首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   38篇
  免费   0篇
化学工业   15篇
金属工艺   1篇
机械仪表   3篇
能源动力   2篇
一般工业技术   8篇
冶金工业   1篇
自动化技术   8篇
  2024年   1篇
  2023年   1篇
  2021年   1篇
  2020年   2篇
  2019年   4篇
  2018年   1篇
  2016年   2篇
  2015年   1篇
  2013年   8篇
  2012年   4篇
  2011年   3篇
  2009年   2篇
  2007年   1篇
  2006年   1篇
  1998年   2篇
  1997年   1篇
  1987年   1篇
  1984年   1篇
  1979年   1篇
排序方式: 共有38条查询结果,搜索用时 15 毫秒
1.
Scheduling emergency medicine residents (EMRs) is a complex task, which considers a large number of rules (often conflicting) related to various aspects such as limits on the number of consecutive work hours, number of day and night shifts that should be worked by each resident, resident staffing requirements according to seniority levels for the day and night shifts, restrictions on the number of consecutive day and night shifts assigned, vacation periods, weekend off requests, and fair distribution of responsibilities among the residents. Emergency rooms (ERs) are stressful workplaces, and in addition shift work is well-known to be more demanding than regular daytime work. For this reason, preparing schedules that suit the working rules for EMRs is especially important for reducing the negative impact on shift workers physiologically, psychologically, and socially. In this paper, we present a goal programming (GP) model that accommodates both hard and soft constraints for a monthly planning horizon. The hard constraints should be adhered to strictly, whereas the soft constraints can be violated when necessary. The relative importance values of the soft constraints have been computed by the analytical hierarchy process (AHP), which are used as coefficients of the deviations from the soft constraints in the objective function. The model has been tested in the ER of a major local university hospital. The main conclusions of the study are that problems of realistic size can be solved quickly and the generated schedules have very high qualities compared to the manually prepared schedules, which require a lot of effort and time from the chief resident who is responsible for this duty.  相似文献   
2.
Persistent calls come from within the graduate medical education community and from external sources for regulating the resident duty hours in order to meet the obligations about the quality of resident education, the well-being of residents themselves, and the quality of patient care services. The report of the Accreditation Council for Graduate Medical Education (ACGME) proposes common program requirements for resident hours. In this paper, we first develop a mixed-integer programming model for scheduling residents’ duty hours considering the on-call night, day-off, rest period, and total work-hour ACGME regulations as well as the demand coverage requirements of the residency program. Subsequently, we propose a column generation model that consists of a master problem and an auxiliary problem. The master problem finds a configuration of individual schedules that minimizes the sum of deviations from the desired service levels for the day and night periods. The formulation of this problem is possible by representing the feasible schedules using column variables, whereas the auxiliary problem finds the whole set of feasible schedules using constraint programming. The proposed approach has been tested on a series of problems using real data obtained from a hospital. The results indicate that high-quality schedules can be obtained within a few seconds.  相似文献   
3.
In this study, pyrolysis of tomato waste has been performed in fixed bed tubular reactor at 500 °C, both in absence and presence of Cu/Al2O3 catalyst. The influences of heating rate, catalyst preparation method and catalyst loading on bio-oil yields and properties were examined. According to pyrolysis experiments, the highest bio-oil yield was obtained as 30.31% with a heating rate of 100 °C/min, 5% Cu/Al2O3 catalyst loading ratio and co-precipitation method. Results showed that the catalysts have strong positive effect on bio-oil yields. Bio-oil quality obtained from fast catalytic pyrolysis was more favorable than that obtained from non-catalytic and slow catalytic pyrolysis.  相似文献   
4.
Studies on supply chain complexity mainly use the static and dynamic complexity distinction. While static complexity describes the structure of the supply chain, the number and the variety of its components and strengths of interactions between these; the dynamic complexity represents the uncertainty in the supply chain and involves the aspects of time and randomness. This distinction is also valid when classifying the drivers of supply chain complexity according to the way they are generated. Supply chain complexity drivers (e.g., number/variety of suppliers, number/variety of customers, number/variety of interactions, conflicting policies, demand amplification, differing/conflicting/non-synchronized decisions and actions, incompatible IT systems) play a significant and varying role in dealing with complexity of the different types of supply chains (e.g., food, chemical, electronics, automotive).  相似文献   
5.
The existing solution methods for the Weibull Renewal Equation suffer from a lack of sufficient accuracy due to the singularity at the origin for some parameter values of the weibull density. The proposed method of solution provides accuracy to any desired degree of precision for all parameter values particularly in the singular range. The method utilizes a cubic spline approximation of the unknown renewal function and applies the Galerkin technique of integral equation solution. Gaussian quadratures are used to evaluate integrals. The singular nature of the integrand is handled by the Gauss-Jacobi quadrature. Results are compared with those obtained by simulation.  相似文献   
6.
