首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   30篇
  免费   1篇
化学工业   5篇
能源动力   5篇
轻工业   1篇
无线电   1篇
一般工业技术   17篇
冶金工业   2篇
  2021年   1篇
  2018年   2篇
  2016年   1篇
  2013年   5篇
  2012年   2篇
  2011年   2篇
  2009年   2篇
  2008年   4篇
  2007年   2篇
  2006年   1篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
  2001年   1篇
  2000年   1篇
  1998年   2篇
  1997年   1篇
  1995年   1篇
排序方式: 共有31条查询结果,搜索用时 15 毫秒
1.
The performance of transcritical R744 systems with direct expansion (DX) can be significantly improved by implementing a Flash Gas Bypass (FGB). The idea behind the concept is to bypass refrigerant vapor, created during the isenthalpic expansion process, around the evaporator. By feeding the evaporator with liquid refrigerant, pressure drop is reduced and refrigerant distribution is improved. With R744 as the working fluid, increased refrigerant-side heat transfer coefficients are expected as well. In addition, the FGB concept proves to be beneficial in terms of system design, in particular for combined air-conditioning and heat pumping applications. An experimental comparison to a conventional DX-system reveals that FGB increases the cooling capacity and COP at the same time by up to 9 and 7%, respectively. Even larger improvements are possible in case a variable speed compressor is utilized to match the performance of the conventional DX-system. A simulation model helps to separate the individual improvement mechanisms. It was found that the reduction of refrigerant-side pressure drop is the dominant improvement mechanism of FGB.  相似文献   
2.
The compatibilizing effect of nano sized calcium carbonate filler on immiscible blends of styrene‐co‐acrylonitrile/ethylene propylene diene (SAN/EPDM) was examined. The surface energy of the calcium carbonate was modified by stearic acid. The compatibility of SAN/EPDM blends was studied by following the glass transition temperature Tg by DSC. SEM was used to observe the blend morphology and the X‐ray analyzer was used to detect the calcium from filler in samples. Mechanical properties of the blends were determined, and related to changes of polymer‐filler interactions and morphology. The results suggest that the morphology of the SAN/EPDM blends studied was affected by the reduction of surface energy of the filler.

SEM micrograph of an SAN/EPDM blend with 5% of maximally treated filler.  相似文献   

3.
This paper presents experimentally determined heat transfer coefficients for condensation from a superheated vapor of CO2 and R410A. The superheated vapor was flowed through a smooth horizontal tube with 6.1 mm ID under almost uniform temperature cooling at reduced pressures from 0.55 to 0.95, heat fluxes from 3 to 20 kW m?2, and superheats from 0 to 40 K. When the tube wall temperature reaches the saturation point, the measured results show that the heat transfer coefficient gradually starts deviating from the values predicted by a correlation valid for single-phase gas cooling. This point identifies the start of condensation from the superheated vapor. The condensation starts earlier at higher heat fluxes because the tube wall temperature reaches the saturation point earlier. The heat transfer coefficient reaches a value predicted by correlations for condensation at a thermodynamic vapor quality of 1. The measured heat transfer coefficient of CO2 is roughly 20–70% higher than that of R410A at the same reduced pressures. This is mainly because the larger latent heat and liquid thermal conductivity of CO2, compared to that of R410A, increase the heat transfer coefficient.  相似文献   
4.
An experimental investigation on two-phase flow boiling heat transfer with refrigerants of R-22, R-134a, R-410A, C3H8 and CO2 in horizontal circular small tubes is presented. The experimental data were obtained over a heat flux range of 5–40 kW m?2, mass flux range of 50–600 kg m?2 s?1, saturation temperature range of 0–15 °C, and quality up to 1.0. The test section was made of stainless steel tubes with inner diameters of 0.5, 1.5 and 3.0 mm, and lengths of 330, 1000, 1500, 2000 and 3000 mm. The experimental data were mapped on Wang et al. (1997) [5] and Wojtan et al. (2005) [6] flow pattern maps. The effects of mass flux, heat flux, saturation temperature and inner tube diameter on the heat transfer coefficient are reported. The experimental heat transfer coefficients were compared with some existing correlations. A new boiling heat transfer coefficient correlation that is based on a superposition model for refrigerants in small tubes is presented with 15.28% mean deviation and ?0.48% average deviation.  相似文献   
5.
This study presents experimental results obtained from a transcritical R744 system using a refrigerant ejector. The results were compared to that of a conventional system with an expansion valve. For the test conditions considered, the cooling capacity and COP simultaneously improved by up to 8% and 7%, respectively. Experiments were analyzed to quantitatively assess the effects on system performance as a result of changes in basic ejector dimensions such as motive nozzle and diffuser sizing. Small angles of 5° yielded best results for the static pressure recovery of the high-speed two-phase flow entering the diffuser. Experiments confirmed that like in a conventional transcritical R744 system with expansion valve, the high-side pressure control integrated into the ejector could be used to maximize the system performance. Numerical simulation results helped identifying this basic trend. Due to difficulties in the ejector throat pressure measurements, a more practical performance metric was introduced in order to quantify overall ejector efficiencies. According to this definition, the prototype ejector was able to recover up to 14.5% of the throttling losses.  相似文献   
6.
The effect of different type of condensers on the performance of R410A residential air-conditioning systems was investigated in this study. Two R410A residential air-conditioning systems, one with a microchannel condenser and the other with a round-tube condenser, were examined experimentally, while the other components of the two systems were identical except the condensers. Two condensers had almost same package volumes. The two systems were operated in separate environmental chambers and their performance was measured in ARI A, B, and C conditions. Both the COP and cooling capacity of the system with the microchannel condenser were higher than those for the round-tube condenser in all test conditions. The refrigerant charge amount and the refrigerant pressure drop were measured; the results showed a reduction of charge and pressure drop in the microchannel condenser. A numerical model for the microchannel condenser was developed and its results were compared with the experiments. The model simulated the condenser with consideration given to the non-uniform air distribution at the face of the condenser and refrigerant distribution in the headers. The results showed that the effect of the air and refrigerant distribution was not a significant parameter in predicting the capacity of the microchannel condenser experimentally examined in this study. Temperature contours, generated from the measured air exit temperatures, showed the refrigerant distribution in the microchannel condenser indirectly. The temperature contours developed from the model results showed a relatively good agreement with the contours for measured air exit temperatures of the microchannel condenser.  相似文献   
7.
The properties of styrene–acrylonitrile (SAN) and ethylene–propylene–diene (EPDM) blends containing different types of calcium carbonate filler were studied. The influence of mixing type process on the blend properties was also studied. Two different mixing processes were used. The first one includes mixing of all components together. The other process is a two‐step mixing procedure: masterbatch (MB; EPDM/SAN/filler blend) was prepared and then it was mixed with previously prepared polymer blend. Surface energy of samples was determined to predict the strength of interactions between polymer blend components and used fillers. The phase morphology of blends and their thermal and mechanical properties were studied. From the results, it can be concluded that the type of mixing process has a strong influence on the morphological, thermal, and mechanical properties of blends. The two‐step mixing process causes better dispersion of fillers in blends as well as better dispersion of EPDM in SAN matrix, and therefore, the finest morphology and improved properties are observed in blends with MB. It can be concluded that the type of mixing process and carefully chosen compatibilizer are the important factors for obtaining the improved compatibility of SAN/EPDM blends. © 2012 Wiley Periodicals, Inc. J Appl Polym Sci, 2012  相似文献   
8.

