionnement cyclique, par givrage et dégivrage mesurées sur place pour une pompe à chaleur de grand rendement dont la source est l'air;
4. 4. conception et analyse de l'énergie disponible d'une pompe à chaleur uniquement pour le chauffage de locaux résidentiels sur la côte du Pacifique nord-ouest occidental;
5. 5. étude de la durée de vie d'une pompe à chaleur.
Les noms et les addresses des auteurs se trouvent dans le sommaire anglais. 相似文献
Since electronic switching systems usually require very strict reliability requirements as well as good performance objectives, we need to jointly analyse the performance and reliability of switching systems. In this paper, we compare conventional time–space–time switches with single space switches with those with multiple separated space switches, from the viewpoints of reliability and performance. We consider time–space–time switching networks which consist of N incoming time switches, i.e. one NxN space switch, two (N/2)x(N/2) space switches, and four (N/4)x(N/4) space switches. We introduce a Markov reliability model to study the effect of failures and analyse the reliability and performance of three different types of switching networks in terms of average blocking probability and the mean time to unreliable operation, as we vary the offered traffic. As a result, T–S–T switching networks with multiple separated space switches exhibit better performance and reliability than those with single space switches. 相似文献
The bond strength and slip of epoxy-coated reinforcing bars in concrete have been evaluated by carrying out single pullout and double pullout tests. In extended single pullout tests, slip measurements were made while tensile force was applied to reinforcing bars embedded in concrete. In double pullout tests, 20 cycles of load were applied at levels of steel stress between zero and 0·5 times characteristic steel strength. Strains were measured by electrical resistance strain gauges glued inside the bars. Both epoxy-coated and uncoated bars were used in the investigation, to obtain comparative results. The strain gradient along the bar was found to be less for the coated reinforcement. In general, the epoxy coating was found to increase slip in bond and thereby reduce the bond performance of coated bars. 相似文献
Sucrose crystallization in thin films (50–55 μm) was studied, using a videomicroscopy technique, at conditions encountered during hard panning processes. No nucleation occurred in unseeded films, while a linear increase in seeded crystals occurred during drying. Crystal growth rate increased with temperature (25–30°C) and with air velocity (2.4–12.5 m/sec), but did not change with varying sucrose concentrations (70–76% w/w) and relative humidities (0–66% at 30°C). FD & C Yellow No. 5 food coloring in the dye form (0.05–0.5 g/100 mL) showed no effects while similar concentrations in the lake form inhibited crystal growth rate. 相似文献