Romanian policy makers have to perceive that human intervention on river basins land cover is influencing rainfall-runoff relation and the used methodology cannot accurately estimate watershed surface flow transformations. Global water cycles and energy fluxes understanding is leading to better predictions of land atmosphere interaction and local hydro-climates evolution. The water transfer time determination from rainfall to runoff needs accurate measurements of river basins hydrological parameters. Here, we analyzed and compared the lag time value results of two different methodologies (curve number and rational methodology) used for 54 Romanian small catchment areas study. The focus of this paper is the lag time evaluation and interpretation for an effective implementation of the best methodology approach in the Romanian geographical space. Our research in small river basins was developed using remote sensing technology maps, GIS and environmental datasets in combination with field work on every drainage basin in order to assess the specific morphological features and validate the land cover typology. We found that Soil Conservation Service - Curve Number (SCS-CN) method is widely used according to USA landscape features classification, but not necessarily applicable to Romanian river basins characteristics. Our results show how the official Romanian rational methodology national standard (RNS) can be improved and the limits of SCS-CN method.
This study investigated the effect on vertical bone regeneration of the addition of demineralized freeze-dried bone allograft or autogenous bone chips to a membrane technique. Twenty partially edentulous patients with vertical jawbone deficiencies were selected for this study. The patients were divided into two groups of 10 individuals. The 10 patients of Group A received 26 Br?nemark implants in 10 surgical sites. The 10 patients of Group B received 32 implants in 12 surgical sites. Fifty-two out of 58 implants (22 in Group A and 30 in Group B) extended 1.5 to 7.5 mm superior to the bone crest. Titanium-reinforced expanded polytetrafluoroethylene membranes were used to cover the implants and, before complete membrane fixation, demineralized freeze-dried bone allograft particles were condensed under the membrane in Group A, and autogenous bone chips were used in Group B. At the reentry after 7 to 11 months the membranes were removed and a small biopsy was collected from 11 sites comprehending the miniscrews. The clinical measurements from Group A demonstrated a mean vertical bone gain of 3.1 mm (SD = 0.9 mm, range 1 to 5 mm) with a mean percentage of bone gain of 124% (SD = 46.6%). The measurements from Group B showed a mean vertical bone gain of 5.02 mm (SD = 2.3 mm, range 1 to 8.5 mm) with a mean percentage of bone gain of 95% (SD = 26.8%). Histomorphometric analysis of the present study clearly demonstrated a direct correlation between the density of the pre-existing bone and the density of the regenerated bone. The mean percentage of new bone-titanium contact was from 39.1% to 63.2%, depending on the quality of the pre-existing bone. Both the clinical and histologic results indicate a beneficial effect of the addition of demineralized freeze-dried bone allograft or autogenous bone particles to vertical ridge augmentation procedures in humans. 相似文献
Presented in part at the 58th Annual Meeting of the American Academy of Dermatology, 2000, and at the Annual Scientific Meeting of the Society of Cosmetic Chemists, December 2000 Assays of moisturizer efficacy have traditionally focused on a moisturizer's ability to alleviate dry skin. More recently, a moisturizer's ability to prevent primary irritation has been recognized. To assess and compare the ability of moisturizers to alleviate skin dryness and primary irritation, as well as prevent their return, four controlled-application clinical ( in vivo ) studies were carried out: hand-wash test, regression test, reduction in pre-existing irritation study, and prevention-of-irritation studies. Overall conclusions were confirmed in a home-use clinical (validation) study of people suffering from mild eczema. The controlled in vivo studies demonstrate that: (a) a moisturizer can alleviate skin dryness and irritation, and prevent their return; and (b) the efficacy of different moisturizers can be differentiated, based on their composition. The home-use study results demonstrated that the most effective moisturizer identified by the controlled-application studies was highly effective against the signs of eczema. In vivo modelling of moisturizer efficacy enables assessment and optimization of different benefits separately, while predicting the quantitative and perceived (observed) relevance of the benefits the moisturizer delivers to consumers. 相似文献
