排序方式: 共有18条查询结果,搜索用时 15 毫秒
1.
Predrag Osmokrovic Boris Loncar Srboljub Stankovic Aleksandra Vasic 《Microelectronics Reliability》2002,42(12):1959-1966
The aim of this work is examining the influence of the number of the activation––over-voltage pulses to the aging of over-voltage protection elements. Both non-linear (gas-filled surge arresters (GFSA), varistors, over-voltage diodes) and linear (capacitors––constituents of filters) over-voltage protection elements were tested. The instruments employed allow reliable measurements, 1000 consecutive activation were tested. The double-exponential current pulse (amplitude I1max=13 A, I2max=16 A, rise time T1=8 μs, fall time T2=20 μs) for non-linear elements and a double-exponential over-voltage pulse (rise time T1=1.2 μs, fall time T2=50 μs) of the amplitude U1max=320 V, U2max=480 V and U3max=640 V for capacitors were used. The experimental results show that the over-voltage diodes are the most reliable elements in view of characteristic modifications that are consequence of aging. However, it was observed that varistors, GFSA and capacitors undergo noticeable changes in characteristics. 相似文献
2.
Scherer A. Painter O. Vuckovic J. Loncar M. Yoshie T. 《Nanotechnology, IEEE Transactions on》2002,1(1):4-11
By using the photonic crystals, we can confine, guide, and emit light efficiently. By precise control over the geometry and three-dimensional design, it is possible to obtain high quality optical devices with extremely small dimensions. Here we describe examples of high-Q optical nanocavities, photonic crystal waveguides, and surface plasmon enhanced light-emitting diode (LEDs) 相似文献
3.
Optimization of the Q factor in photonic crystal microcavities 总被引:2,自引:0,他引:2
Vuckovic J. Loncar M. Mabuchi H. Scherer A. 《Quantum Electronics, IEEE Journal of》2002,38(7):850-856
We express the quality factor of a mode in terms of the Fourier transforms of its field components and prove that the reduction in radiation loss can be achieved by suppressing the mode's wavevector components within the light cone. Although this is intuitively clear, our analytical proof gives us insight into how to achieve the Q factor optimization, without the mode delocalization. We focus on the dipole defect mode in free-standing membranes and achieve Q > 104, while preserving the mode volume of the order of one half of the cubic wavelength of light in the material. The derived expressions and conclusions can be used in the optimization of the Q factor for any type of defect in planar photonic crystals 相似文献
4.
Hausmann BJ Shields B Quan Q Maletinsky P McCutcheon M Choy JT Babinec TM Kubanek A Yacoby A Lukin MD Loncar M 《Nano letters》2012,12(3):1578-1582
We demonstrate an integrated nanophotonic network in diamond, consisting of a ring resonator coupled to an optical waveguide with grating in- and outcouplers. Using a nitrogen-vacancy color center embedded inside the ring resonator as a source of photons, single photon generation and routing at room temperature is observed. Furthermore, we observe a large overall photon extraction efficiency (10%) and high quality factors of ring resonators (3200 for waveguide-coupled system and 12,600 for a bare ring). 相似文献
5.
In this paper, a set of formulae for the temporal spontaneous baroreceptor reflex (sBRR) sequence parameters in isodistributional (ID) surrogate data is derived. This is facilitated by representing successive positive or negative amplitude changes as a Markov chain model. The obtained analytical tool measures the effect of random fluctuations on the overall number of sequences, estimated from the original biomedical time series. The formulae are tested using ID surrogates of systolic blood pressure and pulse-interval signals recorded from 13 healthy male Wistar rats at baseline conditions. 相似文献
6.
Z Hrgovi? M Kaufmann J Loncar A Salihagi? U Langenbeck 《Canadian Metallurgical Quarterly》1995,49(1-2):13-17
Congenital genetic disturbances in the genes BRCA1 and BRCA2 could lead to the forming of mamacarcinoma and ovarian carcinomas. The probability of illness is by an existing gene defect very high, and mostly young women are already affected. A direct anamnestic identification of high risk person with a following proof of gene mutations could help the patient. The way of the clinical-consultation which is recommending the BRCA1-BRCA2-test in reasons for an early recognition diagnosis is at the moment subject in clinical and scientific research. 相似文献
7.
Maletinsky P Hong S Grinolds MS Hausmann B Lukin MD Walsworth RL Loncar M Yacoby A 《Nature nanotechnology》2012,7(5):320-324
The nitrogen-vacancy defect centre in diamond has potential applications in nanoscale electric and magnetic-field sensing, single-photon microscopy, quantum information processing and bioimaging. These applications rely on the ability to position a single nitrogen-vacancy centre within a few nanometres of a sample, and then scan it across the sample surface, while preserving the centre's spin coherence and readout fidelity. However, existing scanning techniques, which use a single diamond nanocrystal grafted onto the tip of a scanning probe microscope, suffer from short spin coherence times due to poor crystal quality, and from inefficient far-field collection of the fluorescence from the nitrogen-vacancy centre. Here, we demonstrate a robust method for scanning a single nitrogen-vacancy centre within tens of nanometres from a sample surface that addresses both of these concerns. This is achieved by positioning a single nitrogen-vacancy centre at the end of a high-purity diamond nanopillar, which we use as the tip of an atomic force microscope. Our approach ensures long nitrogen-vacancy spin coherence times (~75?μs), enhanced nitrogen-vacancy collection efficiencies due to waveguiding, and mechanical robustness of the device (several weeks of scanning time). We are able to image magnetic domains with widths of 25?nm, and demonstrate a magnetic field sensitivity of 56?nT Hz(-1/2) at a frequency of 33?kHz, which is unprecedented for scanning nitrogen-vacancy centres. 相似文献
8.
Goran Loncar Daniel Omersa Natasa Cvetinovic Aleksandra Arandjelovic Mitja Lainscak 《International journal of molecular sciences》2014,15(12):23878-23896
Biomarkers are objective tools with an important role for diagnosis, prognosis and therapy optimization in patients with heart failure (HF). To date, natriuretic peptides are closest to optimal biomarker standards for clinical implications in HF. Therefore, the efforts to identify and test new biomarkers in HF are reasonable and justified. Along the natural history of HF, cardiac cachexia may develop, and once at this stage, patient performance and prognosis is particularly poor. For these reasons, numerous biomarkers reflecting hormonal, inflammatory and oxidative stress pathways have been investigated, but only a few convey relevant information. The complex pathophysiology of HF appears far too complex to be embraced by a single biomarker; thus, a combined approach appears reasonable. With these considerations, we have reviewed the recent developments in the field to highlight key candidates with diagnostic, prognostic and therapy optimization properties, either alone or in combination. 相似文献
9.
Surface plasmon enhanced light-emitting diode 总被引:4,自引:0,他引:4
A method for enhancing the emission properties of light-emitting diodes, by coupling to surface plasmons, is analyzed both theoretically and experimentally. The analyzed structure consists of a semiconductor emitter layer thinner than λ/2 sandwiched between two metal films. If a periodic pattern is defined in the top semitransparent metal layer by lithography, it is possible to efficiently couple out the light emitted from the semiconductor and to simultaneously enhance the spontaneous emission rate. For the analyzed designs, we theoretically estimate extraction efficiencies as high as 37% and Purcell factors of up to 4.5. We have experimentally measured photoluminescence intensities of up to 46 times higher in fabricated structures compared to unprocessed wafers. The increased light emission is due to an increase in the efficiency and an increase in the pumping intensity resulting from trapping of pump photons within the microcavity 相似文献
10.