首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   49篇
  免费   1篇
化学工业   1篇
机械仪表   29篇
能源动力   1篇
无线电   4篇
一般工业技术   8篇
冶金工业   6篇
原子能技术   1篇
  2015年   1篇
  2014年   1篇
  2013年   1篇
  2012年   3篇
  2009年   1篇
  2007年   1篇
  2005年   1篇
  2004年   6篇
  2001年   3篇
  2000年   3篇
  1999年   1篇
  1998年   1篇
  1997年   4篇
  1996年   6篇
  1994年   2篇
  1992年   1篇
  1991年   1篇
  1990年   2篇
  1988年   1篇
  1987年   3篇
  1986年   3篇
  1985年   3篇
  1984年   1篇
排序方式: 共有50条查询结果,搜索用时 15 毫秒
1.
Oho E  Suzuki K 《Scanning》2012,34(1):43-50
Quality of an SEM image is strongly influenced by the extent of noise. As a well-known method in the field of SEM, the covariance is applied to measure the signal-to-noise ratio (SNR). This method has potential ability for highly accurate measurement of the SNR, which is hardly known until now. If the precautions discussed in this article are adopted, that method can demonstrate its real ability. These precautions are strongly related to "proper acquisition of two images with the identical view," "alignment of an aperture diaphragm," "reduction of charging phenomena," "elimination of particular noises," and "accurate focusing," As necessary, characteristics in SEM signal and noise are investigated from a few standpoints. When using the maximum performance of this measurement, SNR of many SEM images obtained in a variety of the SEM operating conditions and specimens can be measured accurately.  相似文献   
2.
E. Oho  K. Kanaya 《Scanning》1990,12(3):141-146
An on-line digital image processing system provides several useful functions to SEM users. It is especially convenient for general SEM image storing and filing, preferable to conventional methods using video monitor, camera, and film. When equipped with state-of-the-art magneto-optical disk unit (external memory) and a video copy processor for printout of a digital SEM image, its usefulness is enhanced. In order to validate this useful function, we compare a modern on-line digital image recording system with a conventional one, from the viewpoint of the general SEM user.  相似文献   
3.
Based on the previous success of adding ultra-fine carbon–PVA (polyvinyl alcohol) colloid solution to restore performance of weak batteries, a large scale test programme of practical batteries including those used in forklift, golf cart, taxi cab, truck and bus applications from 150 companies was carried out. More than 95% of the tested batteries exhibited excellent recovery in performance parameters including the specific gravity (S.G.), voltage and operation time (Ah capacity). The work reported here includes basic research studies to understand better the beneficial action of the carbon–PVA colloid additive.  相似文献   
4.
5.
Oho E  Miyamoto M 《Scanning》2004,26(5):250-255
A scanning electron microscope (SEM) system equipped with a motor drive specimen stage fully controlled with a personal computer (PC) has been utilized for obtaining ultralow magnification SEM images. This modem motor drive stage works as a mechanical scanning device. To produce ultra-low magnification SEM images, we use a successful combination of the mechanical scanning, electronic scanning, and digital image processing techniques. This new method is extremely labor and time saving for ultra-low magnification and wide-area observation. The option of ultra-low magnification observation (while maintaining the original SEM functions and performance) is important during a scanning electron microscopy session.  相似文献   
6.
7.
A comparison of two methods: analytical and calculation on an estimation of dietary intakes of nitrate and nitrite from six different types of general hospital diets was studied. Studies were performed in the winter season of 1996-1997. It was found that the mean daily intake of nitrates was 85 mg per person in the analytical method, and 65 mg per person in the calculated method. The estimation of average dietary intakes of nitrite was adequate: 1.67 mg per person (the analytical method) and 1.18 mg per person (the calculated method). The main source of nitrates were vegetables, whereas the main source of nitrites was meat and meat-containing products. We suggest that the different methodologies, analytical and calculation methods, for measuring dietary intakes of nitrate and nitrite from diets make it possible to make direct comparisons of intakes.  相似文献   
8.
BACKGROUND/AIMS: The aim of this prospective study was to examine the association of portal-hypertensive gastropathy and fundal varices in patients with cirrhosis. METHODS: We carried out an endoscopic observation in 476 patients with cirrhosis (study 1), including 62 patients undergoing endoscopic obliteration of esophageal varices (study 2). In study 1, patients were classified into five subgroups: no esophagofundal varices (n=119), small esophagofundal varices (n=127), dominant esophageal varices (n=177), dominant fundal varices (n=27), and large esophagofundal varices (n=26). The severity of liver dysfunction was assessed by Pugh-Child classification: class A (n=222), class B (n=200), and class C (n=54). In study 2, two groups, poorly developed fundal varices (n=50) and well developed fundal (n=12), were distinguished and the follow-up endoscopic examinations were performed on the basis of 3-month intervals for 2 years. In each study, the severity of portal-hypertensive gastropathy was scored: 0 (absent), 1 (mild), 2 (severe), and 3 (bleeding). RESULTS: Study 1: One-way ANOVA showed that both variceal pattern and Pugh-Child class significantly influenced portal-hypertensive gastropathy score. However, two-way ANOVA indicated that variceal pattern was the only significant variable. Portal-hypertensive gastropathy score was significantly higher in patients with dominant esophageal varices than in either patients with no esophagofundal varices or patients with small esophagofundal varices. In contrast, portal-hypertensive gastropathy score in patients with dominant fundal varices was similar to that in patients with no esophagofundal varices and was significantly lower compared with that in patients with dominant esophageal varices. Furthermore, portal-hypertensive gastropathy score was significantly lower in patients with large esophagofundal varices than in patients with dominant esophageal varices. Study 2: After the obliteration of esophageal varices, portal-hypertensive gastropathy score in patients with poorly developed fundal varices became significantly higher at 3-, 6-, 9-months while it was not modified in patients with well developed fundal varices during the follow-up period. Furthermore, the integrated incremental change in portal-hypertensive gastropathy score during the first 1-year follow-up period was significantly lower in patients with well developed fundal varices than in patients with poorly developed fundal varices. CONCLUSIONS: These results indicate that both spontaneous and obliteration-induced portal-hypertensive gastropathy lesions develop less in patients with cirrhosis and fundal varices.  相似文献   
9.
An approach to multiplex in-cylinder pressure measurement that utilizes a single-mode optical fiber with specific refractive-index composition has been proposed. The sensing fiber has been designed to show a certain amount of optical power loss with a small change in the fiber-local-bend radius. Along with pressure-transferring diaphragms the sensing fiber was embedded into the head gasket of a four-cylinder gasoline engine. The internal-pressure change in each combustion chamber was detected on the basis of bending power loss in the fiber. Combustion pressure peaks for each cylinder were clearly observed.  相似文献   
10.
Oho S  Sonobe H  Kajioka H 《Applied optics》1997,36(10):2222-2228
The signal distortion that is due to Fresnel reflection in open-loop fiber-optic gyroscopes was theoretically analyzed to determine the relationship between the reflection ratio and the scale factor error of the gyroscopes. The analysis showed that the in-phase component of each Fourier harmonic of the gyroscope signal deviates from the true sinusoidal function, a quadrature-phase component appears, and the pi/2 rotation rates of harmonic components disagree. We evaluated the degree of scale factor degradation by defining the harmonic distortion ratio, which can be used as a measure for the reflectional quality of the gyroscopic optical system. The theory was verified by the response of an experimental gyroscope. The Fresnel reflection was eliminated by optical and electrical means, and the signal distortion of the experimental gyroscope was suppressed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号