BACKGROUND: Hydrogen peroxide biosensors based on Poly(glycidyl methacrylate‐co‐3‐thienylmethylmethacrylate)/ Polypyrrole [Poly(GMA‐co‐MTM)/PPy] composite film were reported. Poly(GMA‐co‐MTM) including various amounts of GMA and MTM monomers was synthesized via the radical polymerization. Enzyme horseradish peroxidase (HRP) was trapped in Poly(GMA‐co‐MTM)/PPy composites during the electropolymerization reaction between pyrrole and thiophene groups of MTM monomer, and chemically bonded via the epoxy groups of GMA. Analytical parameters of the fabricated electrodes were calculated and are discussed in terms of film electroactivity and mass transfer conditions of the composite films. RESULTS: The amount of electroactive HRP was found to be 1.25, 0.34 and 0.213 µg for the working electrodes of Poly(GMA30%co‐MTM70%)/PPy/HRP, Poly(GMA85%co‐MTM15%)/PPy/HRP and Poly(GMA90%co‐MTM10%)/PPy/HRP, respectively. Optimal response of the fabricated electrodes was obtained at pH 7 and an operational potential of ? 0.35 V. It was observed that effective enzyme immobilization and electroactivity of the composite films could be changed by changing the ratios of GMA and MTM fractions of Poly(GMA‐co‐MTM) based working electrodes. CONCLUSION: The amount of electroactive enzyme increases with increasing MTM content of the final copolymer. High operational stabilities of the biosensors can be attributed to the strong covalent enzyme linkage via the epoxy groups of GMA due to preventing enzyme deterioration and loss. A more convenient microenvironment for mass transfer was provided for the electrodes by higher GMA ratios. It is observed that mass transfer is dominated by the mechanism of electron transfer to obtain effective sensitivity values. This work contributes to discussions clarifying the problems regarding the design parameters of biosensors. Copyright © 2011 Society of Chemical Industry  相似文献   
7.
8.
A novel continuous flow biosensor based on gold nanoparticles and poly(propylene-co-imidazole) was developed for the online determination of p-benzoquinone. The amperometric response was measured as a function of p-benzoquinone concentration at an applied potential of ?50 mV. The hydrogen peroxide concentration was optimized and fixed at 1 mM in samples. The mass transfer resistance of the copolymer film was minimized, and the flow cell was regenerated quickly at 1 mL/min. The resulting device provided good analytical performance based on a linear dynamic range from 5–100 µM, a short response time of 3 s, a detection limit of 3.3 µM, excellent repeatability with a relative standard deviation of 0.82%, long-term stability of 95% after four weeks, and an accuracy of 105%. The gold nanoparticles enhanced the electron transfer rate on the electrode. The apparent Michaelis-Menten constant was 4 mM, showing that the enzyme retained catalytic specificity and provided high activity for p-benzoquinone.  相似文献   
9.
Superabsorbent polymers (SAPs) constitute a special class of polymers widely used in various fields, especially in the hygiene and healthcare sectors. This study investigates the feasibility of achieving high water absorption capacity surfaces by coating powdered SAP using conventional coating methods onto textile surfaces. For this purpose, water-based coating pastes containing micronized SAP powder based on acrylamide/acrylic acid copolymer were coated onto polyester (PES)-woven fabric surfaces using a knife-over-roll coating technique. As the working parameters, the pH value of the coating paste, the coating thickness (the distance between the cloth and the knife), the drying/fixing temperature and time, the SAP concentration, and the water absorption capacity according to time were investigated. The results were evaluated by applying the coating thickness, the amount of coating material transferred to the fabric on the SAP-coated samples, water absorbing capacity, and centrifugal water retention tests. The obtained results have demonstrated that textile surfaces with high water absorption capacity (on average 200%–350%) can be achieved by coating hydrophobic fabric surfaces, such as PES, with SAP under suitable conditions.  相似文献   
10.
Objective: The purpose of this in vitro study was to evaluate the effect of thermal cycling on the micro-tensile bond strength (Mtbs) of multimode adhesive agents. Materials and methods: Eight freshly extracted caries-free human third molars were used. The flat dentin surfaces were prepared and polished with 600-grit SiC abrasive paper for standard smear layer formation. The teeth were restored using Single Bond Universal Adhesive [(total etch (G1, G2)/self etch (G3, G4)]?+?Filtek Z550 and All-Bond Universal Adhesive [(total etch (G5, G6)/self etch (G7, G8)]?+?Aelite all-purpose. The specimens in groups G1, G3, G5, and G7 were subjected to thermal cycling (1000 cycles at 5–55 °C, for a 30?s dwell time), while the specimens in other groups were not exposed to an aging procedure. The Mtbs test was determined in all procedures. Data were submitted to three-way ANOVA and post hoc tests. The significance level was set at?=?0.05. Results: Group five was highly affected by the thermal cycling following the total etch procedure, while group one was not significantly affected. Group seven was highly affected by thermal cycling, while group three was not significantly affected after the self etch procedure. Group eight exhibited a higher mean Mtbs value after the thermal cycling procedure. Conclusion: The bond strength of multimode (universal) adhesives was found to be material dependent. The total etch procedure showed a higher Mtbs value than the self etch procedure.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号