Within the European Community, the interest in energy generation from biomass and waste is increasing. A brief overview is given of several thermal conversion technologies, of biomass production and waste availability in the Netherlands. Based on this, the possibilities for energy generation from biomass and waste in the Netherlands are evaluated. 相似文献
Contents Surface charge accumulation and its decay at a GIS spacer are studied at atmospheric conditions employing a two step-calibration method. The results show that the accumulation saturates within 30 minutes; the dominant mechanism of surface charge accumulation is the drift of charged particles via air, while that of the decay is surface conduction. The characteristics are similar at both polarities.
Sättigungskonzentration und Abklingverhalten der Oberflächenladung an einem mit Gleichspannung beanspruchten Abstandshalter unter atmosphärischen Bedingungen
Übersicht Die Konzentration und das Abklingen von Oberflächenladungen an einem GIS Abstandshalter wurden unter atmosphärischen Bedingungen mit Hilfe eines zweistufigen Kalibrierungsverfahrens untersucht. Die Ergebnisse zeigen eine Sättigung der Ladungskonzentration innerhalb von 30 Minuten. Als Hauptursache der Ladungskonzentration ist die Drift geladener Teilchen in Luft anzusehen, während das Abklingen auf die Oberflächenleitung zurückzuführen ist. Ähnliche Charakteristiken ergeben sich mit beiden Polaritäten.
The birefringences of injection molded plates and the birefringence during steady, isothermal shear flow were compared for some amorphous polymers. The materials studied were a polystyrene, a “toughened” polystyrene and an acrylonitrile-butadiene-styrene copolymer. The birefringence of the plates, notably the maximum value for the average over the thickness was found to be related to the shear stress at the cavity wall that had occurred during the mold filling process. This relationship was independent of temperature. To a good approximation, it was also the same as the relationship between the flow birefringence and the shear stress at the wall in isothermal channel flow. It thus appears that the anisotropy of injection molded objects is dominated by the shear stresses during the mold filling process regardless of the temperature and of the macroscopic rate of deformation. 相似文献
An experimental approach was performed on 20 giant rabbits to establish the possibilities and limitations of μ-CT for routine processing of nondemineralized bone tissue. Hydroxyapatite (HA) or β-tricalciumphosphate (β-TCP) bead implants or a melange of both, microchambered and solid, were implanted into a standardized and precise defect in the patellar groove. The bone-healing phase was chosen for the histology considering 1 or 2 days, and 2, 3, and 6 weeks. Normal X-ray and μ-CT were applied on all specimens; five specimens in the 6-week stage were additionally processed according to the full range of conventional nondemineralized bone processing methods. μ-CT increased the possibilities of nondemineralized histology with respect to bone morphometry and a complete sequence of sections, thus providing a complete analysis of the bone response. μ-CT was limited in differentiating bone quality, cell analyses, and mineralization stages. The investigation based on normal X-rays is limited to defining integration and excluding the fibrous and bony encapsulation of loose implants. μ-CT allows a 3D evaluation of newly formed bone which is clearly marked against the ceramic implant. It does not allow, however, for the differentiation between woven and lamellar bone, the presentation of the canalicular lacunar system, or on the cell level, revealing canaliculi or details of the mineralization process which can be documented by high-resolution microradiography. Titer dynamics of bone formation remains the domain of polychromatic sequential labeling. The complete sequence of μ-CT slices enhances the possibilities for routine histology, tremendously allowing to the focus on detail histology to topographically well-defined cuts, thus providing more precise conclusions which take into consideration the whole implant. 相似文献
There is a pressing need to assess user-dependent reproducibility of multi-fibre probabilistic tractography in order to encourage clinical implementation of these advanced and relevant approaches. The goal of this study was to evaluate both intrinsic and inter-user reproducibility of corticospinal tract estimation.
Materials and methods
Six clinical datasets including motor functional and diffusion MRI were used. Three users performed an independent tractography analysis following identical instructions. Dice indices were calculated to quantify the reproducibility of seed region, fMRI-based end region, and streamline maps.
Results
The inter-user reproducibility ranged 41–93%, 29–94%, and 50–92%, for seed regions, end regions, and streamline maps, respectively. Differences in streamline maps correlated with differences in seed and end regions. Good inter-user agreement in seed and end regions, yielded inter-user reproducibility close to the intrinsic reproducibility (92–97%) and in most cases higher than 80%.
Discussion
Uncertainties related to user-dependent decisions and the probabilistic nature of the analysis should be considered when interpreting probabilistic tractography data. The standardization of the methods used to define seed and end regions is a necessary step to improve the accuracy and robustness of multi-fiber probabilistic tractography in a clinical setting. Clinical users should choose a feasible compromise between reproducibility and analysis duration.