首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   32篇
  免费   2篇
化学工业   5篇
机械仪表   3篇
建筑科学   2篇
能源动力   1篇
轻工业   1篇
无线电   2篇
一般工业技术   8篇
冶金工业   9篇
原子能技术   1篇
自动化技术   2篇
  2020年   1篇
  2017年   1篇
  2016年   1篇
  2015年   2篇
  2014年   2篇
  2012年   3篇
  2011年   2篇
  2009年   2篇
  2008年   2篇
  2007年   3篇
  2006年   3篇
  1998年   6篇
  1997年   2篇
  1994年   1篇
  1993年   1篇
  1982年   1篇
  1977年   1篇
排序方式: 共有34条查询结果,搜索用时 15 毫秒
1.
This paper investigates the influence of the position of the antennas in a dual-radio mesh router by characterizing the router components from an electromagnetic point of view. Since the behavior of a wireless router equipped with multiple devices and antennas can be affected by mutual coupling among several close conducting bodies, numerical and experimental tests are carried out to provide some suggestions for an accurate positioning of the antennas. A reference configuration is implemented in an electromagnetic Computer-Aided Design (CAD) simulator. The most significant numerical results are validated by performing a campaign of measurements in anechoic chamber and deploying a testbed for the derivation of the experimental values of throughput, return loss, power density, and directivity.  相似文献   
2.
The methyllysine reader protein Spindlin1 has been implicated in the tumorigenesis of several types of cancer and may be an attractive novel therapeutic target. Small‐molecule inhibitors of Spindlin1 should be valuable as chemical probes as well as potential new therapeutics. We applied an iterative virtual screening campaign, encompassing structure‐ and ligand‐based approaches, to identify potential Spindlin1 inhibitors from databases of commercially available compounds. Our in silico studies coupled with in vitro testing were successful in identifying novel Spindlin1 inhibitors. Several 4‐aminoquinazoline and quinazolinethione derivatives were among the active hit compounds, which indicated that these scaffolds represent promising lead structures for the development of Spindlin1 inhibitors. Subsequent lead optimization studies were hence carried out, and numerous derivatives of both lead scaffolds were synthesized. This resulted in the discovery of novel inhibitors of Spindlin1 and helped explore the structure–activity relationships of these inhibitor series.  相似文献   
3.
Nitsche’s method for two and three dimensional NURBS patch coupling   总被引:2,自引:0,他引:2  
We present a Nitche’s method to couple non-conforming two and three-dimensional non uniform rational b-splines (NURBS) patches in the context of isogeometric analysis. We present results for linear elastostatics in two and and three-dimensions. The method can deal with surface-surface or volume-volume coupling, and we show how it can be used to handle heterogeneities such as inclusions. We also present preliminary results on modal analysis. This simple coupling method has the potential to increase the applicability of NURBS-based isogeometric analysis for practical applications.  相似文献   
4.
In this paper we describe the one-pot fabrication of hydroxyapatite (HA)-heparin composites by electrodeposition onto Ti substrates and their characterisation in terms of structure, morphology, heparin content and bioactivity. HA coatings are well known and widely applied osteointegration enhancers, but post-implant healing rate in dental applications is still suboptimal: e.g. coagulation control plays a key role and the incorporation of an anticoagulant is considered a highly desirable option. In this study, we have developed an improved, simple and robust growth procedure for single-phase, pure HA-heparin films of thickness 1/3 μm. HA-heparin, forming nanowires, has the ideal morphology for bone mineralisation. Staining assays revealed homogeneous incorporation of sizable amounts of heparin in the composite films. The bioactivities of the HA and HA-heparin coatings on Ti were compared by HeLa cell proliferation/viability tests and found to be enhanced by the presence of the anticoagulant.  相似文献   
5.
The Vane method (Vane test) is a simple but efficient method to measure the yield stress among other properties of non-Newtonian fluids. These fluids exhibit big flow effects in flat surfaces which are common in rheometers devices of different types (parallel disk or coaxial cylinder types). The yield stress values obtained with Vane method, in pastes, gels, soils and concentrated suspensions, have presented good agreement with results found elsewhere by most of the rheologic methods shown in the literature. The aim of this work is presenting a discussion on the capabilities of the Vane method, highlighting the theoretical basis, the functioning principle with some operational particularities, and some applications of the method in investigating the properties of fresh rendering mortars.  相似文献   
6.
