11.
A lumped-parameter dynamic simulation of a single-effect ammonia–water absorption chiller is performed. Modeling is based on the continuity of species constituting the ammonia–water mixture and the conservation of energy for each component of the absorption chiller. Ordinary differential equations governing the response of each component and the algebraic equations describing the constitutive relation are solved in parallel by numerical integration. The model has been applied to a commercially available 10.5 kW absorption chiller to study the transients of temperature, pressure, concentration, and void fraction of each component during the start-up operation. The time constant of the absorption chiller is also investigated. The parameters considered are the bulk concentration of the ammonia–water solution, the mass of the solution filled, and the volumes of key components of the absorption chiller. In addition, the reduction of the time constant by a stepwise turn-up and turn-down of the flue gas flow rate during the primary stage of start-up period is demonstrated.  相似文献   
12.
In ammonia–water absorption refrigeration systems a purification process of the vapours produced in the generator is required. One type of equipment to carry out the purification process is a packed column. However, detailed experimental studies at the normal operating conditions found in ammonia–water absorption refrigeration systems have not been found. An experimental facility has been designed and built to study the ammonia–water rectification in packed columns. Experimental tests have been performed at the normal operating conditions found in the high-pressure stage of a small power ammonia–water absorption refrigeration system. In this paper, the experimental set-up is described and experimental results of the height equivalent to a theoretical plate (HETP) and the volumetric mass transfer coefficient of a rectifying section with the Sulzer BX packing are presented. The HETP values and the experimental mass transfer coefficients are compared with different data and correlations proposed in the literature; it has been found that the differences are appreciable.  相似文献   
13.
Falling-film heat and mass transfer in an absorber can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat and mass transfer has been investigated for a falling-film helical coil absorber which is frequently used in the ammonia/water absorption refrigerators. The heat and mass transfer performance was measured for both parallel and countercurrent flow. The experiments were carried out for three different solution concentrations (3, 14, and 30%). The vapor in equilibrium with the solution is supplied to the test section. It is found that the falling-film heat and mass transfer is deteriorated in the countercurrent flow if the specific volume of the vapor solution is large. For the countercurrent flow, the high velocity of the vapor due to large specific volume seems to cause the unfavorable distribution of falling-film and reduce the heat and mass transfer performance of the ammonia absorber. The effect of vapor flow direction decreased with increasing concentration of ammonia solution since the specific volume of the ammonia vapor which is in equilibrium with the solution becomes smaller and the vapor velocity becomes lower.  相似文献   
14.
The objectives of this paper are to examine the effect of nano particles on the bubble type absorption by experiment and to find the optimal conditions to design highly effective compact absorber for NH3/H2O absorption system. The initial concentrations of NH3/H2O solution and the kinds and the concentrations of nano particles are considered as key parameters. The results show that the addition of nano particles enhances the absorption performance up to 3.21 times. Moreover, the absorption rate increases with increasing concentration of nano particles and the nano particles are more effective for lower absorption potential solution. The potential enhancement mechanism for binary nanofluid is suggested. The experimental correlations of the effective absorption ratio for each nano particles, Cu, CuO, and Al2O3, are suggested within ±10% error-band.  相似文献   
15.
In this paper, the thermoeconomic concept is applied to the optimization of an aqua-ammonia vapour-absorption refrigeration (VAR) system—aimed at minimizing its overall product cost. The thermoeconomic concept based simplified cost minimization methodology calculates the economic costs of all the internal flows and products of the system by formulating thermoeconomic cost balances. The system is then thermoeconomically evaluated to identify the effects of design variables on costs and thereby enables to suggest values of design variables that would make the overall system cost-effective. Based on these suggestions, the optimization of the system is carried out through an iterative procedure. The results show a significant improvement in the system performance without any additional investment. Finally, sensitivity analysis is carried out to study the effect of the changes in fuel cost to the system parameters.  相似文献   
16.
Ammonia–water hybrid absorption–compression heat pumps (HACHP) are a promising technology for development of efficient high temperature industrial heat pumps. Using 28 bar components HACHPs up to 100 °C are commercially available. Components developed for 50 bar and 140 bar show that these pressure limits may be possible to exceed if needed for actual applications. Feasible heat supply temperatures using these component limits are investigated. A feasible solution is defined as one that satisfies constraints on the COP, low and high pressure, compressor discharge temperature, vapour water content and volumetric heat capacity. The ammonia mass fraction and the liquid circulation ratio both influence these constraining parameters. The paper investigates feasible combinations of these parameters through the use of a numerical model. 28 bar components allow temperatures up to 111 °C, 50 bar up to 129 °C, and 140 bar up to 147 °C. If the compressor discharge temperature limit is increased to 250 °C and the vapour water content constraint is removed, this becomes: 182 °C, 193 °C and 223 °C.  相似文献   
17.
In this paper, the mass transfer performance of a large-specific-area corrugated sheet structured packing for ammonia–water absorption refrigeration systems (AARS) is reported. An experimental facility was used to test the performance of the packing. Experimental results of the temperature, ammonia concentration and mass flow rate of the rectified vapour are presented and discussed for different operating conditions including reflux ratio values from 0.2 to 1. The volumetric vapour phase mass transfer coefficient is calculated from the measured data and compared with different correlations found in the literature. A new correlation is proposed which was fitted from the experimental data. Finally, a comparison is made between the actual packing height used in the experimental setup and the height required to obtain the same ammonia rectification in AARS with different packings previously tested by the authors.  相似文献   
18.
In this paper, the mass transfer performance of the 10 mm metal Pall ring packing for ammonia rectification in ammonia–water absorption refrigeration systems (AARS) is investigated. The experimental setup is described and the experimental procedure and data reduction method are explained. Experimental results of the top vapour temperature, concentration and mass flow rate are presented for different operating conditions, including reflux ratio values from 0.4 to 1 (total reflux conditions). Vapour phase mass transfer coefficients are calculated from the measured data and the results are compared with different mass transfer correlations found in the open literature. In this paper, a correlation is proposed for the packing analysed which was fitted from the experimental data. Finally, a comparison is made between the actual packing height used in the experimental setup and the height required to obtain the same ammonia rectification in AARS with the first generation packings: ½″ ceramic Berl saddles, 15 mm glass Raschig rings and ½″ ceramic Novalox saddles. It was found that a packing height reduction between a factor of 2.5 and 3 is attained with 10 mm metal Pall rings.  相似文献   
19.
An improved system of NH3–H2O–LiBr was proposed for overcoming the drawback of NH3–H2O absorption refrigeration system. The LiBr was added to NH3–H2O system anticipating a decrease in the content of water in the NH3–H2O–LiBr system. An equilibrium cell was used to measure thermal property of the ternary NH3–H2O–LiBr mixtures. The pressure–temperature data for their vapor–liquid equilibrium (VLE) data were measured at ten temperature points between 15–85 °C, and pressures up to 2 MPa. The LiBr concentration of the solution was chosen in the range of 5–60% of mass ratio of LiBr in pure water. The VLE for the NH3–H2O–LiBr ternary solution was measured statically. The experimental results show that the equilibrium pressures reduced by 30–50%, and the amount of component of water in the gas phase reduced greatly to 2.5% at T=70 °C. The experimental results predicted much better characteristics of the new ternary system than the NH3–H2O system for the applications.  相似文献   