排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
V. M. Bazovkin N. A. Valisheva A. A. Guzev V. M. Efimov A. P. Kovchavtsev G. L. Kuryshev I. I. Lee V. G. Polovinkin A. S. Stroganov 《Optoelectronics, Instrumentation and Data Processing》2007,43(4):332-336
A design and parameters of the IR spectrograph based on an MS2004I monochromator-spectrograph and a hybrid microcircuit of a one-dimensional 1 × 384 InAs focal plane array for registration of fast processes (the registration time from 0.2 ms) are presented. The obtained spectral resolution is 0.3 nm/element at a wavelength of 1.7 μm. The wavelength range registered in a fixed position of the diffraction grating at this wavelength is 118 nm. 相似文献
2.
Coherent distortion risk measures are applied to capture the possible violation of a restriction in linear optimization problems whose parameters are uncertain. Each risk constraint induces an uncertainty set of coefficients, which is proved to be a weighted-mean trimmed region. Thus, given a sample of the coefficients, an uncertainty set is a convex polytope that can be exactly calculated. We construct an efficient geometrical algorithm to solve stochastic linear programs that have a single distortion risk constraint. The algorithm is available as an R-package. The algorithm’s asymptotic behavior is also investigated, when the sample is i.i.d. from a general probability distribution. Finally, we present some computational experience. 相似文献
3.
I. I. Lee V. M. Bazovkin N. A. Valisheva A. A. Guzev V. M. Efimov A. P. Kovchavtsev G. L. Kuryshev V. G. Polovinkin A. S. Stroganov A. V. Tsarenko 《Optoelectronics, Instrumentation and Data Processing》2007,43(4):322-331
Results of experimental investigation of thermography systems based on InAs CID elements of line and matrix hybrid modules (a thermal imager and IR microscope) are presented. Owing to a high time stability, in the short-wave IR range, the implemented thermography systems have a temperature resolution of ~(4–8) mK for an effective frame frequency of 1–10 Hz. 相似文献
4.
V. M. Bazovkin I. V. Mzhel’skii G. L. Kuryshev V. G. Polovinkin 《Optoelectronics, Instrumentation and Data Processing》2011,47(5):498-502
Technical parameters and possible applications of an infrared scanning microscope with a spatial resolution of up to 3 μm
are considered. It is shown that the device works with both array and linear photodetectors. Original PC software was designed
to control the scanning process interactively and receive and process images of objects in the infrared range,. 相似文献
5.
I. I. Lee V. M. Bazovkin N. A. Valisheva A. A. Guzev V. M. Efimov A. P. Kovchavtsev G. L. Kuryshev V. G. Polovinkin A. S. Stroganov A. V. Tsarenko 《Optoelectronics, Instrumentation and Data Processing》2007,43(4):314-321
Problems of using charge-injected devices in hybrid infrared focal plane arrays are considered. 相似文献
6.
Bazovkin V. M. Varavin V. S. Vasil’ev V. V. Glukhov A. V. Gorshkov D. V. Dvoretsky S. A. Kovchavtsev A. P. Makarov Yu. S. Marin D. V. Mzhelsky I. V. Polovinkin V. G. Remesnik V. G. Sabinina I. V. Sidorov Yu. G. Sidorov G. Yu. Stroganov A. S. Tsarenko A. V. Yakushev M. V. Latyshev A. V. 《Journal of Communications Technology and Electronics》2019,64(9):1011-1015
Journal of Communications Technology and Electronics - Abstract—The characteristics of MWIRs focal plane aeeays made in the form of a hybrid chip based on a planar n+–p-HgCdTe focal... 相似文献
7.
A. G. Verkhoglyad I. N. Kuropyatnik V. M. Bazovkin G. L. Kuryshev 《Russian Journal of Nondestructive Testing》2008,44(10):664-668
A method for detecting a through crack in a disc of a railway wheel by an infrared camera or a thermal imager is developed. It is based on registering of the evolution of the temperature distribution on the surface of the wheel disc during its heating. The experimental data considered confirm the possibility of crack detection by the infrared technique. 相似文献
1