Currently, the efficient detection of fingerprints is essential for the crime investigations. Revealing fingerprints is commonly achieved with fluorescent organic compounds but they are not efficient for fingerprint detection on porous or reflective surfaces. In order to solve the problem of collecting fingerprints on porous/reflective surfaces, inorganic phosphors have been employed, since they have characteristics of variable color emission, afterglow, high chemical stability and nano-size, which allow the fingerprint detection on any porous or non-porous surfaces. Due to these last properties, this review presents a summary about the use of phosphorescent and fluorescent phosphors for the detection of latent fingerprints. First, we discussed the main physical and chemical characteristics of the fingerprints which permit their detection and collection from any surface. After this, we presented the main morphological, structural and luminescent properties of the phosphorescent and fluorescent phosphors that allow their use for fingerprint detection. Later, we demonstrated with pictures of fingerprints (with and without light emission from the phosphors deposited on them) that both, phosphorescent and fluorescent phosphors can be used to visualize fingerprints with high resolution and high contrast without interference of the background surface, which is ideal for its collection and registration in the Automated Fingerprint Identification System (AFIS). We believe that this review could be useful to understand how to select an appropriate phosphorescent or fluorescent material for fingerprint detection depending on the type of surface (porous or non-porous, reflective or not reflective) where the fingerprint is deposited. 相似文献
Senescent cells accumulate in the adipose tissue (AT) of individuals with obesity and secrete multiple factors that constitute the senescence-associated secretory phenotype (SASP). This paper aimed at the identification of B cells with a SASP phenotype in the AT, as compared to the peripheral blood, of individuals with obesity. Our results show increased expression of SASP markers in AT versus blood B cells, a phenotype associated with a hyper-metabolic profile necessary to support the increased immune activation of AT-derived B cells as compared to blood-derived B cells. This hyper-metabolic profile is needed for the secretion of the pro-inflammatory mediators (cytokines, chemokines, micro-RNAs) that fuel local and systemic inflammation. 相似文献
In this work, p-NiO/n-ZnO heterostructures were successfully prepared at room temperature using RF sputtering technique. The influence of ZnO layer thickness on the performance of the heterojunction was investigated. The deposited ZnO layers have a hexagonal Wurtzite structure with preferable growth orientations along (002) and (103) for thinner films. Increasing the thickness results in more crystallographic orientation randomness. The current–voltage measurements of the realized heterojunctions showed a clear rectifying behavior. The measured ideality factor varies from 2.5 to 1.6 according to the thickness of ZnO layer. The series resistance of the device is enlarged with increasing ZnO thickness. The deduced parameters from the I–V characteristics suggest that 200 nm is the optimal thickness of the ZnO layer according to our experimental conditions. We attribute the relatively better performance of this thickness to achieving reasonable compensation between serial resistance and ideality factor. The best heterojunction was tested and successfully used as a UV detector. 相似文献
4-Amino-3-thio-1,24-triazolidine (L1) and 4-amino-5-thio-1,3,4-thiadiazole (LII) as well as their metal complexes of the general formulae MLI·2H2O and MLIICl (M; Pb(II), Cd(II) and Zn(II)) were prepared. With Sn(II), we obtained Sn(LI)2·2H2O and SnLIICl, respectively. The structures of the compounds were identified through elemental analysis, and IR and UV spectra measurements, in addition to thermal analysis in case of the metal complexes. The antifouling properties of the compounds were tested by their incorporation into paint formulations which were applied to PVC substrates and tested in water from Alexandria western harbour. When the compounds were added at 17·5% by volume, the coated panels were fouled after 3 months of immersion. The addition of 6·7% by volume of tributyltin oxide to 15·8% of the prepared compounds in one formulation elevated the paint efficiency and prevented fouling for 11 months. Paint containing solely tributyltin oxide at the same concentration was inactive against algae. 相似文献
BACKGROUND: The establishment of the nasopharyngeal flora was followed in Costa Rican children from birth to 1 year of age. METHODS: Nasopharyngeal cultures were obtained at 1 (n = 413), 3 (n = 393), 6 (n = 376) and 12 months (n = 356) of age from children representative of the population in the Puriscal district. Weekly cultures were obtained from a subcohort of these children (n = 101). Mother-infant diads (n = 95) and preschool children (n = 208) attending day-care centers were also studied. RESULTS: The estimated proportion of colonized children in the population differed markedly depending on the frequency of culture. Quarterly cultures showed a slow increase in carrier rates from 3.9% for Haemophilus influenzae, 3.1% for Streptococcus pneumoniae and 6.5% for Moraxella catarrhalis at 1 month of age to 10.1% carrying H. influenzae and 19.4% carrying S. pneumoniae by the end of the first year. By quarterly culture the proportion of children colonized at least once was 36% for S. pneumoniae, 26% for H. influenzae and 28% for M. catarrhalis. In contrast weekly sampling showed that 95 to 100% of the children were colonized at least once during the first year of life with H. influenzae, S. pneumoniae or M. catarrhalis. Nasopharyngeal carriage of H. influenzae, S. pneumoniae and M. catarrhalis was low in the mothers, and very few mother-infant pairs carried identical bacteria at the same time. In contrast carrier rates were high in the siblings attending day care (H. influenzae 27.9%, S. pneumoniae 39.4%, both organisms 26.6%). Infants with siblings had significantly higher bacterial carriage at all ages than infants without siblings. CONCLUSIONS: Quarterly nasopharyngeal cultures showed that Costa Rican infants acquire their nasopharyngeal flora at a rate comparable with that for infants in developed countries and that siblings are an important source of the bacteria. Weekly samplings showed that virtually all children were colonized at least once during the first year of life. 相似文献
A CEC-funded project has been performed to tackle the problem of producing an advanced Life Monitoring System (LMS) which would calculate the creep and fatigue damage experienced by high temperature pipework components. Four areas were identified where existing Life Monitoring System technology could be improved:
1. 1. the inclusion of creep relaxation
2. 2. the inclusion of external loads on components
3. 3. a more accurate method of calculating thermal stresses due to temperature transients
4. 4. the inclusion of high cycle fatigue terms.
The creep relaxation problem was solved using stress reduction factors in an analytical in-elastic stress calculation. The stress reduction factors were produced for a number of common geometries and materials by means of non-linear finite element analysis. External loads were catered for by producing influence coefficients from in-elastic analysis of the particular piping system and using them to calculate bending moments at critical positions on the pipework from load and displacement measurements made at the convenient points at the pipework. The thermal stress problem was solved by producing a completely new solution based on Green's Function and Fast Fourier transforms. This allowed the thermal stress in a complex component to be calculated from simple non-intrusive thermocouple measurements made on the outside of the component. The high-cycle fatigue problem was dealt with precalculating the fatigue damage associated with standard transients and adding this damage to cumulative total when a transient occurred.
The site testing provided good practical experience and showed up problems which would not otherwise have been detected. 相似文献