首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   141篇
  免费   8篇
  国内免费   2篇
电工技术   8篇
化学工业   20篇
金属工艺   1篇
机械仪表   1篇
建筑科学   8篇
能源动力   22篇
轻工业   13篇
石油天然气   1篇
无线电   24篇
一般工业技术   29篇
冶金工业   1篇
自动化技术   23篇
  2023年   3篇
  2022年   1篇
  2021年   6篇
  2020年   5篇
  2019年   7篇
  2018年   2篇
  2017年   16篇
  2016年   7篇
  2015年   2篇
  2014年   12篇
  2013年   14篇
  2012年   15篇
  2011年   18篇
  2010年   7篇
  2009年   5篇
  2008年   9篇
  2007年   3篇
  2006年   6篇
  2005年   2篇
  2003年   2篇
  2002年   4篇
  1996年   1篇
  1993年   1篇
  1989年   1篇
  1974年   1篇
  1973年   1篇
排序方式: 共有151条查询结果,搜索用时 31 毫秒
1.
2.
This research project sought to design and implement a computerized clinical decision support system (CDSS) that was able to identify patients who were at risk of pulmonary embolism (PE) and deep vein thrombosis (DVT), as well as produce reminders for prophylactic action for these diseases. The main purpose of the CDSS was to attempt to reduce the morbidity and mortality caused by embolism and thrombosis in patients admitted to hospitals. After implementation of this system in one of the large educational hospitals of Iran, a standard questionnaire was used, and interviews were conducted with physicians and nurses to evaluate the performance of the designed system for reducing the incidence of pulmonary embolism and thrombosis. From physicians and nurses’ point of view, a system which assists the medical staff in making better decisions regarding patient care, and also reminds pulmonary embolism and thrombosis preventive procedures with timely warnings, can influence patient care quality improvement and lead to the improved performance of the medical staff in preventing the incidence of pulmonary embolism and thrombosis.  相似文献   
3.
4.
5.
Piezoelectric materials have dominated the ultrasonic transducer technology. Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as an alternative technology offering advantages such as wide bandwidth, ease of fabricating large arrays, and potential for integration with electronics. The aim of this paper is to demonstrate the viability of CMUTs for ultrasound imaging. We present the first pulse-echo phased array B-scan sector images using a 128-element, one-dimensional (1-D) linear CMUT array. We fabricated 64- and 128-element 1-D CMUT arrays with 100% yield and uniform element response across the arrays. These arrays have been operated in immersion with no failure or degradation in performance over the time. For imaging experiments, we built a resolution test phantom roughly mimicking the attenuation properties of soft tissue. We used a PC-based experimental system, including custom-designed electronic circuits to acquire the complete set of 128 x 128 RF A-scans from all transmit-receive element combinations. We obtained the pulse-echo frequency response by analyzing the echo signals from wire targets. These echo signals presented an 80% fractional bandwidth around 3 MHz, including the effect of attenuation in the propagating medium. We reconstructed the B-scan images with a sector angle of 90 degrees and an image depth of 210 mm through offline processing by using RF beamforming and synthetic phased array approaches. The measured 6-dB lateral and axial resolutions at 135 mm depth were 0.0144 radians and 0.3 mm, respectively. The electronic noise floor of the image was more than 50 dB below the maximum mainlobe magnitude. We also performed preliminary investigations on the effects of crosstalk among array elements on the image quality. In the near field, some artifacts were observable extending out from the array to a depth of 2 cm. A tail also was observed in the point spread function (PSF) in the axial direction, indicating the existence of crosstalk. The relative amplitude of this tail with respect to the mainlobe was less than -20 dB.  相似文献   
6.
Transport phenomena within PEM fuel cells are investigated and a comprehensive analytical solution is presented. The methodology couples the transport within the fuel cell supply channels and the substrate which is composed of five different layers. The layers are all treated as macroscopically homogeneous porous media with uniform morphological properties such as porosity and permeability. The locally volume-averaged equations are employed to solve for transport through the porous layers. The problem encompasses complex interfacial transport phenomena involving several porous–porous as well as porous–fluid interfaces. Chemical reactions within the catalyst layers are also included. The method of matched asymptotic expansions is employed to solve for the flow field and species concentration distributions. Throughout the analysis, the choice of the gauge parameters involved in the perturbation solutions for velocity and concentration is found to be inherently tied to the physics of the problem and therefore an important physical metric. The analytical solution is found to be in excellent agreement with prior computational simulations. The analytical results are used to investigate several aspects of transport phenomena and their substantial role in PEM fuel cell operation. The solution presented in this work provides the first comprehensive analytical solution representing fuel cell transport phenomena.  相似文献   
7.
