全文获取类型
收费全文 | 64篇 |
免费 | 1篇 |
专业分类
电工技术 | 2篇 |
化学工业 | 20篇 |
金属工艺 | 1篇 |
机械仪表 | 4篇 |
能源动力 | 8篇 |
轻工业 | 3篇 |
一般工业技术 | 10篇 |
冶金工业 | 3篇 |
原子能技术 | 8篇 |
自动化技术 | 6篇 |
出版年
2023年 | 1篇 |
2022年 | 2篇 |
2021年 | 5篇 |
2020年 | 1篇 |
2019年 | 3篇 |
2018年 | 2篇 |
2017年 | 2篇 |
2016年 | 4篇 |
2015年 | 1篇 |
2014年 | 7篇 |
2013年 | 8篇 |
2012年 | 2篇 |
2011年 | 6篇 |
2010年 | 2篇 |
2009年 | 2篇 |
2008年 | 2篇 |
2005年 | 2篇 |
2003年 | 2篇 |
2002年 | 2篇 |
2001年 | 4篇 |
2000年 | 2篇 |
1995年 | 1篇 |
1994年 | 1篇 |
1977年 | 1篇 |
排序方式: 共有65条查询结果,搜索用时 15 毫秒
1.
Katsuhiro Inomata Daisuke NakanishiAi Banno Eiji NakanishiYosuke Abe Ryuta KuriharaKentaro Fujimoto Takuhei Nose 《Polymer》2003,44(18):5303-5310
Association behavior and physical gelation mechanism of ABA triblock copolymer dissolved in B-selective solvent have been studied systematically from dilute to moderately concentrated solutions. Static and dynamic light scattering and nuclear magnetic resonance measurements for dilute solutions of poly(methyl methacrylate)-block-poly(tert-butyl acrylate)-block-poly(methyl methacrylate) (PMMA-PtBuA-PMMA) in 1-butanol (PtBuA selective solvent) indicated that PMMA-PtBuA-PMMA chains are molecularly dissolved above 50 °C. With decreasing temperature, the triblock copolymers form associated micelles consisting PMMA associated core and PtBuA shell. Linear dynamic viscoelastic measurements for solutions with moderate concentration (3.9-12.0 wt%) revealed that the system was viscous sol state at 60 °C. Drastic increase of shear storage modulus (G′) occurred with decreasing temperature, and at 25 °C, G′ showed rubbery plateau with weak frequency dependency, means the formation of elastic physical gel. The consistency between the temperature for micelle formation and that at the increase in G′ indicates that the physical gelation is owing to the network formation as the result of the association of PMMA chains and the bridging PtBuA chains connecting the PMMA cores. Master curves for the dynamic moduli were derived by time-temperature superposition along the frequency axis. Just above sol-gel transition concentration (Cgel), the master curves suggest the existence of fairy amount of aggregate that is not incorporated in the macroscopic network. With the increase in polymer concentration, the master curves become to reveal Maxwell-type viscoelasticity with narrow relaxation time distribution, suggesting the formation of transient network with easily generation and destruction of crosslinks. Concentration dependency of the plateau modulus is stronger than the theoretically expected, means the macroscopic transient network grows with polymer concentration by increasing the fraction of elastically effective bridging PtBuA chain above Cgel. 相似文献
2.
In recently developed intelligent vehicles, warning alarms are often used to prompt avoidance behaviours from drivers facing imminent hazardous situations. However, when critical reaction delays to auditory stimulation are anticipated, the alarm should be activated earlier to compensate for such delays. It was found that reaction times to an auditory stimulus significantly increased in the presence of slow eye movement (SEM), which is known to occur frequently during the wake-sleep transition. The reaction delay could not be attributed to temporal effects such as fatigue and was invariant regardless of response effectors (finger or foot). Moreover, it was found that applied pedal force decreased immediately after an auditory stimulus interrupted SEM. Consequently, it was concluded that SEM can be a good predictor of reaction delays to auditory warning alarms when drivers are in a drowsy state. STATEMENT OF RELEVANCE: The present study demonstrated that simple auditory reaction time significantly increased when SEM emerged. In the design of vehicle safety systems using warning alarms to prompt avoidance behaviours from drivers, such reaction delays during SEM must be taken into account. 相似文献
3.