In dental applications, the contact between the metal implant and the receiving living tissue is made through the oxide layer on the implant surface, which allows the osseointegration process. In dentistry, the passive film formed on titanium seems to be more stable and protective than that formed on the Ti alloys, customarily used in other medical applications. Corrosion of titanium alloys in the mouth can result from the presence of a number of corrosive species, such as the hydrogen ion (H(+)), sulfide compounds (S(2-)), dissolved oxygen (O(2)) and Cl(-) and can result in the release of Ti(4+) ions that, in turn, brings about the reduction of alkaline phosphatase activity of osteoblastic cells. The present study reports a time-dependent electrochemical corrosion study of titanium in contact with the following biologically relevant solutions: (i) SBF (simulating the inorganic part of human plasma), (ii) SBF with added ovalbumin (a protein simulating the post-implant environment) and (iii) human plasma. To the best of the authors' knowledge, this is the first report on the corrosion of Ti in human plasma. The electrochemical measurements are based on electrochemical impedance spectrometry. Impedance spectra were interpreted on the basis of the equivalent-circuit approach and estimates of the time-variation of oxide film thickness and resistance were computed. Surface Raman spectroscopy was used to characterise the structure of as-anodised and corroded TiO(2) films: the effects of phosphate and organic incorporation were highlighted. EIS and surface Raman measurements have demonstrated that the corrosion resistance of the oxide films formed on Ti is strongly affected by the presence of biomolecules in the chloride- and phosphate-based aqueous solution. In particular, ovalbumin increases corrosion performance and human plasma is found to be remarkably more aggressive in comparison to SBF. These results suggest some caution in extrapolating corrosion results obtained in simulated biological fluids to the actual behaviour in vivo.  相似文献   
7.
Colloidal semiconductor-magnetic hybrid nanocrystals with topologically controlled composition are fabricated by heterogeneous nucleation of spherical epsilon-Co domains onto anatase TiO2 nanorods. The latter can be selectively decorated at either their tips or at multiple locations along their longitudinal sidewalls, forming lattice-matched heterointerfaces regardless of the metal deposition sites. The possibility of switching between either heterostructure growth modes arises from the facet-dependent chemical reactivity of the oxide seeds, which is governed mainly by selective adhesion of the surfactants rather than by small differences in misfit-induced interfacial strain at the relevant junction points.  相似文献   
8.
Ongoing developments in cardiac modelling have resulted, in particular, in the development of advanced and increasingly complex computational frameworks for simulating cardiac tissue electrophysiology. The goal of these simulations is often to represent the detailed physiology and pathologies of the heart using codes that exploit the computational potential of high-performance computing architectures. These developments have rapidly progressed the simulation capacity of cardiac virtual physiological human style models; however, they have also made it increasingly challenging to verify that a given code provides a faithful representation of the purported governing equations and corresponding solution techniques. This study provides the first cardiac tissue electrophysiology simulation benchmark to allow these codes to be verified. The benchmark was successfully evaluated on 11 simulation platforms to generate a consensus gold-standard converged solution. The benchmark definition in combination with the gold-standard solution can now be used to verify new simulation codes and numerical methods in the future.  相似文献   
9.
By combining in situ X-ray photoemission spectroscopy, ex situ high resolution transmission electron microscopy, scanning electron microscopy, and Raman spectroscopy, we show that chemical vapor deposition (CVD) on vertically aligned ZnO nanorods can synthesize different carbon nanostructures (CNs), whose morphology is driven by the ZnO nanorods and whose dimensions and structures change as a function of the process temperature. The CNs range from amorphous carbon cups, completely covering the nanorods, to high density one-dimensional carbon nano-dendrites (CNDs), which start to appear like short hairs on the ZnO nanorods. The nanorods are partially etched when the process is done at 630–800 °C, while they are completely etched at temperatures higher than 800 °C. In the latter case, CNDs emerge from a porous carbon sponge formed at the substrate interface but they are preferentially aligned along the location of the pristine ZnO nanorods. When used as a chemiresisitor the CND–ZnO structures have a higher sensitivity to ammonia compared to chemiresistors made by bare ZnO nanorods, to other one-dimensional CNs, like carbon nanotubes or other metal/metal-oxides hybrid CNs.  相似文献   
10.
International Journal on Software Tools for Technology Transfer - Decision diagrams (DDs) are widely used in system verification to compute and store the state space of finite discrete events...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号