首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   19篇
  免费   3篇
化学工业   2篇
机械仪表   1篇
建筑科学   1篇
能源动力   1篇
轻工业   3篇
无线电   3篇
一般工业技术   5篇
冶金工业   4篇
自动化技术   2篇
  2023年   1篇
  2022年   1篇
  2021年   6篇
  2020年   3篇
  2018年   2篇
  2017年   2篇
  2016年   2篇
  1997年   3篇
  1996年   1篇
  1994年   1篇
排序方式: 共有22条查询结果,搜索用时 15 毫秒
1.
Electroencephalography (EEG) is widely used in variety of research and clinical applications which includes the localization of active brain sources. Brain source localization provides useful information to understand the brain's behavior and cognitive analysis. Various source localization algorithms have been developed to determine the exact locations of the active brain sources due to which electromagnetic activity is generated in brain. These algorithms are based on digital filtering, 3D imaging, array signal processing and Bayesian approaches. According to the spatial resolution provided, the algorithms are categorized as either low resolution methods or high resolution methods. In this research study, EEG data is collected by providing visual stimulus to healthy subjects. FDM is used for head modelling to solve forward problem. The low‐resolution brain electromagnetic tomography (LORETA) and standardized LORETA (sLORETA) have been used as inverse modelling methods to localize the active regions in the brain during the stimulus provided. The results are produced in the form of MRI images. The tables are also provided to describe the intensity levels for estimated current level for the inverse methods used. The higher current value or intensity level shows the higher electromagnetic activity for a particular source at certain time instant. Thus, the results obtained demonstrate that standardized method which is based on second order Laplacian (sLORETA) in conjunction with finite difference method (FDM) as head modelling technique outperforms other methods in terms of source estimation as it has higher current level and thus, current density (J) for an area as compared to others.  相似文献   
2.
The barriers for the encapsulation and decapsulation of hydrogen ions (cationic hydrogen and hydride), atom, and molecule through silicon carbide nanotube are thoroughly studied. DFT method is selected to measure the kinetic barriers for the passage of hydrogen atom, ions and molecule through nanotube via scanning potential energy surface. The kinetic barriers for the passage (encapsulation and decapsulation) of hydrogen are very important to understand the mechanism of hydrogen storage and release. The barriers for the permeation of H, H+ and H? across SiC nanosheet are lower compared to hydrogen molecule (H2). The exohedral and endohedral adsorption of hydrogen ions (cation and anion), atom and exohedral hydrogen molecule on silicon carbide are exothermic in nature. Whereas the encapsulation of hydrogen molecule in silicon carbide is endothermic. Electronic properties are analyzed through measurement of energy gap between highest occupied and lowest unoccupied molecular orbitals gap (GH-L) and the density of state (DOS) spectra. The GH-L analysis reveals that endohedral complexes have more pronounced effect on electronic properties compared to exohedral complexes. The SiC nanotube has highly favorable properties for storage and release of hydrogen ions, and atom.  相似文献   
3.
Disinfection practices reduce the incidence of water‐borne diseases but may result in formation of disinfection byproducts (DBPs) in raw water that are reported to be carcinogenic. Central composite design (CCD) was employed in the present study for optimization of disinfectant dose and contact time with the rationale to evaluate if an optimal balance could be achieved between minimal DBPs formation and effective microbial inactivation with either free or combined chlorine in treated water within a lab‐scale prototype network to simulate real water distribution network conditions. After a series of experimental runs based upon design of experiments (DoE) by CCD, dose was found to be the most significant factor (P < 0.01) in determining DBPs formation in both disinfectant’s applications. Where, contact time significantly (P < 0.01) affected bacterial inactivation in chlorination experiments, in contrast, dose was effective in chloramination experiments. Thus, it was concluded that the optimal balance may be achieved in the water networks with the help of multifactorial optimization when disinfectant dose was maintained near 3 mg/L as applied chlorine dose in both disinfection cases, while contact time was 62 and 155 min for chlorine and chloramine, respectively.  相似文献   
4.
The first step of urine formation is the selective filtration of the plasma into the urinary space at the kidney structure called the glomerulus. The filtration barrier of the glomerulus allows blood cells and large proteins such as albumin to be retained while eliminating the waste products of the body. The filtration barrier consists of three layers: fenestrated endothelial cells, glomerular basement membrane, and podocytes. Podocytes are specialized epithelial cells featured by numerous, actin-based projections called foot processes. Proteins on the foot process membrane are connected to the well-organized intracellular actin network. The Rho family of small GTPases (Rho GTPases) act as intracellular molecular switches. They tightly regulate actin dynamics and subsequent diverse cellular functions such as adhesion, migration, and spreading. Previous studies using podocyte-specific transgenic or knockout animal models have established that Rho GTPases are crucial for the podocyte health and barrier function. However, little attention has been paid regarding subcellular locations where distinct Rho GTPases contribute to specific functions. In the current review, we discuss cellular events involving the prototypical Rho GTPases (RhoA, Rac1, and Cdc42) in podocytes, with particular focus on the subcellular compartments where the signaling events occur. We also provide our synthesized views of the current understanding and propose future research directions.  相似文献   
5.
