A micropower detector chip integrated with CMOS technology has been developed for a hand-held heart rate monitoring instrument mainly used by professional athletes and others who exercise seriously to increase their endurance and overall performance. The chip uses linear bandpass filtering and threshold detection and is implemented with analog switched-capacitor (SC) and digital techniques. The bandpass filter transfer function is derived from the spectral contents of noisy ECG signals. The layout was designed in full custom style in order to minimize the silicon area. The chip achieves a detection rate of 90% with a simulated ECG signal corrupted with Gaussian noise (signal-to-noise ratio = 5) in the heart rate range 60-200 1/min with a total current consumption of less than 30µA from a 3-V supply. The detection rate is 96.9% for a noisy signal obtained from the MIT-BIH arrhythmia database.  相似文献   
2.
The design, test methods, and results of an ambulatory QRS detector are presented. The device is intended for the accurate measurement of heart rate variability (HRV) and reliable QRS detection in both ambulatory and clinical use. The aim of the design work was to achieve high QRS detection performance in terms of timing accuracy and reliability, without compromising the size and power consumption of the device. The complete monitor system consists of a host computer and the detector unit. The detector device is constructed of a commonly available digital signal processing (DSP) microprocessor and other components. The QRS detection algorithm uses optimized prefiltering in conjunction with a matched filter and dual edge threshold detection. The purpose of the prefiltering is to attenuate various noise components in order to achieve improved detection reliability. The matched filter further improves signal-to-noise ratio (SNR) and symmetries the QRS complex for the threshold detection, which is essential in order to achieve the desired performance. The decision for detection is made in real-time and no search-back method is employed. The host computer is used to configure the detector unit, which includes the setting of the matched filter impulse response, and in the retrieval and postprocessing of the measurement results. The QRS detection timing accuracy and detection reliability of the detector system was tested with an artificially generated electrocardiogram (EGG) signal corrupted with various noise types and a timing standard deviation of less than 1 ms was achieved with most noise types and levels similar to those encountered in real measurements. A QRS detection error rate (ER) of 0.1 and 2.2% was achieved with records 103 and 105 from the MIT-BIH Arrhythmia database, respectively  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号