With lower alloying cost and higher mechanical properties, lean duplex stainless steels can be an alternative to the more commonly used austenitic stainless steels. However, these alloys are still not the preferred choice, probably due to a lack of field experience. A study was thus initiated in view of defining the limits of use of selected (lean) duplexes for urban wastewater treatment units. The present paper shows the localized corrosion performance of selected lean duplexes in chloride contaminated solutions. The results are compared with austenitic S30403 and S31603 and with the more standard duplexes S82441 and S32205. The effect of welding was also investigated. Exposures in field municipal wastewater plants were conducted for 1 year in low and high chloride content units. The results show that lean duplexes S32101 and S32202 can be used as alternatives to S30403 and S31603 in low chloride electrolytes. At 500 ppm of chloride content, duplex stainless steel S32304 showed better corrosion resistance than S30403 and S31603. For higher chloride contents (1000 ppm and above) the standard duplexes S82441 and S32205 shall be preferred. 相似文献
Over the past decades, the number of patients with dry eye disease (DED) has increased dramatically. The incidence of DED is higher in Asia than in Europe and North America, suggesting the involvement of cultural or racial factors in DED etiology. Although many definitions of DED have been used, discrepancies exist between the various definitions of dry eye disease (DED) used across the globe. This article presents a clinical consensus on the definition of DED, as formulated in four meetings with global DED experts. The proposed new definition is as follows: “Dry eye is a multifactorial disease characterized by a persistently unstable and/or deficient tear film (TF) causing discomfort and/or visual impairment, accompanied by variable degrees of ocular surface epitheliopathy, inflammation and neurosensory abnormalities.” The key criteria for the diagnosis of DED are unstable TF, inflammation, ocular discomfort and visual impairment. This definition also recommends the assessment of ocular surface epitheliopathy and neurosensory abnormalities in each patient with suspected DED. It is easily applicable in clinical practice and should help practitioners diagnose DED consistently. This consensus definition of DED should also help to guide research and clinical trials that, to date, have been hampered by the lack of an established surrogate endpoint. 相似文献
People spend approximately 80% of their time indoor, making the understanding of the indoor chemistry an important task for safety. The high surface-area-to-volume ratio characteristic of indoor environments leads the semi-volatile organic compounds (sVOCs) to deposit on the surfaces. Using a long path absorption photometer (LOPAP), this work investigates the formation of nitrous acid (HONO) through the photochemistry of adsorbed nitrate anions and its enhancement by the presence of furfural. Using a high-resolution proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS), this work also investigates the surface emissions of VOCs from irradiated films of furfural and a mix of furfural and nitrate anions. Among the emitted VOCs, 2(5H)-furanone/2-Butenedial was observed at high concentrations, leading to maleic anhydride formation after UV irradiation. Moreover, the addition of potassium nitrate to the film formed NOx and HONO concentrations up to 10 ppb, which scales to ca. 4 ppb for realistic indoor conditions. This work helps to understand the high levels of HONO and NOx measured indoors. 相似文献
In this paper, we report on the design, fabrication, and characterization of blazed gratings made tunable by electrostatic actuation. We combine KOH etching and deep-reactive ion etching (DRIE) to fabricate tunable blazed gratings (TBGs) on silicon-on-insulator wafers with optical-quality mirror surfaces on {111} crystalline planes. The actuators that are used to position the individual grating elements are designed to reduce rotation to levels acceptable for spectroscopic applications. We characterize the fabricated devices mechanically, verify the rotation-reduction design, and demonstrate the functionality of TBGs as tunable filters. 相似文献
The experiments reported in this paper demonstrate the causes of the failure of monolithic ceramics. The specimens are made of silicon nitride and tested at room temperature. The stress field within the specimen is different for each of four series of tests that have been conducted. Fractographic observations have also been made to identify the causes of the failures. A size effect analysis is performed. 相似文献
A 3-factor solution of the Wechsler Adult Intelligence Scale—Revised (WAIS—R; Wechsler, 1981) in 260 adults with suspected head injury suggested relatively good construct validity for the factors, based on correlations with neuropsychological tests purported to measure similar abilities. The Verbal Comprehension factor was related to verbal ability, verbal memory, and executive functioning. The Perceptual Organization factor, although measuring primarily visual–spatial perception and visual constructional ability, was related to visual–spatial memory, visual attention, and executive functioning. The Freedom From Distractibility factor was correlated with two attention measures and was not associated with memory measures. Its association with executive functioning was inconsistent. The findings are discussed in terms of the multidimensional nature of neuropsychological tests and WAIS—R factors. (PsycINFO Database Record (c) 2011 APA, all rights reserved) 相似文献
A probabilistic risk assessment (PRA) model, developed for the Thermal Protection System (TPS) of the space shuttle orbiter and presented in the previous paper, is used as a management tool to identify root-cause, organizational factors of the various failure modes. The objective is to set priorities in the process of resource allocation to minimize the risk of accident caused by the failure of the TPS. Starting with the technical characteristics of the system and the inputs of the risk assessment model, the approach is to identify the human decisions and actions and the key organizational factors that influence the risk.
Among the management factors that affect the reliability of the TPS are time pressures that have occurred in the past, liability concerns and conflicts among contractors, the low status of the tile work and material technicians among maintenance personnel, the absence of priorities in tile testing, and under-recognized couplings among subsystems (such as the external tank insulation as a source of debris that may hit the tiles). It is shown here how using the PRA results to set priorities in the maintenance of the tiles can allow reduction of the overall risk, and how critical zones of debris sources can be identified on the surface of the external tank and the solid rocket booster. It was found, for instance, that detecting and fixing loose tiles in the most risk-critical areas and securing insulation by up to 80%, and securing the insulation of external systems in specified areas could reduce the TPS risk by about 75%. 相似文献