LiFe2/3Mn1/3PO4/C composite was prepared by the rheological phase reaction using LiH2PO4, Li2CO3, FePO4, Mn(Ac)2·4H2O and ascorbic acid as starting materials. The crystal structure and morphology of as-synthesized sample were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The analysis of XRD results showed that the obtained sample was single-phase with orthorhombic olivine-type structure (Pnma space group). SEM micrographs revealed that the sample was aggregates, with an irregular morphology. The initial discharge capacity was 166.9, 149.1, 139.6, 112.8, 82.93 mAh g??1 at the rate of 0.1, 0.5, 1, 2, and 10 C, respectively. And when the rate was 0.1, 0.5, 1, 2, and 10 C, the capacity retention was 92.2%, 90%, 92.9%, 97.6%, 91.5% after 50, 100, 200, 200, 500 cycles, respectively.
In this article, an adaptive fuzzy output feedback control method is presented for nonlinear time-delay systems with time-varying full state constraints and input saturation. To overcome the problem of time-varying constraints, the integral barrier Lyapunov functions (IBLFs) integrating with dynamic surface control (DSC) are applied for the first time to keep the state from violating constraints. The effects of unknown time delays can be removed by using designed Lyapunov-Krasovskii functions (LKFs). An auxiliary design system is introduced to solve the problem of input saturation. The unknown nonlinear functions are approximated by the fuzzy logic systems (FLS), and the unmeasured states are estimated by a designed fuzzy observer. The novel controller can guarantee that all signals remain semiglobally uniformly ultimately bounded and satisfactory tracking performance is achieved. Finally, two simulation examples illustrate the effectiveness of the presented control methods. 相似文献
采用ETAG 004:2013《外墙外保温薄抹灰系统欧洲技术认证指南》中规定的静态泡沫块法,测试在单位面积上使用不同数量锚栓的岩棉板外保温系统的抗风压性能。通过试验可以得出:在混凝土墙体上单纯采用敲击式锚栓锚固岩棉板外保温系统时,拉伸强度可达12.9 k Pa;单位面积增加锚栓的使用量可以提高系统的抗拉承载力,但在不同条件下增加相同数量锚栓对系统抗风载能力提高的程度不同;在普通混凝土墙中,单纯锚固岩棉板保温系统破坏时,单个锚栓承载力平均值的最大值约为其拉拔承载力的50.3%。 相似文献
There are many potential causes of corrosion in animal buildings. Animals exhale large quantities of moisture into the air creating high relative humidity in the building if the moisture is not properly vented. High humidity increases the potential for condensation. In addition, ammonia may be found in large quantities in animal buildings. Ammonia is released from manure and urine. In addition, ammonium chloride is used as a nitrogen source in fertilisers. In this study, the atmospheric corrosion of hot-dip-galvanised steel and zinc alloy-coated steel such as zinc–aluminium and zinc–aluminium–magnesium has been studied in atmospheres containing different levels of ammonia. Investigations have also been conducted at different levels of ammonium chloride. The results are discussed in view of the mechanisms of corrosion of zinc and zinc alloy-coated steel in ammonia and ammonium chloride-containing environments. 相似文献