首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
轻工业   4篇
一般工业技术   2篇
  2014年   1篇
  2013年   1篇
  2011年   1篇
  2008年   1篇
  2007年   2篇
排序方式: 共有6条查询结果,搜索用时 491 毫秒
1
1.
ORGANIC ACIDS PROFILE IN TOMATO JUICE BY HPLC WITH UV DETECTION   总被引:1,自引:0,他引:1  
A simple method was developed to determine 10 organic acids simultaneously in tomato products using reversed‐phase high‐performance liquid chromatography column with the diode array detector set at 210 nm. After centrifugation and filtration, the samples were passed through an anion exchange resin and the organic acids were released using 0.1‐N HCl. The chromatographic separation was achieved with isocratic analysis in a 20‐min run. The method was reliable and sensitive, the coefficient of determination of the standard calibration curve is 0.9925 ≤ r20.9999 and the limit of detection ranged from 0.08 to 6.00 mg/kg for trans‐aconitic acid and acetic acid, respectively. The limit of quantification ranged from 0.19 to 15.18 mg/kg for trans‐aconitic and acetic acid, respectively. To establish the efficiency of the anion resin, the procedure was applied to a standard solution of a mixture of organic acids. The organic acids recovery ranged from 87.0% ± 1.9 for citramalic acid to 109.9% ± 5.2 for fumaric acid.  相似文献   
2.
3.
The objective of this study is to design new hybrid silica materials as templates with hydrophobic properties, prepared at room temperature by a base catalyzed sol–gel process. As silica sources, organoalkoxysilanes functionalized with short hydrophobic chains were used: tetraethylorthosilicate (TEOS), methyltriethoxysilane (MTES), vinyltriethoxysilane (VTES), octyltriethoxysilane (OTES) and isobutyltriethoxysilane (iTES). It was shown that hydrophobicity of the functionalized silica nanoparticles increased as a function of length of the aliphatic chains (MTES < iTES < OTES) or when, instead of a hydrophobic alkyl chains (substituting group of silica precursors), a monounsaturated group was used (VTES). It was observed that the samples responded in a specific way to each type (hydrophilic or hydrophobic) of the dropped liquid. Even though the experiments were limited to short hydrocarbon chains, they showed that there is a threshold to reach high hydrophobicity of the hybrid surface.  相似文献   
4.
5.
A simple method was developed to determine 10 organic acids simultaneously in tomato products using reverse‐phase high performance liquid chromatography (HPLC) column with the diode array detector set at 210 nm. After centrifugation and filtration, the samples were passed through to an anion exchange resin and the organic acids were released using 0.1 N HCl. The chromatographic separation was achieved with isocratic analysis in a 20‐min run. The method was reliable and sensitive. The coefficient of determination of the standard calibration curve is 0.9925 ≤ r20.9999 and the limit of detection ranged from 0.08 to 6.00 mg/kg for trans‐aconitic acid and acetic acid, respectively. The limit of quantification ranged from 0.19 to 15.18 mg/kg for trans‐aconitic and acetic acid, respectively. To establish the efficiency of the anion resin the procedure was applied to a standard solution of a mixture of organic acids. The organic acids recovery ranged from 87.0% ± 1.9 for citramalic acid to 109.9% ± 5.2 for fumaric acid.  相似文献   
6.
The plate/screen-type electrostatic separator presented in this article provides a user-friendly environment for the experimental modeling of existing industrial units and facilitates investigations aiming at identifying new possibilities for using electric field forces for processing mixed granular solids. This multifunctional unit can be equipped with two different active electrodes, which can be energized from one or two independent high-voltage supplies, and the operator has the choice between two types of grounded electrodes: plate and plate/screen. The experiments carried out on a 50% quartz-50% magnetite mixture demonstrate that the efficiency of the separation can be increased by using a grounded plate/screen electrode and two high-voltage electrodes, energized from different supplies.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号