首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   47篇
  免费   0篇
化学工业   6篇
金属工艺   1篇
机械仪表   3篇
轻工业   8篇
无线电   1篇
一般工业技术   13篇
冶金工业   15篇
  2021年   2篇
  2020年   1篇
  2019年   1篇
  2017年   1篇
  2016年   1篇
  2013年   4篇
  2012年   4篇
  2011年   4篇
  2009年   3篇
  2008年   4篇
  2007年   3篇
  2005年   2篇
  2002年   1篇
  2000年   2篇
  1999年   1篇
  1998年   6篇
  1997年   4篇
  1996年   1篇
  1995年   1篇
  1980年   1篇
排序方式: 共有47条查询结果,搜索用时 18 毫秒
1.
2.
Investigation into the corrosion inhibition of low carbon steel in 0.1-M HCl solution by 1-ethyl-1-methylpyrrolidinium (EMTFB) and the effect of KI addition on the inhibition efficiency was carried out using potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy and surface analysis (scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDAX)) techniques. Results show that EMTFB suppresses low carbon steel dissolution in the corrosive environment. Inhibition efficiency increased with the increase in EMTFB concentration. Addition of iodide ions to EMTFB raises inhibition efficiency from 75 to 98%. PDP results indicate that EMTFB affects majorly anodic reactions while EMTFB + KI act as cathodic-type inhibitor. The adsorption of EMTFB onto low carbon steel surface is by physical adsorption mechanism and follows Langmuir adsorption isotherm model. SEM and EDAX results confirm the adsorption of EMTFB alone and in combination with KI onto the steel surface.  相似文献   
3.
4.
We introduce an adaptive variable bias current control scheme to minimize the energy consumption of magnetic bearings without altering the dynamic performance. We developed analytical expressions for the optimum bias current settings for both differential and unidirectional modes of operation as a function of the orbit size and the desired bearing stiffness. The orbit size is measured in situ by a recursive Fourier coefficient calculation. The analytical results are presented in normalized variables, and hence can be applied to any size and type of magnetic bearing. Both zero and nonzero static load cases are considered. We show analytically that, under variable bias current operation, the differential mode provides better energy efficiency and stiffness capacity than the unidirectional mode. We present the energy consumption data obtained experimentally on a flexible rotor magnetic bearing rig. The data show that, with the proposed variable bias current approach, a significant energy saving can be obtained without deterioration of dynamic performance  相似文献   
5.
OBJECTIVE: To identify risk factors for polymicrobial bloodstream infections (BSIs) in neonatal intensive care unit (NICU) patients during an outbreak of BSIs. DESIGN: During an outbreak of BSIs, we conducted a retrospective cohort study, assessed NICU infection control practices and patient exposure to NICU healthcare workers (HCWs), and obtained cultures of the environment and HCW hands. PATIENTS: During the period May 3 to 7, 1996, 5 infants contracted BSIs caused by both Enterobacter cloacae and Pseudomonas aeruginosa, and one infant contracted a BSI caused by E cloacae only. For each pathogen, all isolates were identical on DNA typing. RESULTS: Infants exposed to the following were more likely than nonexposed infants to have BSI: umbilical venous catheters (6/14 vs 0/7, P = .05), total parenteral nutrition given simultaneously with a dextrose/electrolyte solution (6/12 vs 0/9, P = .02), or one HCW (5/7 vs 1/13, P = .007). Neither environmental nor HCW hand cultures yielded the outbreak pathogens. Quality control cultures of intravenous solution bags were negative. CONCLUSIONS: We speculate that a dextrose multidose vial became contaminated during manipulation or needle puncture and that successive use of this contaminated vial for multiple patients may have been responsible for BSIs. Aseptic techniques must be employed when multidose vial medications are used. Single-dose vials should be used for parenteral additives whenever possible to reduce the risk of extrinsic contamination and subsequent transmission of nosocomial pathogens.  相似文献   
6.
Necip Atar 《Desalination》2009,249(1):109-13
In this study, batch experiments were carried out for the sorption of basic blue 41 (BB 41), and acid blue 225 (AB 225) onto boron waste (BW) from boron enrichment plant. The operating variables studied are the initial dye concentration, contact time, solution pH, and adsorbent dosage. The experimental equilibrium data were analyzed by using various adsorption isotherm models and the results have shown that the adsorption behavior of AB 225 and BB 41 could be described well reasonably by Langmuir and Temkin isotherms, respectively. Kinetics studies indicated that the adsorption of both dyes follow pseudo-second-order kinetics. The sorption of basic dye increased at high pH values, whereas the opposite was true for acidic dye. The results indicate that BW could be employed as low-cost alternatives to the commercially available adsorbents in wastewater treatment for the removal of acid and basic dyes.  相似文献   
7.