Point-of-care testing (POC) has the ability to detect chronic and infectious diseases early or at the time of occurrence and provide a state-of-the-art personalized healthcare system. Recently, wearable and flexible sensors have been employed to analyze sweat, glucose, blood, and human skin conditions. However, a flexible sensing system that allows for the real-time monitoring of throat-related illnesses, such as salivary parotid gland swelling caused by flu and mumps, is necessary. Here, for the first time, a wearable, highly flexible, and stretchable piezoresistive sensing patch based on carbon nanotubes (CNTs) is reported, which can record muscle expansion or relaxation in real-time, and thus act as a next-generation POC sensor. The patch offers an excellent gauge factor for in-plane stretching and spatial expansion with low hysteresis. The actual extent of muscle expansion is calculated and the gauge factor for applications entailing volumetric deformations is redefined. Additionally, a bluetooth-low-energy system that tracks muscle activity in real-time and transmits the output signals wirelessly to a smartphone app is utilized. Numerical calculations verify that the low stress and strain lead to excellent mechanical reliability and repeatability. Finally, a dummy muscle is inflated using a pneumatic-based actuator to demonstrate the application of the affixed wearable next-generation POC sensor.  相似文献   
6.
Stretchable electronics can be used for numerous advanced applications such as soft and wearable actuators, sensors, bio-implantable devices, and surgical tools because of their ability to conform to curvilinear surfaces, including human skin. The efficacy of these devices depends on the development of stretchable geometries such as interconnection-based configurations and the associated mechanics that helps to achieve optimum configurations. This work presents the essential mechanics of silicon (Si) island-interconnection structures, which include horseshoe and spiral interconnections, without reducing the areal efficiency. In particular, this study demonstrates the range of the geometrical parameters where they have a high stretchability and cyclic life. The numerical results predict the areas that are prone to breaking followed by experimental validation. The figure-of-merit for these configurations is achieved by mapping the fracture-free zones for in-plane and out-of-plane stretching with essential implications in stretchable and wearable system design. Furthermore, this work demonstrates the mechanical response for a range of materials (i.e., copper, gold, aluminum, silver, and graphene) that experience the plastic deformations in contrast to conventionally used Si-based devices that represent the extended usage for advanced stretchable electronic devices. The detailed mechanics of these configurations provides comprehensive guidelines to manufacture wearable and stretchable electronic devices.  相似文献   
7.
Lungs from eight goats of mixed sexes and breeds (Cashmere, Nubian and Toggenburg) aged between 10 and 48 months were used in this study. Tissues from lung parenchyma were minced and routinely prepared for transmission electron microscopy (TEM) after using different methods of fixation. Thick sections were examined with a light microscope and samples, to include terminal bronchioles, respiratory bronchioles, alveolar ducts and alveolar membrane, were selected for ultrathin sectioning. Six cell types, ciliated, non-ciliated bronchiolar epithelial, mucus-producing, alveolar Type I, alveolar Type II and capillary endothelial cell were identified and characterised cytologically. It was established that the cell population in the distal airways is similar to that observed in other domestic mammals. The mucus-producing cell, which appears to be a common cell type in the distal airways of man and Rhesus monkey, was encountered particularly in adult goats in the present study. This study has also established that the Clara cell of the goat shows some cytological differences from those of some other mammalian species by having a large amount of SER, particularly in the apical region. Lipid vacuoles were seen to be a feature of the alveolar Type II cells; these do not appear to have been reported in other mammalian species. The study has provided a basic understanding of the morphological features of the cell population of the epithelium lining the distal airways in the goat's respiratory tract. The difference in junctional complexes between the various alveolar epithelial cells perhaps signify a different pattern of intercellular transport, thus influencing the pathogenesis and resolution of alveolar pulmonary edema.  相似文献   
8.
