The difference in the turbulent diffusion between the active (heat) and passive (mass) scalars in a thermally stably stratified medium is investigated. The axisymmetric problem is treated on the formation of a turbulent circulation flow above a heated disk and on the turbulent diffusion of a passive scalar (impurity) from a continuous surface source in a stably stratified medium. The results indicate that the thermal stratification causes appreciable differences in the coefficients of turbulent transfer between the active (heat) and passive (mass) scalars. This means that the assumption of the identity of the coefficient of turbulent diffusion of heat and mass, employed in conventional models of turbulence, produces significant errors in estimating the heat and mass transfer in a thermally stably stratified medium. 相似文献
1. 1. System design optimization and validation for single-speed heat pump by S.K. Fischer and C.K. Rice, Oak Ridge National Laboratories.
2. 2. Analysis of on/off cycling for an air-to-air heat pump operating in the heating mode by W.A. Miller, Oak Ridge National Laboratories.
3. 3. Field measured cycling, frosting and defrosting losses for a high efficiency air source heat pump by V.D. Baxter and J.C. Moyers, Oak Ridge National Laboratories.
4. 4. Design and available energy analysis of a heating-only residential heat pump for the Western Pacific Northwest by D.E. Elger, C.M. Reistad and S. Lang, Oregon State University.
5. 5. A study of heat pump service life by Nance C. Lovvorn, Alabama Power Company and Carl C. Hiller, Electric Power Research.
Résumé
1. 1. Optimisation de la conception des systèmes et application à la pompe à chaleur à une seule vitesse;
2. 2. analyse du cycle par tout ou rien d'une pompe à chaleur air-air fonctionnant en mode de chauffage;
3. 3. pertes en fonctionnement cyclique, par givrage et dégivrage mesurées sur place pour une pompe à chaleur de grand rendement dont la source est l'air;
4. 4. conception et analyse de l'énergie disponible d'une pompe à chaleur uniquement pour le chauffage de locaux résidentiels sur la côte du Pacifique nord-ouest occidental;
5. 5. étude de la durée de vie d'une pompe à chaleur.
Les noms et les addresses des auteurs se trouvent dans le sommaire anglais. 相似文献
The off‐axis fatigue cracking behaviour of notched fibre metal laminates under constant amplitude loading conditions was investigated experimentally and numerically. It was found that the off‐axis fatigue crack initiation life decreased as the off‐axis angles increased. This indicated that the off‐axis laminates raised the applied stress level in the aluminium (Al) layer and subsequently resulted in earlier cracking in the Al layer. The off‐axis fatigue crack initiation lives of notched fibre metal laminates were predicted using lamination theory and an energy‐based critical plane fatigue damage analysis from the literature. After a crack initiated in the Al layer, it was observed that the crack path angles of the off‐axis specimens were neither perpendicular to the fibre nor to the loading direction. A finite‐element model was established for predicting the crack path angles. 相似文献
GLARE is a fibre metal laminate (FML) built up of alternating layers of S2-glass/FM94 prepreg and aluminium 2024-T3. The excellent fatigue behaviour of GLARE can be described with a recently published analytical prediction model. This model is based on linear elastic fracture mechanics and the assumption that a similar stress state in the aluminium layers of GLARE and monolithic aluminium result in the same crack growth behaviour. It therefore describes the crack growth with an effective stress intensity factor (SIF) range at the crack tip in the aluminium layers, including the effect of internal residual stress as result of curing and the stiffness differences between the individual layers. In that model, an empirical relation is used to calculate the effective SIF range, which had been determined without sufficiently investigating the effect of crack closure. This paper presents the research performed on crack closure in GLARE. It is assumed that crack closure in FMLs is determined by the actual stress cycles in the metal layers and that it can be described with the available relations for monolithic aluminium published in the literature. Fatigue crack growth experiments have been performed on GLARE specimens in which crack growth rates and crack opening stresses have been recorded. The prediction model incorporating the crack closure relation for aluminium 2024-T3 obtained from the literature has been validated with the test results. It is concluded that crack growth in GLARE can be correlated with the effective SIF range at the crack tip in the aluminium layers, if it is determined with the crack closure relation for aluminium 2024-T3 based on actual stresses in the aluminium layers. 相似文献
TiN coatings were deposited on polished substrates of W18Cr4V high speed steel by means of vacuum arc ion plating. The effect of cerium on adhesion between TiN coating and substrate was studied. The microstructures and composition of TiN coatings were also investigated by means of scanning electron microscope (SEM), Auger electron spectroscopy (AES), and X-ray diffraction (XRD) technique. It was found that cerium is an effective modifying agent and the addition of suitable amount of cerium to TiN coatings can produce relatively excellent properties such as micro-hardness, wear resistance, oxidation resistance and porosity. The experimental results show that the added cerium in TiN coatings makesa contribution to form the preferred direction along with a (111 ) or (222) close packed face, which may be one of the reasons that improves some properties mentioned above. 相似文献