全文获取类型
收费全文 | 64篇 |
免费 | 2篇 |
专业分类
化学工业 | 8篇 |
能源动力 | 1篇 |
轻工业 | 13篇 |
无线电 | 10篇 |
一般工业技术 | 1篇 |
冶金工业 | 28篇 |
自动化技术 | 5篇 |
出版年
2022年 | 3篇 |
2021年 | 1篇 |
2018年 | 3篇 |
2017年 | 1篇 |
2015年 | 1篇 |
2014年 | 1篇 |
2013年 | 1篇 |
2012年 | 2篇 |
2009年 | 2篇 |
2007年 | 2篇 |
2006年 | 2篇 |
2005年 | 6篇 |
2004年 | 4篇 |
2001年 | 1篇 |
1998年 | 13篇 |
1997年 | 11篇 |
1996年 | 3篇 |
1995年 | 1篇 |
1993年 | 2篇 |
1988年 | 1篇 |
1985年 | 1篇 |
1980年 | 2篇 |
1978年 | 1篇 |
1977年 | 1篇 |
排序方式: 共有66条查询结果,搜索用时 15 毫秒
1.
2.
Efficient application identification and the temporal and spatial stability of classification schema
Motivated by the importance of accurate identification for a range of applications, this paper compares and contrasts the effective and efficient classification of network-based applications using behavioral observations of network-traffic and those using deep-packet inspection.Importantly, throughout our work we are able to make comparison with data possessing an accurate, independently determined ground-truth that describes the actual applications causing the network-traffic observed.In a unique study in both the spatial-domain: comparing across different network-locations and in the temporal-domain: comparing across a number of years of data, we illustrate the decay in classification accuracy across a range of application–classification mechanisms. Further, we document the accuracy of spatial classification without training data possessing spatial diversity.Finally, we illustrate the classification of UDP traffic. We use the same classification approach for both stateful flows (TCP) and stateless flows based upon UDP. Importantly, we demonstrate high levels of accuracy: greater than 92% for the worst circumstance regardless of the application. 相似文献
3.
Rahul S. Kalhapure Pradeep Bolla Delfina C. Dominguez Amit Dahal Sai H.S. Boddu Jwala Renukuntla 《IET nanobiotechnology / IET》2018,12(6):836
Silver (Ag) complexes of drugs and their nanosystems have great potential as antibacterials. Recently, an Ag complex of furosemide (Ag–FSE) has shown to be a promising antimicrobial. However, poor solubility of Ag–FSE could hamper its introduction into clinics. Therefore, the authors developed a nanosuspension of Ag–FSE (Ag–FSE_NS) for its solubility and antibacterial activity enhancement. The aim of this study was to introduce a novel nanoantibiotic with enhanced antibacterial efficacy. Ag–FSE_NS was prepared by precipitation–ultrasonication technique. Size, polydispersity index (PI) and zeta potential (ZP) of prepared Ag–FSE_NS were measured by dynamic light scattering, whereas surface morphology was determined using scanning electron microscopy (SEM). In vitro antibacterial activity was evaluated against Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa using broth microdilution method. Size, PI and ZP of optimised Ag–FSE_NS1 were 191.2 ± 19.34 nm, 0.465 ± 0.059 and −55.7 ± 8.18 mV, respectively. SEM revealed that Ag–FSE_NS1 particles were rod or needle‐like with smooth surfaces. Saturation solubility of Ag–FSE in NS increased eight‐fold than pure Ag–FSE. Ag–FSE_NS1 exhibited two‐fold and eight‐fold enhancements in activity against E. coli and S. aureus, respectively. The results obtained showed that developed Ag–FSE_NS1 holds a promise as a topical antibacterial.Inspec keywords: nanomedicine, nanofabrication, light scattering, surface morphology, silver, particle size, solubility, suspensions, scanning electron microscopy, electrokinetic effects, drugs, biomedical materials, antibacterial activity, microorganisms, nanoparticles, drug delivery systems, transmission electron microscopyOther keywords: saturation solubility, topical antibacterial, size 171.86 nm to 210.54 nm, voltage ‐47.52 mV to ‐63.88 mV, Ag, broth microdilution method, Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus, SEM, scanning electron microscopy, surface morphology, dynamic light scattering, particle size, polydispersity index, precipitation–ultrasonication technique, nanoantibiotic, nanosuspension, furosemide, nanosystems, drugs, Ag–FSE_NS preparation, in vitro antibacterial activity, pure Ag–FSE, Ag–FSE_NS1 particles, optimised Ag–FSE_NS1, zeta potential, enhanced antibacterial efficacy, antibacterials 相似文献
4.
