Neonatal brain and cardiac imaging would benefit from the increased signal-to-noise ratio levels at 7 T compared to lower field. Optimal performance might be achieved using purpose designed RF coil arrays. In this study, we introduce an 8-channel dipole array and investigate, using simulations, its RF performances for neonatal applications at 7 T.
Methods
The 8-channel dipole array was designed and evaluated for neonatal brain/cardiac configurations in terms of SAR efficiency (ratio between transmit-field and maximum specific-absorption-rate level) using adjusted dielectric properties for neonate. A birdcage coil operating in circularly polarized mode was simulated for comparison. Validation of the simulation model was performed on phantom for the coil array.
Results
The 8-channel dipole array demonstrated up to 46% higher SAR efficiency levels compared to the birdcage coil in neonatal configurations, as the specific-absorption-rate levels were alleviated. An averaged normalized root-mean-square-error of 6.7% was found between measured and simulated transmit field maps on phantom.
Conclusion
The 8-channel dipole array design integrated for neonatal brain and cardiac MR was successfully demonstrated, in simulation with coverage of the baby and increased SAR efficiency levels compared to the birdcage. We conclude that the 8Tx-dipole array promises safe operating procedures for MR imaging of neonatal brain and heart at 7 T.
Modeling of musculoskeletal structures requires accurate data on anatomical parameters such as muscle lengths (MLs), moment arms (MAs) and those describing the upper limb position. Using a geometrical model of planar arm movements with three degrees of freedom, we present, in an analytical form, the available information on the relationship between MAs and MLs and joint angles for thirteen human upper limb muscles. The degrees of freedom included are shoulder flexion/extension, elbow flexion/extension, and either wrist flexion/extension (the forearm in supination) or radial/ulnar deviation (the forearm in mid-pronation). Previously published MA/angle curves were approximated by polynomials. ML/angle curves were obtained by combining the constant values of MLs (defined by the distance between the origin and insertion points for a specific upper limb position) with a variable part obtained by multiplying the MA (joint radius) and the joint angle. The MAs of the prime wrist movers in radial/ulnar deviation were linear functions of the joint angle (R2 > or = 0.9954), while quadratic polynomials accurately described their MAs during wrist flexion/extensions. The relationship between MAs and the elbow angle was described by 2nd, 3rd or 5th-order polynomials (R2 > or = 0.9904), with a lesser quality of fit for the anconeus (R2 = 0.9349). In the full range of angular displacements, the length of wrist, elbow and shoulder muscles can change by 8.5, 55 and 200%, respectively. 相似文献
OBJECTIVE: To assess how often the aetiology is established in patients with uveitis, what systemic disease are found and what is the contribution of the internist to the diagnostic process. DESIGN: Retrospective study. SETTING: University Hospital Leiden, the Netherlands. METHOD: From January 1987 to April 1992, 342 patients presented with uveitis. All patients underwent a standard ophthalmological examination. Referral to an internist and individualised laboratory screening followed in patients with recurrent, chronic, bilateral or panuveitis. Recorded were: ophthalmological data, results of laboratory screening, results of analysis by the internist, final diagnosis and presence of systemic disease. RESULTS: 149 (44%) patients were examined by the internist, 18 (5.2%) were seen by another specialist. In 169 (49%) patients a specific diagnosis was made. 74 (22%) had a systemic disease, 74 a primary ocular disease. In 28 (8%) a systemic disease was presumed (5% were HLA-B27 positive, 3% had abnormal laboratory results); 5 (1%) patients had endophthalmitis as a complication of a septic process. CONCLUSION: In approximately 1/3 of the patients with uveitis a systemic disease was found. Examination by the internist tailored to the individual patient is essential in the evaluation of uveitis patients. 相似文献
Airframe riveting is a critical process that requires high levels of process monitoring and quality assurance due to the very
high risk associated with the failure of such joints. This paper describes the development of the enabling technology developed
for a machine vision-based process monitoring system. One of the key factors affecting the performance of a machine vision
system is the quality of the lighting. In the application described in this paper the available lighting was severely limited
by the confined space in which the system had to operate. The problem was also compounded by the reflective nature of the
objects to be examined. The initial images obtained were not suitable for further processing due to the presence of significant
shadows and specular reflections. A novel solution to this problem based on multiple wavelength illumination and signal processing
is presented along with results from experimental trials of the approach. 相似文献
There is no better place to test life-saving resuscitation interventions than in the prehospital setting. Patients rarely survive cardiac arrest if resuscitation techniques have failed before leaving the scene. Also, paramedics are usually very experienced in key initial resuscitative techniques, and they routinely operate under strict paramilitary protocol, resulting in better study compliance. In addition, the large study populations that are derived from emergency medical services (EMS) systems lead to faster study completion and statistically stronger data. Most important, by reinforcing standardized care, rigidly scrutinized trials improve patient care, regardless of the effect of the study intervention. The success of productive EMS research centers requires routine communication between hospital and EMS administrators and their medical directors, designation of mutually acceptable data collectors who guarantee confidentiality, reciprocal exchange of study data provided as educational seminars to the hospitals, commitments to support the budget requests of an EMS program and appropriate system modifications, inclusion of EMS personnel in study design from the very beginning, prospective education of the medical community and media before protocol implementation, an authoritative grassroots medical director, and a paramedic supervisor system. 相似文献
The labile protons of two 32-base-pair, four-arm models of immobile Holliday junctions have been studied by two-dimensional 1H nuclear magnetic resonance (NMR) spectroscopy. Overlap of resonances in the imino-imino region of two-dimensional nuclear Overhauser enhancement (NOE) spectra necessitates the use of a multi-pathway approach for obtaining sequence-specific assignments wherein all possible NOE connectivities to the labile protons are utilized, including those from the 2H of adenine, 5CH3 of thymine, and 5H of cytosine. Resonance assignments are obtained for all slowly exchanging imino and cytosine amino protons. Base-pairing up to and including the junction point is found in all four arms of both Holliday junctions. Several cross-arm NOE connectivities are identified and can be used to infer the geometry of the helical stacking domains. The two Holliday junctions studied, which differ only by the exchange of two base pairs at the branch point, appear to have opposite arm stacking geometries. These assignments form an important part of the critical background for detailed NMR analysis of Holliday junction structure and dynamics. 相似文献