首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   0篇
化学工业   2篇
建筑科学   5篇
轻工业   2篇
一般工业技术   1篇
冶金工业   5篇
自动化技术   1篇
  2016年   1篇
  2014年   1篇
  2013年   2篇
  2011年   1篇
  2010年   1篇
  2005年   1篇
  2004年   1篇
  2001年   2篇
  1998年   3篇
  1997年   1篇
  1995年   1篇
  1977年   1篇
排序方式: 共有16条查询结果,搜索用时 15 毫秒
1.
2.
Scots pine (Pinus sylvestris L.) wood was surface densified in its radial direction in an open press with one heated plate to obtain a higher density on the wood surface whilst retaining the overall thickness of the sample. This study investigated the effect of temperature (100, 150 and 200 °C) and press closing speed (5, 10 and 30 mm/min, giving closing times of 60, 30 and 10 s, respectively) on the micromorphology of the cell-wall, as well as changes occurring during set-recovery of the densified wood. The micromorphology was analysed using scanning electron microscopy (SEM) combined with a sample preparation technique based on ultraviolet-excimer laser ablation. Furthermore, the density profiles of the samples were measured. Low press temperature (100 °C) and short closing time (10 s) resulted in more deformation through the whole thickness, whilst increasing the temperature (150 and 200 °C) and prolonging the closing time (30 and 60 s) enabled more targeted deformation closer to the heated plate. The deformation occurred in the earlywood regions as curling and twisting of the radial cell-walls, however, no apparent cell-wall disruption or internal fracture was observed, even at low temperatures and fast press closing speed, nor after soaking and drying of the samples. In the SEM-analysis after soaking and drying, it was noticed that the cells did not completely recover their original form. Thus, part of the deformation was considered permanent perhaps due to viscoelastic flow and plastic deformation of the cell-wall components.  相似文献   
3.
Several studies have found that indoor air quality (IAQ) in schools is often poor and may affect the health of the pupils. Building ventilation is a means to reduce pollutants indoors, but different designs should be evaluated for their effectiveness in different environments. In a field experiment performed at four classrooms in one school building, air was supplied either in the mixing or in the displacement mode, and we collected information on exposures, pupils' perception of IAQ and climate, and health symptoms and performed clinical examinations. The room temperature, relative humidity, concentration of CO?, and cat allergen were measured at the breathing height and were similar during each ventilation mode. The children perceived IAQ were similar in the two ventilation regimes, and there were few differences in symptom reports or clinical parameters. However, the pupils reported more eye symptoms during displacement ventilation. PRACTICAL IMPLICATIONS: Both mixing and displacement ventilation may be appropriate in school classrooms as long as the overall design, ventilation rates, and maintenance of systems are satisfactory.  相似文献   
4.
Electroconvulsive therapy (ECT) was given to 16 non-depressed, non-demented patients with advanced Parkinson's disease (PD). In all the patients an antiparkinsonian effect was seen, lasting for 18 months in one patient, 3-5 months in seven patients, and a few days to four weeks in eight patients. After ECT the levels of homovanillic acid and neuropeptide Y in cerebrospinal fluid (CSF) were significantly increased. The eight patients with long lasting motor improvement after ECT had significantly lower CSF-3-methoxy-4-hydroxyphenylglycol compared to the group with short lasting improvement. Five patients developed transitory mental confusion after ECT. In these patients, and in no others, a high albumin-ratio was found already before ECT was given - an indication of blood CSF barrier damage. Our results suggest that ECT is valuable in patients with drug refractory PD or PD with intolerance to antiparkinsonian drugs.  相似文献   
5.
