首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   29篇
  免费   0篇
化学工业   3篇
机械仪表   4篇
建筑科学   4篇
轻工业   5篇
水利工程   1篇
无线电   4篇
一般工业技术   2篇
冶金工业   4篇
自动化技术   2篇
  2023年   1篇
  2018年   1篇
  2017年   1篇
  2011年   3篇
  2010年   2篇
  2009年   2篇
  2006年   1篇
  2005年   2篇
  1998年   1篇
  1996年   1篇
  1995年   1篇
  1994年   2篇
  1992年   1篇
  1989年   1篇
  1986年   2篇
  1985年   1篇
  1983年   2篇
  1981年   1篇
  1980年   2篇
  1979年   1篇
排序方式: 共有29条查询结果,搜索用时 15 毫秒
1.
2.
Algorithms for calculating the emitter hole and electron currents in the case of an n+n? epitaxial emitter have been published by Yu [2] and Rofail et al. [3]. Both algorithms are restricted to a small ratio of hole to electron current whereas Yu's algorithm is further restricted by the assumption of a constant electric field in the epilayer.In the present paper an algorithm is presented in which both restrictions have been removed and which is valid from low through high injection. The assumption of quasineutrality in the epilayer, which is used in the present algorithm, is veryfied using Adlers criterium [4]. Calculation results are presented for a structure treated by Poorter [1] and a comparison is made with his results.  相似文献   
3.
4.
5.
Contaminants from the soil surrounding drinking water distribution systems are thought to not enter the drinking water when sufficient internal pressure is maintained. Pressure transients may cause short intervals of negative pressure, and the soil near drinking water pipes often contains fecal material due to the proximity of sewage lines, so that a pressure event may cause intrusion of pathogens. This paper presents a risk model for predicting intrusion and dilution of viruses and their transport to consumers. Random entry and dilution of virus was simulated by embedding the hydraulic model into a Monte Carlo simulation. Special attention was given to adjusting for the coincidence of virus presence and use of tap water, as independently occurring short-term events within the longer interval that the virus is predicted to travel in any branch of the distribution system. The probability that a consumer drinks water contaminated with virus is small, but when this happens the virus concentration tends to be high and the risk of infection may be considerable. The spatial distribution of infection risk is highly heterogeneous. The presence of a chlorine residual reduces the infection risk.  相似文献   
6.
Folding nanopatterned flat sheets into complex 3D structures enables the fabrication of meta-biomaterials that combine a rationally designed 3D architecture with nanoscale surface features. Self-folding is an attractive approach for realizing such materials. However, self-folded lattices are generally too compliant as there is an inherent competition between ease-of-folding requirements and final load-bearing characteristics. Inspired by sheet metal forming, an alternative route is proposed for the fabrication of origamilattices. This ‘automated-folding’ approach allows for the introduction of sharp folds into thick metal sheets, thereby enhancing their stiffness. The first time realization of automatically folded origami lattices with bone-mimicking mechanical properties is demonstrated. The proposed approach is highly scalable given that the unit cells making up the meta-biomaterial can be arbitrarily large in number and small in dimensions. To demonstrate the scalability and versatility of the proposed approach, it is fabricated origamilattices with > 100 unit cells, lattices with unit cells as small as 1.25 mm, and auxetic lattices. The nanopatterned the surface of the sheets prior to folding. Protected by a thin coating layer, these nanoscale features remained intact during the folding process. It is found that the nanopatterned folded specimens exhibits significantly increased mineralization as compared to their non-patterned counterparts.  相似文献   
7.
An attempt will be made to put together all information on I2L base current available from literature. The aim is to get explicit relations for all base current components at low, medium and high injection. This requires knowledge of excess concentration patterns and stored excess charge as well as of the associated time constants. As a final result the upward current amplification βu and the upward time constant τu are obtained. In the latter no depletion charges have been taken along and a quasi-static condition is assumed. Lateral base current effects have not been taken into account.  相似文献   
8.
Faecally impacted surface waters used for drinking water production may encompass risk for norovirus infections. To be able to assess a possible health risk, noroviruses should be quantified and fluctuations identified. In 2001, norovirus concentrations in the river Meuse displayed a seasonal distribution with high peaks during wintertime as determined by RT-PCR on serially diluted RNA. An intensified day-by-day sampling scheme in the winter of 2002/2003 revealed that the winter peak consisted of several peaks of varying duration and magnitude, possibly due to contamination events in the catchment. The highest estimated concentration was 1700 PCR-detectable units per litre (95% CI 250-8000), which if coinciding with failing treatment could lead to significant numbers in drinking water. Adaptive dynamic filtering was shown to adequately predict subsequent sample concentrations. If valid, such analyses could prove to be useful as early warning systems in risk management of water sources.  相似文献   
9.
10.
Even at very low concentrations human pathogenic viruses may result in infection and possibly subsequent disease. Ideally, viruses are quantified by use of cell culture assays to determine their infectivity. Plaque assays are common tools for enumeration of viruses in inocula and this process is straightforward when a plaque results from the offspring of a single infectious virus particle. In the course of a study on the usefulness of sewage monitoring for surveillance of polio-virus transmission, sewage samples containing a mixture of two live polio vaccine strains (type 1 and type 3) were analyzed. The total poliovirus concentration in plaque forming units (pfu) was estimated by means of a monolayer plaque assay on L20B cells. Subsequent typing of virus directly by neutralisation of virus from excised plaques revealed the occurrence of plaques containing both type 1 and type 3 virus. This means that there must be plaques that originate from more than one initial infectious virus particle. As a consequence, the estimated virus concentration is incorrect. We present statistical methods that utilize these mixed plaque counts to estimate the concentrations of either virus type in our sewage samples. We can also calculate a correction factor for the error in virus concentration, which would result from equating a pfu to a single infectious particle. Since many quantitative methods in microbiology are based on colony counts, we conclude that such counts should be interpreted with caution, especially when data are used in quantitative microbial risk assessment to estimate the public health impact.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