Ryuta Shigefuku Hideaki Takahashi Hiroyasu Nakano Tsunamasa Watanabe Kotaro Matsunaga Nobuyuki Matsumoto Masaki Kato Ryo Morita Yousuke Michikawa Tomohiro Tamura Tetsuya Hiraishi Nobuhiro Hattori Yohei Noguchi Kazunari Nakahara Hiroki Ikeda Toshiya Ishii Chiaki Okuse Shigeru Sase Fumio Itoh Michihiro Suzuki 《International journal of molecular sciences》2016,17(9)
The progression of chronic liver disease differs by etiology. The aim of this study was to elucidate the difference in disease progression between chronic hepatitis C (CHC) and nonalcoholic fatty liver disease (NAFLD) by means of fibrosis markers, liver function, and hepatic tissue blood flow (TBF). Xenon computed tomography (Xe-CT) was performed in 139 patients with NAFLD and 152 patients with CHC (including liver cirrhosis (LC)). The cutoff values for fibrosis markers were compared between NAFLD and CHC, and correlations between hepatic TBF and liver function tests were examined at each fibrosis stage. The cutoff values for detection of the advanced fibrosis stage were lower in NAFLD than in CHC. Although portal venous TBF (PVTBF) correlated with liver function tests, PVTBF in initial LC caused by nonalcoholic steatohepatitis (NASH-LC) was significantly lower than that in hepatitis C virus (C-LC) (p = 0.014). Conversely, the liver function tests in NASH-LC were higher than those in C-LC (p < 0.05). It is important to recognize the difference between NAFLD and CHC. We concluded that changes in hepatic blood flow occurred during the earliest stage of hepatic fibrosis in patients with NAFLD; therefore, patients with NAFLD need to be followed carefully. 相似文献
4.
Iwao Matsuya Ryota Tomishi Maya Sato Kiyoshi Kanekawa Yoshihiro Nitta Motoichi Takahashi Satoru Miura Yasutsugu Suzuki Tomohiko Hatada Ryuta Katamura Takashi Tanii Shuichi Shoji Akira Nishitani Iwao Ohdomari 《IEEJ Transactions on Electrical and Electronic Engineering》2011,6(3):266-272
We have developed a novel sensor that enables us to measure the relative story displacement of a building structure in real time. This lateral displacement sensor (LDS) is composed of a light‐emitting diode (LED) array, which is fixed on the ceiling, and a position‐sensitive detector (PSD) unit, which is placed on the floor. We optimized the LDS to achieve high accuracy in lateral displacement measurement. The accuracy was evaluated to be 60 µm by conducting shaking table tests. Two LDSs were implemented in an actual building equipped with an active variable stiffness (AVS) system, and the building was vibrated with seismic waveforms by an exciter placed on the rooftop. The seismic displacement of the second floor relative to the first floor was measured using the LDS. Furthermore, the inclination angle of the second floor could be measured using the LDS during the seismic vibration. Using the AVS system, we realized the residual displacement of the second floor without inducing damage to the building, and succeeded in real‐time residual displacement measurement for the first time. These results indicate that the LDS is useful for the health diagnosis of a building structure. © 2011 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc. 相似文献
5.
This paper proposes an optimal impedance control method for a variable stiffness actuator (VSA), in which a variable stiffness mechanism and an actuator are aligned in series. First, we introduce a circuit expression of the robotic system and provide a unified framework to determine an optimal index of robots driven by VSAs, irrespective of the presence or absence of the environment. Next, we design a torque controller for a one-degree-of-freedom (DOF) robot and find the optimal condition of the stiffness in the VSA for a given task. Then, we design a stiffness control law for the VSA exploiting the intrinsic indivisible property between motion and passive impedance. This stiffness control law adaptively tunes the passive stiffness to minimize the energy consumption without defining any explicit desired impedance, which is usually required in impedance controllers. The stability of the closed loop system is proved using Lyapunov’s analysis. Simulations and experimental results validate the effectiveness of the proposed method and the robustness in response to parameter changes. 相似文献
6.
This article presents a study of the effect of through-the-thickness stitching yarns upon the strength and failure behavior
of multidirectionally reinforced composites. The in-plane yarns were placed in four directions (0,±45, 90) to form a quasi-isotropic
preform, which had open spaces between adjacent yarns. These interyarn spaces allowed easy insertion of the through-the-thickness
stitching yarns without significant damage of the in-plane fibers. Fiber volume fractions of over 54 pct were obtained by
this method. The through-the-thickness yarn sizes used in this study were 2, 4, and 6 kilo-filament (kf). Non-stitched performs
were also manufactured with the same fiber content and by the same procedure as the stiched preforms for the control experiments.
All preforms were infiltrated with epoxy resin by the resin transfer molding (RTM) technique. In-plane tensile and compressive
strength, interlaminar shear strength, and mode I fracture toughness of the carbon/epoxy composites were measured at three
through-the-thickness yarn contents. Although the through-the-thickness yarns significantly enhanced the mode I fracture toughness,
they tended to degrade the in-plane tensile and compressive strength. The failure process under interlaminar shear loading
by double notch shear tests showed two distinct stages: the fiber-matrix interfacial failure followed by the breakage/debonding
of the through-the-thickness yarns. The through-the-thickness yarns caused a reduction of the initial failure load in the
first stage but could enhance the final failure load in the second stage. In composites with 6 kf through-the-thickness yarns,
the final failure load could exceed the initial failure load. Scanning electron microscope (SEM) and optical microscopic examinations
were also conducted for observing the failure mechanisms and fracture surfaces.
This article is based on a presentation made in the Symposium “Mechanisms and Mechanics of Composites Fracture” held October
11–15, 1998, at the TMS Fall Meeting in Rosemont, Illinois, under the auspices of the TMS-SMD/ASM-MSCTS Composite-Materials
Committee. 相似文献
7.