The purified isopropylmalate synthase of Alcaligenes eutrophus H 16 reacted with the following alpha-keto acids and acyl-coenzyme A derivatives (in the sequence of decreasing affinities): alpha-ketoisovalerate, alpha-keto-n-valerate, alpha-ketobutyrate and pyruvate; acetyl-CoA, propionyl-CoA, butyryl-CoA, malonyl-CoA, valeryl-CoA, and crotonyl0CoA. alpha-Ketoisocaproate, however, is a strong inhibitor of the enzyme. All reactions catalyzed by isopropylmalate synthase were inhibited to the same extent by the endproduct L-leucine. The substrate saturation curves of alpha-ketoisovalerate or other alpha-keto acids and of acetyl-coenzyme A or other acyl-CoA derivatives had intermediary plateau regions; the Hill coefficient alternated between nH-values higher and lower than 1.0, indicating changes from positive to negative and from negative to positive cooperativity for the substrates. The products, isopropylmalate and free coenzyme A, showed competitive inhibition patterns against both substrates (alpha-ketoisovalerate and acetyl-CoA). Free coenzyme A (1 micronM) inactivated the enzyme irreversibly. The 3'-phosphate of coenzyme A and the free carboxyl group of alpha-ketoisovalerate were involved in optimal binding of these substrates, but 3'-dephospho-acetyl-coenzyme A and the methylester of alpha-keto-isovalerate were also converted by this enzyme. A CH3--CH2-grouping of the alpha-keto acids seemed to be necessary for binding this substrate.  相似文献   
6.
7.
Wetting dynamics on machined wood surfaces is of great interest for the adhesive bonding technology of wood. In this work, the change of apparent contact angles with time of phenolresorcinol-formaldehyde (PRF), polyvinyl-acetate (PVAc), and a series of probe liquids on sawed, planed, sanded, and razor-blade-cut wood surfaces of Southern pine was studied by the sessile drop method using a CCD camera technique. The results indicate that the fastest wetting of the probe liquids occurs on the sanded surfaces because of higher surface roughness and the resulting increase in capillary forces as compared with the sawed, planed and razor blade cut surfaces. The fastest wetting of the PRF and PVAc resins occurred on the comparably smooth planed and razor-blade-cut wood surfaces. A smoother wood surface seems to provide better wetting and penetration properties for high-viscosity liquids such as adhesives, which probably can be attributed to less entrapment of air between the resin and the wood structure.  相似文献   
8.
9.
Abstract Acoustic rhinometry and hygienic measurements of indoor air pollutants were applied in a field study on nasal congestion among 27 subjects working in two primary schools. One school had natural ventilation only and a low air exchange rate (0.6 ac/h); the other had balanced mechanical ventilation and a high air exchange rate (5.2 ac/h). The minimal cross-sectional area and volume of the nasal cavity were estimated with acoustic rhinometry. The degree of swelling of the nasal mucosa was measured as the increase of the cross-sectional area after standardized application of nasal spray containing a decongestive adrenergic substance. Reports on weekly symptoms of nasal congestion were similar (33%) in both schools. A significantly increased decongestive effect was noticed for the minimal cross-sectional area (MCA2) among personnel in the school with a low air exchange rate. The difference between the schools in decongestive effect on MCA2 was 23%, corresponding to a 3% increase of MCA2 for a difference in personal outdoor airflow of one litre. Indoor concentration of volatile organic compounds (VOC), respirable dust, bacteria, moulds and VOCs of possible microbial origin (MVOC) were 2–8 times higher in the naturally ventilated school. In conclusion, inadequate outdoor air supply in schools may lead to raised levels of indoor air pollutants, causing a sub-clinical swelling of the nasal mucosa. Our results indicate that acoustic rhinometry could be applied in field studies, and that objective measurement of nasal decongestion might be a more sensitive measure of biological effects of indoor air pollution than symptom reporting.  相似文献   
10.
It has been suggested that certain building factors can be associated with specific exposures, such as dampness, chemical emissions and dust. The aim of the study was to examine the relationships between some selected building factors, on the one hand, and signs of inflammation or obstruction in the upper airways on the other. Acoustic rhinometry and nasal lavage were used in a field study among 234 school personnel in 12 randomly selected schools (participation rate 84%). Eosinophil cationic protein (ECP), lysozyme, albumin and myeloperoxidase (MPO) were analyzed in the lavage fluid. Building related factors selected for the study were: roof inclination, fundament, building construction, signs of water damage, floor material, building age, ceiling height, bookcases and plants in the classroom. Control was made for potential confounders. The results indicate a pattern of nasal responses: less patent noses and an inflammatory biomarker response could be related to flat roof and a concrete slab fundament, factors that are known risk factors for water leakage, building dampness and possibly microbial growth. A reduced nasal patency without an inflammatory biomarker response was related to factors associated with plasticizers and dust. Positive effects were observed for plants in the classroom and in older buildings.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号