首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   1篇
化学工业   4篇
机械仪表   2篇
轻工业   1篇
无线电   1篇
一般工业技术   4篇
冶金工业   10篇
原子能技术   10篇
  2021年   1篇
  2020年   2篇
  2019年   1篇
  2017年   1篇
  2016年   2篇
  2014年   1篇
  2013年   6篇
  2009年   1篇
  2008年   3篇
  2007年   1篇
  2002年   1篇
  1999年   2篇
  1998年   2篇
  1997年   3篇
  1996年   2篇
  1994年   2篇
  1993年   1篇
排序方式: 共有32条查询结果,搜索用时 0 毫秒
1.
Even a zero-power reactor core containing highly enriched uranium has a weak neutron source inherent in uranium 235, and consequently, a neutron counter placed closely to the core without external neutron source registers a certain counting rate. The study of the counting is very important for zero-power reactor physics experiments with a high precision. In this experimental study, first, at a shutdown state of the UTR-Kinki reactor without start-up neutron source, a pulse height distribution of output signals from a neutron proportional counter was measured to confirm that these signals resulted from neutron detections. At several subcritical states of the UTR, then, the Feynman-α analysis was carried out to confirm that the neutrons detected by the counter must be fission neutrons multiplied by fission chain reactions. The correlation amplitude measured in the Feynman-α analysis was much higher than that measured in a previous drive by start-up source. Further, it was also confirmed that the subcriticality dependence of neutron counting rate followed the source multiplication formula. This feature indicated that the one-point model was very successful in the subcritical range including the shutdown state.  相似文献   
2.
Surgical resection, transcatheter arterial embolization (TAE) and percutaneous ethanol injection therapy (PEIT) are effective for hepatocellular carcinoma (HCC), but the recurrence rate is high. We have devised a new therapy of transarterial immuno-embolization (TIE) with OK-432, fibrinogen and thrombin, and 2 cases are reported. Case 1: A 78-year-old Japanese male with HCC (diameter, 4 cm in subsegment 5) received TIE. The tumor size was markedly decreased, and the patient survived for more than 3 years without recurrence. Case 2: A 61-year-old Japanese male with HCC (diameter, 4.5 cm in segment 5) received hepatic subsegmentectomy following TIE. Histological examination of resected specimens following TIE showed massive infiltration of mononuclear cells in the main tumor. Tumor recurrence had developed three times thereafter, but was effectively treated by TIE. TIE may be an effective therapy for HCC.  相似文献   
3.
Large negative reactivity of a subcritical system driven by a pulsed 14 MeV neutron source has been measured in the Kyoto University Critical Assembly. The subcriticality of the accelerator-driven system (ADS) ranged in effective multiplication factor roughly from 0.98 to 0.92, which corresponded to an operational range of an actual ADS proposed by Japan Atomic Energy Agency. As the measurement technique, pulsed neutron method, power spectral analysis for pulsed neutron source, accelerator-beam trip method were employed. From neutron count decay data obtained by the pulsed neutron experiment, not only the prompt-neutron decay constant of fundamental mode but also a higher spatial mode could be derived. The subcriticality was also determined from the fundamental decay constant. The measured cross-power spectral density consisted of a familiar correlated reactor-noise component and many uncorrelated delta-function-like peaks at the integral multiple of pulse repetition frequency. The fundamental prompt-neutron decay constant, i.e., the subcriticality determined from the latter uncorrelated peaks was consistent with that obtained by the above pulsed neutron experiment. However, the magnitude of the former correlated component was reduced with an increase in the subcriticality and eventually this component became almost white at deeply subcritical state ranging in the multiplication factor under 0.95. Consequently, the determination of the decay constant from the correlated component was impossible under such a subcritical state. As data analysis method for the beam trip experiment, both the conventional integral count method and the least-squares inverse kinetics method (LSIKM) were employed. The LSIKM analysis led to the consistent subcriticality with that obtained by the pulsed neutron experiment, while the integral count method significantly underestimated the subcriticality. This underestimation originated from a residual background count, which was maintained after the beam trip. The LSIKM was mostly not influenced by such a slight count rate.  相似文献   
4.
Feynman-α method is used as the representative method in reactor noise analysis for the criticality monitoring. Feynman-α analysis needs a large amount of measurement time in its original process, though many researchers use the bunching method and its derived methods for the experimental data processing to shorten the measurement time. However, the detailed characteristics and the application limit of the bunching method have not been researched and discussed enough. This paper shows a possibility that the Bunching method is a method to reduce the probability fluctuation with the Y value only in the appearance. Moreover, the criteria for determining that the Y value is not an accidental product are also provided in this paper.  相似文献   
5.
