排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
2.
3.
The authors present a unified approach to three eigendecomposition-based methods for frequency estimation in the presence of noise. These are the Tufts-Kumaresan (TK) method, the minimum-norm (MN) method, and the total least squares (TLS) method. It is shown that: (1) the MN method is a modified version of the TK method; (2) the TLS method is a generalization of the MN method; (3) the TLS solution vector can be expressed in matrix form, and an alternative way of computing it is presented; (4) the MN and the TLS methods exhibit some improvement over the TK method 相似文献
4.
Several methods for canceling ground clutter in Doppler weather radars which operate with staggered pulse repetition times (PRTs) are investigated. A scheme is developed which consists of two filters that operate sequentially, so that the overall filter is time-varying, with periodically changing coefficients. This filter is analyzed theoretically and through simulations for a stagger ratio of 3/2, which extends the unambiguous velocity interval. The amplitude characteristic of the filter over this interval is very good, but the phase characteristic, which is nonlinear in a small part of the interval, requires that a special decision logic be used for velocity estimation 相似文献
5.
6.
Mladen S. Banjanin 《电力部件与系统》2017,45(11):1173-1181
In this paper, application of gapless transmission line arresters (TLAs) in substation lightning protection is analyzed. Deterministic calculations in accordance with IEC 62305 are performed. Substations with non-standard configuration equipped with Gas Insulated Switchgear (GIS), long cables, and a direct cable connecting GIS and power transformer are considered. It is concluded that 220- and 400-kV substations lightning performance can be significantly improved by using TLAs at only one or two overhead line towers in front of the substation. In some cases, TLAs provide better lightning protection of power transformer than surge arresters installed in GIS. Positive effects of TLAs application are noticed both in the case of back-flashovers and in the case of shielding failures. TLAs energy stress increases with the decrease of the system rated voltage. Maximum estimated values in the analyzed substations are below 2.5 and 0.5 kJ/kVr for TLAs installed in 220- and 400-kV systems, respectively. 相似文献
7.
8.
9.
Zoran S. Petrovi Michal Ilavský Karel Dusek Mladen Vidakovi Ivan Javni bozo Banjanin 《应用聚合物科学杂志》1991,42(2):391-398
A series of segmented polyurethanes from two polyols, 4,4′-diphenylmethane diisocyanate (MDI) and butane diol was synthesized. The degree of chemical crosslinking was controlled by varying the ratio of poly(oxypropylene) diol to poly(oxypropylene/oxyethylene) triol. The samples were prepared at the stoichiometric ratio of NCO to OH groups and at a constant concentration of hard segments (butane diol; MDI) equal 50 wt %. At low concentrations of the triol the molecular weight of the polyurethanes increases; at higher concentrations (above 9 mol %) crosslinked products are obtained. All samples show a distinct two-phase structure and in the region of 0–150°C the dynamic mechanical behavior is affected by the hard phase. Chemical crosslinking was found to increase the tensile strength and strain at break, but did not affect appreciably the tear strength, hardness, and soft segment glass transition. The stress relaxation rate at room temperature was found to depend both on the elongation and on the degree of crosslinking. A comparison of the sol fractions ws found for crosslinked samples with the predictions of the theory of branching processes proved that the achieved conversions of reactive groups in networks are high (~ 0.98). 相似文献