MK Bolla GJ Miller DM Yellon A Evans G Luc JP Cambou D Arveiler F Cambien DS Latchman SE Humphries IN Day 《Canadian Metallurgical Quarterly》1998,13(4):227-235
In 12 depressed inpatients referred for bilateral electroconvulsive therapy (ECT), each patient was titrated at the first treatment session by using an ascending method-of-limits procedure with a step-wise increase in pulse frequency (frequency titration) or train duration (duration titration). At the second treatment session, seizure threshold was redetermined by using the method (frequency or duration titration) not used at the first treatment. Frequency or duration was maintained at the lowest level when the other parameter was titrated. Seizure threshold was significantly lower with duration titration (mean, 90 mC; SD, 27.3) than frequency titration (mean, 114 mC; SD, 35.6; p = 0.03). On average, patients in the duration-titration group required 1.2 (SD, 0.6) subconvulsive stimulations before a seizure was elicited, and patients in the frequency-titration group required 1.7 (SD, 0.9) subconvulsive stimulations before a seizure was elicited, a nonsignificant difference. These findings suggest that to elicit a seizure during ECT, increasing train duration may be slightly more efficient than increasing frequency. Basic and other clinical research findings indicate that increasing pulse width may be an inefficient way to elicit a seizure. Therefore the following sequence in the determination of seizure threshold is worth considering when using dose-titration or related techniques: the train duration should be increased first before increasing pulse frequency, and the decision to increase pulse width should be reserved for patients who do not seize at the maximal duration and frequency settings. Further empiric research is needed to establish the utility of this approach. 相似文献
5.
Concepción?CollarEmail author Clara?Bollaín 《European Food Research and Technology》2004,218(2):139-146
The effects of microbial transglutaminase (TGM) on the viscoelastic profile of wheat flour doughs when added singly and in combination with hydrocolloids—hydroxypropylmethylcellulose (HPMC) and a high ester pectin (GENU pectin type BIG, or BIG)—, amylolytic (-amylase) and non amylolytic enzymes (xylanase) and an emulsifier [diacetyl tartaric acid ester of mono-diglycerides (DATEM)] have been investigated by applying response surface analysis to a Draper-Lin small composite design of formulated dough samples. In spite of the major effects on mixing, textural, extensional and viscometric parameters, which were provided by hydrocolloid/surfactant combinations, incorporation of TGM into dough formulas improved some viscoelastic properties. TGM, when added to DATEM and/or HPMC-containing doughs, induced synergistic effects on mixing parameters, resulting in increased water absorption, development time and stability. Highly cohesive doughs with improved water holding capacity and gluten strength during mixing and fermentation, and suitable pasting behaviour during cooking were achieved using TGM/BIG/DATEM mixtures, mainly associated with suitable interactions of the pairs TGM/DATEM and DATEM/BIG. 相似文献
6.