Papermaking sludge (PS), a waste residue from the pulp and paper processing, has brought great pressure on the environment because of large quantities that are produced in paper mills. This work was carried out to explore the possibility of making PS/cement composite products using solid waste of PS. Boards measuring 350 × 270 × 12 mm3 were manufactured using PS contents of 40, 50, and 60 wt%, adhesive dosages of 0, 10, and 15 wt%, and 0 and 5 wt% of calcium chloride as an accelerator. At least three replications were fabricated for each treatment, and some mechanical and physical properties of the boards were evaluated. Test results showed that the bending and internal strengths of the specimens decreased with an increase in the PS content, and the maximum values were obtained at PS loading of 40 wt%. The negative influence of PS content on the mechanical properties can be explained by the reduced bonding ability because of weaker PS compared with cement. Screw withdrawal values were up to 22.7 kPa. Water absorption and thickness swelling of cement mortar considerably increased with increased content of PS, with a corresponding reduction of bulk density. In general, all properties of the boards were improved when the adhesive and calcium chloride contents were increased. The results showed that an increase in board density improved the mechanical and physical properties. Finally, results showed that PS has good potential for recycling and utilization in developing value‐added building components. POLYM. ENG. SCI., 2013. © 2012 Society of Plastics Engineers  相似文献   
8.
Polymerase chain reaction (PCR) is widely used in biochemical analysis to amplify DNA and RNA in vitro. The PCR process is highly temperature sensitive, and thermal management has an important role in PCR operation in reaching the required temperature set points at each step of the process. The goal of this research is to achieve a thermal technique to rapidly increase the heating/cooling thermal cycling speed while maintaining a uniform temperature distribution throughout the substrate containing the aqueous nucleic acid sample. In this work, an innovative microfluidic PCR thermal cycler, which utilizes a properly arranged configuration filled with a porous medium, is investigated. Various effective parameters that are relevant in optimizing this flexible heat exchanger are investigated such as heat exchanger geometry, flow rate, conductive plate, the porous matrix material, and utilization of thermal grease. An optimized case is established based on the effects of the cited parameters on the temperature distribution and the required power for circulating the fluid in the heat exchanger. The results indicate that the heating/cooling temperature ramp of the proposed PCR heat exchanger is considerably higher (150.82 °C/s) than those in the literature. In addition, the proposed PCR offers a very uniform temperature in the substrate while utilizing a low power.  相似文献   
9.
Heat transfer enhancement in a two-dimensional enclosure utilizing nanofluids is investigated for various pertinent parameters. A model is developed to analyze heat transfer performance of nanofluids inside an enclosure taking into account the solid particle dispersion. The transport equations are solved numerically using the finite-volume approach along with the alternating direct implicit procedure. Comparisons with previously published work on the basis of special cases are performed and found to be in excellent agreement. The effect of suspended ultrafine metallic nanoparticles on the fluid flow and heat transfer processes within the enclosure is analyzed and effective thermal conductivity enhancement maps are developed for various controlling parameters. In addition, an analysis of variants based on the thermophysical properties of nanofluid is developed and presented. It is shown that the variances within different models have substantial effects on the results. Finally, a heat transfer correlation of the average Nusselt number for various Grashof numbers and volume fractions is presented.  相似文献   
10.
Rapid and sensitive detection of serum tumor biomarkers are needed to monitor cancer patients for disease progression. Highly sensitive piezoelectric microcantilever sensors (PEMS) offer an attractive tool for biomarker detection; however, their utility in the complex environment encountered in serum has yet to be determined. As a proof of concept, we have functionalized PEMS with antibodies that specifically bind to HER2, a biomarker (antigen) that is commonly overexpressed in the blood of breast cancer patients. The function and sensitivity of these anti-HER2 PEMS biosensors was initially assessed using recombinant HER2 spiked into human serum. Their ability to detect native HER2 present in the serum of breast cancer patients was then determined. We have found that the anti-HER2 PEMS were able to accurately detect both recombinant and naturally occurring HER2 at clinically relevant levels (>2 ng/mL). This indicates that PEMS-based biosensors provide a potentially effective tool for biomarker detection.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号