The use of reinforced polymers as cores of transmission cables can provide significant advantages compared to traditional steel cores, such as high tensile strength, low thermal expansion coefficients, and low sag between towers. This work evaluates the applicability of pultruded rods consisting of phenol–formaldehyde resin reinforced with carbon fiber as cores of transmission cables. In this work, the samples were divided into three groups: samples without aging, and samples UV and thermally aged. At first, a dynamic mechanical analysis was performed on samples without aging in order to determine the viscoelastic properties of the material based on the application to see if it would be compatible. In addition to this test, tensile strength and Young's modulus were determined for the three groups. Since the composite cores are susceptible to creep in high temperatures, the applicability must be below the glass transition temperature. Regarding creep behavior, results showed that at a reference temperature of 100 °C, the stress level necessary to cause failure after 50 years was 89% of the ultimate strength. The results of tensile tests were favorable for application of the pultruded system as transmission cables cores and the accelerated aging affected positively in these composites.
Breast cancer (BC) is a malignant neoplasia with the highest incidence and mortality rates in women worldwide. Currently, therapies include surgery, radiotherapy, and chemotherapy, including targeted therapies in some cases. However, treatments are often associated with serious adverse effects. Looking for new options in BC treatment, we evaluated the therapeutic potential of cold atmospheric plasma (CAP) in two cell lines (MCF7 and HCC1806) with distinct histological features. Apoptosis seemed to be the most prevalent type of death, as corroborated by several biochemical features, including phosphatidylserine exposure, the disruption of mitochondrial membrane potential, an increase in BAX/BCL2 ratio and procaspase 3 loss. Moreover, the accumulation of cells in the G2/M phase of the cell cycle points to the loss of replication ability and decreased survival. Despite reported toxic concentrations of peroxides in culture media exposed to plasma, intracellular peroxide concentration was overall decreased accompanying a reduction in GSH levels shortly after plasma exposure in both cell lines. In HCC1806, elevated nitric oxide (NO) concentration accompanied by reduced superoxide levels suggests that these cells are capable of converting plasma-derived nitrites into NO that competes with superoxide dismutase (SOD) for superoxide to form peroxinitrite. The concomitant inhibition of the antioxidative activity of cells during CAP treatment, particularly the inhibition of cytochrome c oxidase with sodium azide, synergistically increased plasma toxicity. Thus, this in vitro research enlightens the therapeutic potential of CAP in the treatment of breast cancer, elucidating its possible mechanisms of action. 相似文献
The circadian clock (CC) is a daily system that regulates the oscillations of physiological processes and can respond to the external environment in order to maintain internal homeostasis. For the functioning of the CC, the clock genes (CG) act in different metabolic pathways through the clock-controlled genes (CCG), providing cellular regulation. The CC’s interruption can result in the development of different diseases, such as neurodegenerative and metabolic disorders, as well as cancer. Leukemias correspond to a group of malignancies of the blood and bone marrow that occur when alterations in normal cellular regulatory processes cause the uncontrolled proliferation of hematopoietic stem cells. This review aimed to associate a deregulated CC with the manifestation of leukemia, looking for possible pathways involving CG and their possible role as leukemic biomarkers. 相似文献
X-ray photoelectron spectroscopy (XPS) applied to the study of fluorinated polymer surfaces presents several problems related both to peak assignment and to degradation. In this work, we analyse extensively the question of XPS peak assignments in this kind of surfaces. We conclude that in this kind of surfaces using binding energy differences between fluorine and carbon is better than using absolute binding energies. Also a useful relation between fluorine photoelectron energy vs. polymer composition expressed through the atomic ratio fluorine/carbon (F/C) was found. A protocol for data treatment is proposed and applied to a XPS study of the degradation induced by X-ray on high-density polyethylene surfaces modified by direct fluorination. Results obtained for the degradation, namely the atomic ratio F/C obtained by two different methods, combined with angle resolved X-ray photoelectron spectroscopy (ARXPS) were used to study the fluorine concentration profile in depth, producing self-consistent results. 相似文献
This study evaluated the effect of chlorhexidine (CLX) in cavities prepared with either ultrasound-mounted CVDentUS diamond tips or conventional diamond burs on dentin bond strength after 24 h and 180 days. Forty-eight dentin surfaces from sound third molars were flattened and divided into four groups (n = 12), according to the type of cavity preparation (CVDentUS ultrasound tip or conventional diamond) and with or without 2% CLX (Consepsis) treatment. After application of the adhesive system (Clearfil SE Bond), microhybrid composite resin blocks (Charisma) were made on the dentin surface in increments. After 24 h, the specimens were sectioned into stick-shaped samples with an adhesive interface of approximately 1 mm2. From each tooth, half of the sticks were evaluated after 24 h of storage in distilled water and the other half after 180 days, using a universal testing machine. Three-way analysis of variance showed no significant triple interactions (p = 0.722) or double interactions between factors. Higher bond strength values were observed with the use of ultrasonic tips (p = 0.019), irrespective of whether or not CLX was applied in either time period. No difference in bond strength values was observed in terms of CLX application (p = 0.581). No significant difference in bond strength values was shown after storage for 24 h or 180 days (p = 0.302). In conclusion, the ultrasonic tips promoted greater bond strength to dentin, irrespective of whether or not CLX was applied, and storage time. 相似文献
The aim of this study was to evaluate over time the bond strength of dual-cure and self-adhesive resin cements used for bonding fiberglass posts following irrigation with different solutions. Ninety roots from single-rooted premolars were selected and divided into 6 groups (n = 15) according to the resin cement, dual-cure or self-adhesive (RelyX ARC and RelyX U100) or the endodontic irrigant used (2% chlorhexidine digluconate - CH, 1% sodium hypochlorite - SH and deionized distilled water – control). Following post cementation, the roots were cross-sectioned in order to obtain two slices from each root third (cervical, mid and apical). The specimens were stored for 7 or 180 days in water and the push-out bond strength test applied. The data was analyzed using three-way ANOVA and Tukey Kramer. The interaction endodontic irrigants-resin cement vs. storage time was significant (p = 0.008), where 7 days of storage induced no difference between the groups, however, after 180 days, the groups for which CH or SH combined with RelyX U100 were used showed higher bond strength values than RelyX ARC, regardless of the irrigant solution. There was no difference between the use of RelyX ARC after 7 and 180 days of storage. For Rely X U100 180 days of storage increased the push-out bond strength when either CH or SH was used. The dual-cure and self-adhesive resin cements associated with CH or SH demonstrated similar immediate bond strength performance. The self-adhesive cement, however, showed improved bond strength over time when either irrigant was used. 相似文献
Two different carbon/epoxy prepreg materials were characterized and compared using thermal (DSC, TGA, and DMA) and rheological analyses. A prepreg system (carbon fiber preimpregnated with epoxy resin F584) that is currently used in the commercial airplane industry was compared with a prepreg system that is a prospective candidate for the same applications (carbon fiber prepreg/epoxy resin 8552). The differences in the curing kinetics mechanisms of both prepreg systems were identified through the DSC, TGA, DMA, and rheological analyses. Based on these thermal analysis techniques, it was verified that the curing of both epoxy resin systems follow a cure kinetic of n order. Even though their reaction heats were found to be slightly different, the kinetics of these systems were nevertheless very similar. The activation energies for both prepreg systems were determined by DSC analysis, using Arrhenius's method, and were found to be quite similar. DMA measurements of the cured prepregs demonstrated that they exhibited similar degrees of cure and different glass transition temperatures. Furthermore, the use of the rheological analysis revealed small differences in the gel temperatures of the two prepreg systems that were examined. 相似文献