The feasibility of achieving both universal application of nonthoracotomy leads and low (< or = 15 J) defibrillation energy requirements by optimizing lead system configuration for use with low-output (<30 J) biphasic shock pulse generators was examined. Sixteen patients (mean age 62 +/- 8 years and mean left ventricular ejection fraction of 38 +/- 15%) were included in the study. All patients had either experienced syncope with induced ventricular tachycardia (n = 4) or had documented sustained ventricular tachycardia (n = 7) or ventricular fibrillation (n = 5). Defibrillation threshold testing was performed in 2 stages on different days in these patients. In the first stage, 2 defibrillation catheter electrodes were positioned in the right ventricle and superior vena cava with an axillary cutaneous patch. Fifteen-joule, 10- and 5-J biphasic shocks were delivered across 3 different electrode configurations-right ventricle to superior vena cava, right ventricle to axillary patch, right ventricle to a combination of superior vena cava and axillary patch. In the second stage, an 80-ml can electrode was added subcutaneously in a pectoral location to the previous leads. Configurations compared were the right ventricle to pectoral can, and right ventricle to an "array"-combining superior vena cava, can, and axillary patch leads. The defibrillation threshold was determined using a step-down method. In stage 1, mean defibrillation threshold for the right ventricle to axillary patch (12.7 +/- 5.9 J) and right ventricle to superior vena cava plus axillary patch (9.8 +/- 5.2 J) configurations was lower than the right ventricle to superior vena cava configuration (14.2 +/- 6.4 J, p <0.05). In stage 2, the defibrillation was higher for the right ventricle to pectoral can (9.2 +/- 5.1 J) configuration compared with the right ventricle to the array (5.6 +/- 3.6 J, p < or =0.05). The right ventricle to array had the lowest defibrillation threshold, whereas the right ventricle to pectoral can was the best dual electrode system. Low-energy endocardial defibrillation (< or =10 J) was feasible in 72% of tested patients with > 1 electrode configuration at 10 J, whereas only 53% of successful patients could be reverted at >1 electrode configuration at 5 J (p <0.05). Reduction in maximum pulse generator output to < or =25 J using these electrode configurations with bidirectional shocks is feasible and maintains an adequate safety margin.  相似文献   
9.
This paper developed new and efficient image watermarking scheme for copyright protection based on Lifting wavelet transform (LWT) and Bi- dimensional Empirical Mode Decomposition (BEMD). A LWT has been selected because it is fast, less computational cost and maintains the integrity of the recovered watermark. The BEMD transform can separate the image from the most robust to the least sensitive or fragile frequency bands. This advantage is utilised in this study for the purpose of embedding the watermark in the robust part of BEMD, i.e. the residue (r). In addition, the embedding process has been performed in the low sub-band of LWT decomposed image as the low sub-band is more robust to image processing such as JPEG compression. The robust watermark which is grey scale image is decomposed using DWT to enhance the security and select only high sub-band as it has less impact on the quality of the watermarked image. As a result, the original image’s visual quality can be preserved and the concealed watermark could be successfully retrieved even if the watermarked images have undergone severe attacks like JPEG, rotation, Gamma correction, filtering, additive noise, translation, shearing, and scaling. Furthermore, the improved scheme offers greater robustness against many image processing operations, in comparison to the current schemes about copyright protection.  相似文献   
10.
OBJECTIVES: We investigated 1) the feasibility, safety and efficacy of multisite right atrial pacing for prevention of atrial fibrillation (AF); and 2) the ability of atrial pacing in single- and dual-site modes to increase arrhythmia-free intervals in patients with drug-refractory AF. BACKGROUND: We recently developed and applied a novel technique of dual-site right atrial pacing in an unselected group of consecutive patients with AF requiring demand pacing. A prospective crossover study design was used to evaluate single- and dual-site right atrial pacing modes. METHODS: The frequency of AF during the 3 months before pacemaker implantation was analyzed. Consecutive consenting patients underwent insertion of two atrial leads and one ventricular lead with a DDDR pulse generator. Patients were placed in a dual-site pacing mode for the first 3 months and subsequently mode switched to single site pacing for 3 months. Mode switching was repeated at 6-month intervals thereafter. RESULTS: Atrial pacing resulted in a marked decline in AF recurrences (p < 0.001). During dual-site pacing with an optimal drug regimen, there was no AF recurrence in any patient compared with five recurrences in 12 patients during single-site pacing (p = 0.03). The mean (+/-SD) arrhythmia-free interval before pacing (14 +/- 14 days) was prolonged with dual- (89 +/- 7 days, p < 0.0001) and single-site pacing (76 +/- 27 days, p < 0.0001). Symptomatic AF episodes showed a declining trend during dual- and single-site pacing compared with those during the preimplantation period (p = 0.10). Mean antiarrhythmic drug use for all classes declined from 4 +/- 1.9 drugs before implantation to 1.5 +/- 0.5 (p < 0.01) drugs after implantation. Twelve (80%) of 15 patients remained in atrial paced rhythm at 13 +/- 3 months. CONCLUSIONS: We conclude that multisite right atrial pacing is feasible, effective and safe for long-term application. Atrial pacing significantly prolongs arrhythmia-free intervals in patients with drug-refractory paroxysmal AF. Dual-site right atrial pacing may offer additional benefits and should be considered either as the primary mode or in patients unresponsive to single-site pacing.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号