In our previous study, the effects of the interval between the cylinder and the airfoil on the aerodynamic sound were investigated and compared with the cases of single circular and single airfoil. In this study, the effects of the attack angle of the airfoil located downstream on the characteristics of aerodynamic sound and the wake structure are investigated at a given interval between the cylinder and the airfoil. It is found that the sound pressure level of DFN and the peak frequency decrease with increasing attack angle of airfoil because of the diffusive wake structure due to the increased back pressure of circular cylinder, which is caused by the blocking effect of airfoil. It is shown that the sound sources are corresponded to the attack points of shedding vortex form the upstream circular cylinder to the downstream airfoil. We conclude that the pressure fluctuation at the airfoil surface effects on the sound pressure level, from the flow visualizations and the exploration test of sound source. 相似文献
8.
Yasuto Kunii Junya Matsumoto Ryuta Izumi Atsuko Nagaoka Mizuki Hino Risa Shishido Makoto Sainouchi Hiroyasu Akatsu Yoshio Hashizume Akiyoshi Kakita Hirooki Yabe 《International journal of molecular sciences》2021,22(15)
Phosphoinositides (PIs) play important roles in the structure and function of the brain. Associations between PIs and the pathophysiology of schizophrenia have been studied. However, the significance of the PI metabolic pathway in the pathology of schizophrenia is unknown. We examined the expression of PI signaling-associated proteins in the postmortem brain of schizophrenia patients. Protein expression levels of phosphatidylinositol 4-phosphate 5-kinase type-1 gamma (PIP5K1C), phosphatidylinositol 4-kinase alpha (PIK4CA, also known as PIK4A), phosphatase and tensin homolog deleted from chromosome 10 (PTEN), protein kinase B (Akt), and glycogen synthase kinase 3β (GSK3β) were measured using enzyme-linked immunosorbent assays and multiplex fluorescent bead-based immunoassays of the prefrontal cortex (PFC) of postmortem samples from 23 schizophrenia patients and 47 normal controls. We also examined the association between PIK4CA expression and its genetic variants in the same brain samples. PIK4CA expression was lower, whereas Akt expression was higher, in the PFC of schizophrenia patients than in that of controls; PIP5K1C, PTEN, and GSK3β expression was not different. No single-nucleotide polymorphism significantly affected protein expression. We identified molecules involved in the pathology of schizophrenia via this lipid metabolic pathway. These results suggest that PIK4CA is involved in the mechanism underlying the pathogenesis of schizophrenia and is a potential novel therapeutic target. 相似文献
9.
Kohei Okita Ryuta Narumi Takashi Azuma Shu Takagi Yoichiro Matumoto 《Computational Mechanics》2014,54(4):1023-1033
High-intensity focused ultrasound (HIFU) has been used clinically and is under clinical trials to treat various diseases. An advanced HIFU system employs ultrasound techniques for guidance during HIFU treatment instead of magnetic resonance imaging in current HIFU systems. A HIFU beam imaging for monitoring the HIFU beam and a localized motion imaging for treatment validation of tissue are introduced briefly as the real-time ultrasound monitoring techniques. Numerical simulations have a great impact on the development of real-time ultrasound monitoring as well as the improvement of the safety and efficacy of treatment in advanced HIFU systems. A HIFU simulator was developed to reproduce ultrasound propagation through the body in consideration of the elasticity of tissue, and was validated by comparison with in vitro experiments in which the ultrasound emitted from the phased-array transducer propagates through the acrylic plate acting as a bone phantom. As the result, the defocus and distortion of the ultrasound propagating through the acrylic plate in the simulation quantitatively agree with that in the experimental results. Therefore, the HIFU simulator accurately reproduces the ultrasound propagation through the medium whose shape and physical properties are well known. In addition, it is experimentally confirmed that simulation-assisted focus control of the phased-array transducer enables efficient assignment of the focus to the target. Simulation-assisted focus control can contribute to design of transducers and treatment planning. 相似文献
10.
An ultrasonic linear motor using ridge-mode traveling waves 总被引:1,自引:0,他引:1
Tominaga M Kaminaga R Friend JR Nakamura K Ueha S 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》2005,52(10):1735-1742
A new type of ultrasonic linear motor is presented using traveling waves excited along a ridge atop a substrate. The ridge cross section was designed to permit only the fundamental mode to be excited during operation of the motor, with a Langevin transducer used as the source of vibration in this study. The ridge waveguide was first made of lossy media to avoid reflecting vibration energy back toward the vibration source, forming a traveling wave. A 5-mm-wide, 15-mm-tall rectangular acrylic ridge was used to move a slider placed upon it toward the vibration source, in opposition to the direction of the traveling wave transmitted along the waveguide ridge. Using a low-loss 3 x 6-mm aluminum rectangular ridge combined with a damper clamped onto the far end of the waveguide, similar results were obtained. To obtain bidirectional operation, the damper was replaced with a second Langevin transducer, giving a pair of transducers located perpendicularly to the ends of the ridge and driven with an appropriate phase difference. The moving direction of the slider was reversed by shifting this phase difference by about 180 degrees. With this simple configuration, it may soon be possible to fabricate a linear micromotor system on a silicon substrate or other semiconductor wafer adjacent to other electronic and optoelectronic devices. 相似文献