The early and accurate diagnosis of cardiovascular diseases (CVDs) are of great importance as they allow early and proper medical treatment and therefore result in reducing the chance of the CVDs being developed to an acute level. In medical procedures, the first step in examining the cardiovascular function is the auscultation of the heart. However, the correct medical diagnosis based on the heart sounds through a stethoscope requires a lot of expertise and, in some cases, needs referral of the patient to a cardiologist. This is not only time-consuming but also imposes a financial burden on the medical system. Thus, automated detection and analysis of the recorded heart sound auscultation has received a lot of attentions in recent years. This study presents a new time–frequency (T–F) based approach for classifying phonocardiogram (PCG) signals into normal and abnormal. In the proposed methodology, each PCG recording is first segmented into the 4 fundamental heart cycles, i.e. S1, systole, S2, and diastole. From each state, a set of T–F features are extracted with the aim of identifying their characteristics in the T–F domain. The features are then applied to a support vector machine to classify the PCG signal into normal or abnormal. The performance of the proposed method is evaluated using the 2016 PhysioNet challenge database and compared with that of the best performing existing methods. The experimental results using tenfold cross-validation show that the proposed method outperforms the existing methods in terms of sensitivity, specificity, and accuracy.

  相似文献   
9.
The thermal-hydraulic performance under conditions of an initial frost growth on the air-side surface, and for subsequent ‘refrosting’ after a defrost period is experimentally studied for folded-louvered-fin, microchannel heat exchangers. In total, five heat exchangers are considered; the thermal performances during one frost-growth cycle for four different fin geometries are compared in terms of overall heat transfer coefficient, pressure drop, and j and f factors; the defrost and refrost characteristics of two heat exchangers are compared to explore geometry effects. Typically, the performance under refrosting conditions becomes periodic and repeatable after the third or fourth refrosting cycle. The allowable frost growth period (before a defrost is required), the defrost requirement, and the thermal-hydraulic performance depend on heat exchanger geometry for the specimens used in this study.  相似文献   
10.
The effect of sulfur accelerators during the curing process in natural rubber (NR) was investigated. The samples were prepared by adding the same fraction of various types of accelerators in the compound and all samples were cured at the same temperature but for two different times. Determination of the molecular mass between crosslinks immediately after vulcanization shows the crosslink density in the samples, which differs for different accelerators. After that, the same samples undergo thermal aging and the changes of the crosslink density were studied. During the first period of thermal aging, additional crosslinks were observed and then a period of deterioration of the network structure is following. From the obtained results of the molecular mass between crosslinks as well as from mechanical properties, conclusions can be drawn about the most suitable accelerator for use in certain conditions and applications. To predict the behavior of vulcanizates under various effects as heat and radiation, it is important to know more about the chemical structure of the network. The changes of crosslink density in the investigated samples were followed by equilibrium swelling and by mechanical measurements. IR spectroscopy was used to study the changes of the crosslink bridges.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号