JP Vuillez E Levrot M Mousseau PD Buffaz M Bolla R Payan M Comet R Schaerer 《Canadian Metallurgical Quarterly》1997,84(11):1033-1042
Immunoscintigraphy using indium-111-labeled OC125 monoclonal antibody F(ab')2 fragments is a technic complementary of morphological imaging (i.e. ultrasonography and computed tomography). It allows early detection of recurrences of ovarian carcinomas. We performed immunoscintigraphy 30 times in 26 patients who previously underwent radical treatment for ovarian carcinoma, and were suspected to have a recurrence. Our purposes were appreciation of diagnostic accuracy of the method, and above all its impact on clinical decisions and evolution of the patients. There were, after reevaluation of the results, 18 true positives, 7 true negatives, 3 false negatives and 2 false positive cases (sensitivity 85.7%, specificity 77.8%). Bayesian analysis showed positive and negative predictive values of 86% and 87% when probability of recurrence a priori was 50%, and 80% and 58% when probability of recurrence a priori was 70%. The result of immunoscintigraphy contributed to clinical decisions in 24 cases out of 30, and led to a correct decision for the patient in 21 cases. Conversely, for the 6 cases in which the result has not been considered, to take this result into account would have been beneficial in 4 cases, but harmful in 2. Finally, survival tended to be longer when immunoscintigraphy was negative, which could be associated with a better prognosis. We conclude that OC125-immunoscintigraphy may be useful for ovarian carcinoma follow-up and may contribute to a better therapeutic strategy. 相似文献
7.
The purpose of this study is to analyze the impact of velocity slip, chemical reaction, and suction/injection on two-dimensional mass transfer effects on unsteady MHD flow over a stretching surface in the presence of thermal radiation and viscous dissipation. The governing time-dependent nonlinear partial differential equations are transformed into nonlinear ordinary differential equations by using similarity transformations. The converted equations are solved using the numerical technique with the help of Keller-Box method. The effect of nondimensional variables is studied and graphically illustrated on velocity, temperature, concentration, friction factor, Nusselt number, and Sherwood number. Concentration and temperature profiles are enhanced and the contrasting pattern for velocity profiles as increasing the velocity slip and magnetic parameter. The concentration profile is diminished as the Schmidt number (Sc) and chemical reaction (Cr) increase. The concentration, velocity, and temperature profiles display a reversal pattern, as the suction and unsteady parameter (A) increase. The findings of this study are very well-acknowledged with current research. 相似文献
8.
M Bolla X Artignan E Chirpaz J Balosso JL Descotes 《Canadian Metallurgical Quarterly》1998,2(6):783-786
In locally advanced prostate cancer three clinical randomized trials have shown that external irradiation combined with LHRH analogue with or without antiandrogen improved survival: disease-free survival, local recurrence-free survival, metastasis-free survival (P < 0.001). EORTC trial 22863 alone has shown a significant improvement of overall survival (P = 0.001), with an LHRH analogue (goserilin acetate, zoladex) started the first day of irradiation and followed every 4 weeks for 3 years; for RTOG trial 85-31 the same LHRH analogue started during the last week of irradiation and given until relapse increases survival of patients with poor differentiated tumours with gleason score ranging from 8 to 10 (P = 0.03). In locally confined prostate carcinoma randomized trials are ongoing to assess the impact of conventional irradiation or three dimensional conformal radiotherapy with or without adjuvant hormonotherapy. 相似文献
9.
10.
Damjanovic D. Bolla H.K. Singh R. Poole K.F. Senter H.F. Narayan J. 《Semiconductor Manufacturing, IEEE Transactions on》2005,18(1):55-62
We show that UV/VUV-enhanced rapid thermal processing (RTP) in combination with single-wafer processing using a single tool for the fabrication of metal gate/high-/spl kappa/ dielectric gate stacks not only improves overall device performance, but also leads to a significant reduction in process variation at the front end of the CMOS process flow for the sub-90-nm technology node. The gate stacks were fabricated under various UV/VUV conditions. Gate stacks processed under UV/VUV radiation during all processing steps displayed low leakage currents of the order of 10/sup -11/ A/cm/sup 2/. It is shown that the Al-Al/sub 2/O/sub 3/-Si gate stacks processed under UV/VUV conditions also display the lowest variations both in mean leakage current and mean capacitance, as compared to devices where UV/VUV was not used for all the processing steps. Therefore, it can be see that reliance on successive corrective iterations common to automatic process control or standard design simulation can be reduced significantly. As a result, UV/VUV-enhanced RTP has the potential to reduce the effect of process variations on overall device performance, thereby making the overall process more cost effective and time efficient and therefore improving yield and device reliability. 相似文献