The carbohydrate and aromatic amino acid metabolism of several species related to the human colon was investigated into more detail. Therefore, in vitro fermentations were performed, with different carbohydrate sources, during which several aromatic amino acids were added to the fermentation medium. Shifts in end-product formation in response to the available nutrients were observed for all strains tested. The major part of amino acid degradation occurred after depletion of the carbohydrates. Moreover, it was shown that Bifidobacterium strains are capable of degrading aromatic amino acids in the absence of carbohydrates. The excretion of certain intermediates of the aromatic amino acid metabolism was observed for a strain of Clostridium clostridioforme, after which they were metabolized again during a later stage of fermentation. This implies that cross-feeding on degradation products of aromatic amino acids, albeit within the same species, can occur in the human colon.  相似文献   
8.
In the present study, 17 wt % TiN reinforced α-β SiAlON composites were sintered at low temperature by susceptor-assisted microwave heating. The effect of TiN addition on dielectrical properties of starting powders, as well as the influence of sintering temperature on phase evolution, microstructure development and mechanical properties of α/β-SiAlON-TiN composites were investigated. The obtained results showed that TiN addition increased the microwave absorbing properties which is reflected in the peak sintering temperature. Thus, the α:β ratio decreased and mechanical properties were improved, especially the fracture toughness of the composites. Furthermore, an estimate of energy consumption during microwave assisted sintering at the laboratory scale is presented. As a result, the highest values for relative density (97.1%), Vickers hardness (13.35 ± 0.47 GPa), and fracture toughness (7.52 ± 0.54 MPa m1/2) were obtained by microwave sintering for 30 min at 1300 °C.  相似文献   
9.
PurposeTo compare the topographic and biomechanical properties of corneas in eyes of patients with ichthyosis vulgaris (IV) and eyes of healthy individuals.MethodsThirty healthy individuals (control group) and 30 patients with IV (study group) were enrolled in this prospective study. Topographic measurements, including keratometry values, irregularity, and surface asymmetry index in the right eye of each participant were obtained using Scheimpflug camera with a Placido disc topographer (Sirius). Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldman-related intraocular pressure (IOPg) were measured using the Reichert Ocular Response Analyzer (ORA). Central corneal thickness (CCT) was also measured with ultrasonic pachymetry and the Sirius corneal topography system.ResultsTopographic parameters were not significantly different between both groups (p > 0.05). Although mean CH was not significantly different between the groups, the CRF was significantly lower in patients with IV (p = 0.249 and p = 0.005, respectively). The CCT was significantly lower in patients with IV compared to healthy controls (p < 0.001). The IOPg and IOPcc were significantly lower in the patients with ichthyosis than in healthy controls (p = 0.001 and p = 0.004, respectively).ConclusionsThe study demonstrated that while the eyes of patients with IV had corneal topographic findings and corneal hysteresis similar to those of healthy controls, some of corneal biomechanical properties such CRF and CCT and IOP values such as IOPg and IOPcc were significantly lower in patients with IV. These results should be taken into account when planning a corneal refractive surgery and glaucoma screening for patients with IV.  相似文献   
10.
OBJECTIVE: To evaluate the effects of high-frequency jet ventilation (HFJV) applied to both lungs on hemodynamic parameters, oxygenation, and operating conditions during bilateral videothoracoscopic sympathectomy. DESIGN: A prospective, unblinded study. SETTING: An ambulatory surgical unit at a university medical center. PARTICIPANTS: 30 patients (11 men, 19 women), ASA status 1. INTERVENTION: Bilateral videothoracoscopic sympathectomies were performed using total intravenous anesthesia with propofol, alfentanil, and atracurium, and the patients were ventilated with an oxygen-air mixture using HFJV delivered to both lungs with a Hi-Lo Jet tracheal tube (Mallinckrodt). MEASUREMENTS AND MAIN RESULTS: Mean total anesthesia time was 55 +/- 13 minutes. Hemodynamic parameters remained stable during surgery, although ablation of the sympathetic ganglia induced three incidences of bradycardia (10% of the patients), which were responsive to atropine. Four patients developed oxygen desaturation (Sa O2 < 90%) after the creation of the pneumothorax. Surgical conditions were considered excellent by the surgeons. Concerning postoperative complications, a temporary Horner's syndrome was observed in one patient. Another patient had a mild residual pneumothorax on the first postoperative day that resolved without insertion of a chest tube. CONCLUSIONS: It was concluded that HFJV applied to both lungs is an easy and safe anesthetic technique that provides excellent surgical conditions and causes a minor incidence of morbidity.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号