Because of heat amount is different from peripheral to central of friction welding interface, which is leaded to vary the characterizations along that interface. Current study, respectively, focused on the effect of different friction pressure on micro-structural and mechanical properties of that friction welding joint interface. Presently, these friction pressures are 110, 130, 150 and 170 MPa while kept all other conditions constant. The effects of different friction pressure on welding interface characterization were investigated by EDX, SEM, tensile, compression, impact and hardness tests. The tensile tests carried out on the standardized test piece with diameter 6 mm and 8 mm, thus, compression tests were extracted from the positions of 0°, 45° 90° with test specimen of 4 mm diameter and 6.5 mm length at weld center. Whereas, the impact test pieces were picked up in two positions, the first one is symmetrical, which it obtained to the respect of the rotation axis and the interface, on the other hand, the second one is non-symmetrical with the axis of rotation and symmetrical to the interface, for making the notch head coincide with the center of the welded joint, The obtained results showed that with reducing of friction pressure will present lack of bonding increasing from peripheral toward the welding center, which will responsible on reducing of the mechanical properties such as tensile, compression and impact strength. 相似文献
The efficiency of any electric cell or battery is very important. To keep it in mind it has been studied the columbic efficiency, voltaic efficiency and energy efficiency of a PKL (Pathor Kuchi Leaf) Quasi Voltaic Cell or Modified Voltaic Cell. It was found that the columbic efficiency data illustrated that this efficiency was lower comparing to other efficiencies may be the absence of salt bridge or separator between the electrodes. Because, our designed and fabricated PKL cell does not have any salt bridge. So that the internal resistance is lower than the traditional voltaic cell and as a result more current was found. The voltage and current changes with time and I–V characteristics for PKL unit cell, module, panel and array have also been studied. It is shown that the voltaic and energy efficiency have been studied. However, the highest efficiency was obtained for 40% PKL sap with 5% secondary salt in 55% aqueous solution, which implies that the concentration of PKL juice can play an important role regarding efficiency. It was also found that the average energy efficiency was 97.43% and it was also found that the average voltaic efficiency was 57.29%. Finally, morphological study FESEM (Field Emission Scanning Electron Microscopy) has also been performed. It is seen that the results confirmed that Zn was deposited on the Cu surface during the electro deposition process in PKL solution. Using AAS, it has been measured the concentration of [Cu2+] as a reactant ion and the concentration of [Zn2+] as a product ion those have been tabulated and graphically discussed. The variation of pH has also been studied with time and which was also tabulated and graphically discussed.
Considering the internet of things (IoT), end nodes such as wireless sensor network, RFID and embedded systems are used in many applications. These end nodes are known as resource-constrained devices in the IoT network. These devices have limitations such as computing and communication power, memory capacity and power. Key pre-distribution schemes (KPSs) have been introduced as a lightweight solution to key distribution in these devices. Key pre-distribution is a special type of key agreement that aims to select keys called session keys in order to establish secure communication between devices. One of these design types is the using of combinatorial designs in key pre-distribution, which is a deterministic scheme in key pre-distribution and has been considered in recent years. In this paper, by introducing a key pre-distribution scheme of this type, we stated that the model introduced in the two benchmarks of KPSs comparability had full connectivity and scalability among the designs introduced in recent years. Also, in recent years, among the combinatorial design-based key pre-distribution schemes, in order to increase resiliency as another criterion for comparing KPSs, attempts were made to include changes in combinatorial designs or they combine them with random key pre-distribution schemes and hybrid schemes were introduced that would significantly reduce the design connectivity. In this paper, using theoretical analysis and maintaining full connectivity, we showed that the strength of the proposed design was better than the similar designs while maintaining higher scalability.
Clinical narratives such as progress summaries, lab reports, surgical reports, and other narrative texts contain key biomarkers about a patient's health. Evidence-based preventive medicine needs accurate semantic and sentiment analysis to extract and classify medical features as the input to appropriate machine learning classifiers. However, the traditional approach of using single classifiers is limited by the need for dimensionality reduction techniques, statistical feature correlation, a faster learning rate, and the lack of consideration of the semantic relations among features. Hence, extracting semantic and sentiment-based features from clinical text and combining multiple classifiers to create an ensemble intelligent system overcomes many limitations and provides a more robust prediction outcome. The selection of an appropriate approach and its interparameter dependency becomes key for the success of the ensemble method. This paper proposes a hybrid knowledge and ensemble learning framework for prediction of venous thromboembolism (VTE) diagnosis consisting of the following components: a VTE ontology, semantic extraction and sentiment assessment of risk factor framework, and an ensemble classifier. Therefore, a component-based analysis approach was adopted for evaluation using a data set of 250 clinical narratives where knowledge and ensemble achieved the following results with and without semantic extraction and sentiment assessment of risk factor, respectively: a precision of 81.8% and 62.9%, a recall of 81.8% and 57.6%, an F measure of 81.8% and 53.8%, and a receiving operating characteristic of 80.1% and 58.5% in identifying cases of VTE. 相似文献
Scientometrics - Altmetrics are often praised as an alternative or complement to classic bibliometric metrics, especially in the social sciences discipline. However, empirical investigations of... 相似文献
Many occupations require workers to stand for long periods of time without proper interventions, which causes discomfort in the back and lower limbs. Therefore, this study aims to assess the effectiveness in alleviating body muscle discomfort during prolonged standing through the use of a calf massager. This study was conducted among male workers at a manufacturer with production line workers and the list was obtained from the HR Department and simple random sampling was done by number categorization. A total of 100 respondents (50 respondents for both the control and the experimental groups) participated in this study. The experiment took place in a room with a similar setup for the production line. Each respondent was requested to perform the simulated task for 2 hr. For the experimental group, the calf massager was turned on every 15 min. At every 15‐min interval after turning on the calf massager, respondents from both groups were required to evaluate their discomfort level on a Borg's scale CR‐10 questionnaire. The results showed that the level of body discomfort among respondents in the experimental group reduced (20–30%) compared with that of the control group. Multivariate analysis results revealed that the discomfort rating for the lower back, knees, thighs, calves, and feet was significantly lower (p < .05) among the experimental group compared with the control group. For lower body parts, the lower back region was statistically significant (p < .05) at the 90th, 105th, and 120th min; the thigh region was statistically significant (p < .05) at the 120th min; the knee region was statistically significant (p < .05) at the 105th and 120th min; the calf region was statistically significant (p < .05) at all minute intervals except the 15th and 45th min, while the feet region, was statistically significant at the 105th and 120th min. Therefore, this study indicates that calf massage treatment is capable of reducing body muscle discomfort during prolonged standing and highlights the significance of calf massage. 相似文献
Wireless Networks - Wireless sensor network (WSN) consists of small sized devices containing different sensors to monitor physical, environmental and medical conditions during surveillance of... 相似文献