Making the angle of a hair clipper blade edge acute improves its cutting ability but causes the edge to be susceptible to wear, resulting in decreased cutting service life. An enhancement of blade edge hardness of hair clippers by various surface modifications has been studied to increase their wear resistance. Ion nitriding method formed a thick nitrided layer on the mother material surface. PVD and CVD methods formed a fine and thin hard coating at relatively low temperatures. In this study, surface modification by ion plating and plasma CVD methods was carried out to improve the cutting edge qualities of 45° angle blades, material which is used is hardened SUS420J2Mo. The effectiveness was verified by cutting performance lifetime test using artificial hair. It enhanced the cutting performance lifetime of clipper blades more than four times.  相似文献   
6.
AIM: To investigate the prevalence and amount of polyploidy in fine needle aspiration specimens of the liver, urinary cytospin preparations, and cytospin preparations from pleural and peritoneal fluid. METHODS: Cells from 44 liver smears, 48 urine specimens, and 46 pleural and peritoneal aspirations were examined. After Feulgen restaining the DNA content of 100 randomly selected nuclei was determined using a TAS-plus image analysis system, combined with an automated microscope. RESULTS: Polyploidy was observed up to 16c in the liver, and up to 8c in urothelium and mesothelium. Sixty eight per cent of the liver aspirates contained polyploid nuclei. The rate in urothelium was 20.8% and in mesothelium 6.5%. CONCLUSIONS: Polyploidy in the liver may be interpreted as being associated with tissue differentiation, but the findings in urothelium and mesothelium remain of unknown importance.  相似文献   
7.
Advances in perinatal and neonatal health care over the past few decades have resulted in a substantial reduction in perinatal mortality. Some of this improvement has been attributed to antepartum fetal surveillance techniques. The primary objective of antepartum fetal surveillance techniques is to avoid fetal deaths. An ideal secondary objective is to avoid neonatal complications related to intrauterine asphyxia. In this article, some of the difficulties in evaluating existing antepartum fetal surveillance techniques are highlighted. Some of the epidemiological methods for evaluating a screening test are reviewed and their importance discussed with reference to fetal testing procedures. Lastly, the possibility of considering indication-specific fetal testing to improve perinatal morbidity is examined.  相似文献   
8.
Anomalous continuation of the inferior vena cava with an azygous vein is a rare vacular anomaly. The enlarged venous system may simulate adenopathies or mediastinal and retroperitoneal masses on the radiographs. We describe the case of a patient with lung cancer - a pathological condition which may cause adenopathies at these sites - and a dilated azygous-hemiazygous system resulting from failure of formation of the hepatic segment of the inferior vena cava.  相似文献   
9.
ABSTRACT

For a subcritical reactor system driven by a periodically pulsed spallation neutron source in Kyoto University Critical Assembly (KUCA), the Feynman-α and the Rossi-α neutron correlation analyses were carried out to determine the prompt-neutron decay constant and quantitatively to confirm a non-Poisson characteristics of the neutron source. In these correlation analyses, a non-negligible contribution of delayed neutrons and a non-Poisson character of the source were considered, and each pulse was assumed to be a delta function. When a neutron counter was placed closely to the reactor core, the prompt-neutron decay constant determined from the present Feynman-α analysis well agreed with that done from a previous analysis for the same subcritical system driven by an inherent neutron source. However, the decay constant determined from the present Rossi-α analysis was in poor agreement with that done from the above previous analysis. This disagreement originated from an inevitable excitation of a higher mode. In the Rossi-α counting probability distribution, the excitation deformed a sharp cusp arising from the delta function to a smooth convex shape. When the data around the convex top were masked for least-squares fitting of the present Rossi-α formula, the disagreement could be successfully resolved. Compared with the previous Feynman-α and Rossi-α analyses under the Poisson inherent source, the non-Poisson spallation source definitely enhanced the respective prompt-neutron correlation amplitudes. The enhancement rate increased with an increase in subcriticality. Moreover, the Degweker’s factor (m 2-m 1 2)/m 1 2 of 0.067 ± 0.011, which indicated a non-Poisson character of the present spallation source, could be determined from the present correlation analysis and the non-zero value of the factor convinced us that the present source had a different statistical distribution from the Poisson.  相似文献   
10.
A dual-cathode arc plasma source was combined with a computer-controlled bias amplifier to synchronize substrate bias with the pulsed production of plasma. In this way, bias can be applied in a material-selective way. The principle has been applied to the synthesis of metal-doped diamondlike carbon films, where the bias was applied and adjusted when the carbon plasma was condensing and the substrate was at ground when the metal was incorporated. In doing so, excessive sputtering by energetic metal ions can be avoided while the sp(3)sp(2) ratio can be adjusted. It is shown that the resistivity of the film can be tuned by this species-selective bias; Raman spectroscopy was used to confirm expected changes of the amorphous ta-C:Mo films. The species-selective bias principle could be extended to multiple material plasma sources and complex materials.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号