The fire behaviour involving multiple fires in a mine drift with longitudinal ventilation was analysed. The conditions and fire phenomena occurring were described. The analysis was based upon experimental data from model-scale fire experiments. A fire involving several fuel items may lead to flames tilted horizontally and filling up the entire cross section, leading to earlier ignition, higher fire growth rates, higher fire spread rate and severe fire behaviour. Longer flame lengths will also result due to decreased air entrainment. A correlation for the continuous flame length was proposed. The results of the analysis will help identifying and preventing potentially dangerous fire situations with several large combustible items distributed along a mine drift. 相似文献
Service differentiation and the use of "appropriate technologies" are often presented as alternative approaches to providing water service to low-income areas. Service differentiation allows water service providers to manage the risks associated with service expansion to these areas. We argue that rather than a choice of the service provider alone, the decision for service differentiation should be seen as a consensus between different actors in the water services sector. A review of secondary data, and semi-structured interviews with diverse stakeholders in three Kenyan cities, show that managers of water utilities also choose these strategies because they appeal to and align with the interest of donors, governments, sector organisations, and alternative providers. 相似文献
This paper presents the results of a theoretical investigation into the effectiveness of a novel way to significantly reduce the fire protection cost to a composite beam. In this method, only the steel lower flange and a fraction of the steel web are protected. The effectiveness of a partially protected composite beam is assessed by comparing its plastic moment capacity with that of a fully protected beam subject to both the standard fire exposure and design fires.
The parametric time–temperature curves in Eurocode 1 are used to determine the time–temperature relationships of design fires. A finite element analysis computer program for heat transfer is used to evaluate the temperature field in the composite cross-section. The plastic moment capacity is calculated by dividing the composite cross-section into many small blocks and summing their contributions.
Partial protection is suitable for situations where the protection is applied along the steel profile. Results from this study indicate that the total fire protection cost may be reduced considerably due to more than 50% reduction in the protected surface area, despite similar material costs. 相似文献