We report here the synthesis and structural characterization of novel cationic (phenothiazinyl)vinyl-pyridinium (PVP) dyes, together with optical (absorption/emission) properties and their potential applicability as fluorescent labels. Convective heating, ultrasound irradiation and mechanochemical synthesis were considered as alternative synthetic methodologies proficient for overcoming drawbacks such as long reaction time, nonsatisfactory yields or solvent requirements in the synthesis of novel dye (E)-1-(3-chloropropyl)-4-(2-(10-methyl-10H-phenothiazin-3-yl)vinyl)pyridin-1-ium bromide 3d and its N-alkyl-2-methylpyridinium precursor 1c. The trans geometry of the newly synthesized (E)-4-(2-(7-bromo-10-ethyl-10H-phenothiazin-3-yl)vinyl)-1-methylpyridin-1-ium iodide 3b and (E)-1-methyl-4-(2-(10-methyl-10H-phenothiazin-3-yl)vinyl)pyridin-1-ium tetrafluoroborate 3a′ was confirmed by single crystal X-ray diffraction. A negative solvatochromism of the dyes in polar solvents was highlighted by UV-Vis spectroscopy and explanatory insights were supported by molecular modeling which suggested a better stabilization of the lowest unoccupied molecular orbitals (LUMO). The photostability of the dye 3b was investigated by irradiation at 365 nm in different solvents, while the steady-state and time-resolved fluorescence properties of dye 3b and 3a′ in solid state were evaluated under one-photon excitation at 485 nm. The in vitro cytotoxicity of the new PVP dyes on B16-F10 melanoma cells was evaluated by WST-1 assay, while their intracellular localization was assessed by epi-fluorescence conventional microscopy imaging as well as one- and two-photon excited confocal fluorescence lifetime imaging microscopy (FLIM). PVP dyes displayed low cytotoxicity, good internalization inside melanoma cells and intense fluorescence emission inside the B16-F10 murine melanoma cells, making them suitable staining agents for imaging applications. 相似文献
Multiwalled carbon nanotubes have been produced from H2-C2H4 mixtures on Fe-SiO2 catalysts by a fluidized bed catalytic chemical vapor deposition process. Various parameters such as the catalyst preparation, the residence time, the run duration, the temperature, the H2:C2H4 ratio, the amount of metal deposited on the support have been examined. The influence of these parameters on the deposited carbon yield is reported, together with observations of the produced material. This process allows an homogeneously distributed deposition of nanotubes (10-20 nm diameter), that remain anchored to the support. 相似文献
An ultrasonic technique was developed to study the crystallization process of edible fats on-line. A chirp wave was used instead
of the conventional pulser signal, thus achieving a higher signal-to-noise ratio. This enabled measurements to be made in
concentrated systems [≈20% solid fat content (SFC)] through a 8.11-cm thick sample without significant signal loss. Fat samples
were crystallized at 20, 25, and 30°C at a constant agitation rate of 400 rpm for 90 min. The crystallization process was
followed by ultrasonic spectroscopy and a low-resolution pulsed nuclear magnetic resonance spectrometer. Specific relationships
were found between ultrasonic parameters [integrated response, time of flight (TF), and full width half maximum] and SFC.
TF, which is an indirect measurement of the ultrasonic velocity (v), was highly correlated to SFC (r2>0.9) in a linear fashion (v=2.601 SFC+1433.0). 相似文献
State feedback control is very attractive due to the precise computation of the gain matrix, but the implementation of a state feedback controller is possible only when all state variables are directly measurable. This condition is almost impossible to accomplish due to the excess number of required sensors or unavailability of states for measurement in most of the practical situations. Hence, the need for an estimator or observer is obvious to estimate all the state variables by observing the input and the output of the controlled system. As such, the goal of this paper is to provide a control design methodology based on a Luenberger observer design that can assure the closed-loop performances of a vehicle drivetrain with backlash, while compensating the network-enhanced time-varying delays. This goal is achieved in a sequential manner: firstly, a piecewise linear model of two inertias drivetrain, which takes into consideration the backlash nonlinearity and the network-enhanced time-varying delay effects is derived; then, a Luenberger observer which estimates the state variables is synthesized and the robust full state-feedback predictive controller based on flexible control Lyapunov functions is designed to explicitly take into account the bounds of the disturbances caused by time-varying delays and to guarantee also the input-to-state stability of the system in a non-conservative way. The full state-feedback predictive control strategy based on the Luenberger observer design was experimentally tested on a vehicle drivetrain emulator controlled through controller area network, with the aim of minimizing the backlash effects while compensating the network-enhanced delays. 相似文献
In this paper the testability of modified-Booth array multipliers for standard cells based design environments is examined for first time. In such cases the structure of the cells may be unknown, thus Cell Fault Model (CFM) is adopted. Two C-testable designs are proposed. A design for an Nx × Ny bits modified-Booth multiplier, which uses ripple carry addition at the last stage of the multiplication, is first proposed. The design requires the addition of only one extra primary input and 38 test vectors with respect to CFM. A second C-testable design is given using carry lookahead addition at the last stage which is the case of practical implementations of modified-Booth multipliers. Such a C-testable design using carry lookahead addition is for first time proposed in the open literature. This second design requires the addition of 4 extra primary inputs. One-level and two-levels carry lookahead adders, are considered. The C-testable design requires 61 test vectors for the former and 73 test vectors for the latter, respectively. The hardware and delay overheads imposed by both C-testable designs are very small and decrease when the size of the multiplier increases. 相似文献