首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   0篇
化学工业   3篇
能源动力   1篇
轻工业   2篇
一般工业技术   16篇
冶金工业   10篇
自动化技术   1篇
  2020年   1篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2010年   3篇
  2009年   1篇
  2008年   2篇
  2007年   4篇
  2004年   1篇
  2002年   1篇
  2001年   1篇
  1998年   1篇
  1997年   2篇
  1996年   4篇
  1993年   1篇
  1989年   1篇
  1987年   1篇
  1986年   2篇
  1985年   2篇
  1981年   1篇
  1966年   1篇
排序方式: 共有33条查询结果,搜索用时 15 毫秒
1.
2.
A high-accuracy cryogenic radiometer has been developed at the National Institute of Standards and Technology to serve as a primary standard for optical power measurements. This instrument is an electrical-substitution radiometer that can be operated at cryogenic temperatures to achieve a relative standard uncertainty of 0.021% at an optical power level of 0.8 mW. The construction and operation of the high-accuracy cryogenic radiometer and the uncertainties in optical power measurements are detailed.  相似文献   
3.
We briefly explain the fundamentals of detector nonlinearity applicable to both electrical and optical nonlinearity measurements. We specifically discuss the attenuation method for optical nonlinearity measurement that the NIST system is based upon, and we review the possible sources of nonlinearity inherent to thermal detectors used with high-power lasers. We also describe, in detail, the NIST nonlinearity measurement system, in which detector responsivity can be measured at wavelengths of 1.06 µm and 10.6 µm, over a power range from 1 W to 1000 W. We present the data processing method used and show measurement results depicting both positive and negative nonlinear behavior. The expanded uncertainty of a typical NIST high-power laser detector calibration including nonlinearity characterization is about 1.3 %.  相似文献   
4.
We report the results of a high-energy laser calorimeter comparison conducted by the National Institute of Standards and Technology (NIST), Boulder, Colorado and the U.S. Air Force Primary Standards laboratory (AFPSL), Heath, Ohio. A laser power meter, used as a transfer standard, was calibrated at each laboratory, sequentially, and the measurement results were compared. These measurements were performed at a nominal power of 800 W and a wavelength of 10.6 μm using CO2 lasers. Excellent measurement agreement (1.02 %) was demonstrated, which was well within each of the expanded uncertainties from the two laboratories involved in this comparison.  相似文献   
5.
We describe how the National Institute of Standards and Technology obtains a scale of absolute spectral response from 406 nm to 920 nm. This scale of absolute spectral response is based solely on detector measurements traceable to the NIST High Accuracy Cryogenic Radiometer (HACR). Silicon photodiode light-trapping detectors are used to transfer optical power measurements from the HACR to a monochromator-based facility where routine measurements are performed. The transfer also involves modeling the quantum efficiency (QE) of the silicon photodiode light-trapping detectors. We describe our planned quality system for these measurements that follows ANSI/NCSL Z540-1-1994. A summary of current NIST capabilities based on these measurements is also given.  相似文献   
6.
The National Institute of Standards and Technology (NIST) is establishing an infrared detector calibration facility to improve radiometric standards at infrared wavelengths. The absolute response of the cryogenic bolometer that serves as the transfer standard for this facility is being linked to the NIST high- accuracy cryogenic radiometer (HACR) at a few laser wavelengths. At the 10.6-microm CO(2) laser line, this link is being established through a pyroelectric detector that has been calibrated against the HACR. We describe the apparatus, methods, and uncertainties for the calibration of this pyroelectric detector.  相似文献   
7.
8.
We report results of the first bilateral laser power comparison for 248 nm KrF excimer lasers accomplished by the National Metrology Institutes of Germany (Physikalisch-Technische Bundesanstalt, PTB) and of the United States of America (National Institute of Standards and Technology, NIST). Laser transfer standards for average power were calibrated at both laboratories. The average powers were approximately 0.5 W, 1 W and 2 W. At 248 nm, the relative agreement was between 1×10−3 and 6×10−3, which is well within the expanded uncertainty of the bilateral degree of equivalence of approximately 2×10−2. Thus, this comparison confirms that the measurement procedures of both laboratories are consistent and the uncertainty budgets contain all significant contributions.  相似文献   
9.
The Système International des Unités (SI) base unit for photometry, the candela, has been realized by using absolute detectors rather than absolute sources. This change in method permits luminous intensity calibrations of standard lamps to be carried out with a relative expanded uncertainty (coverage factor k = 2, and thus a 2 standard deviation estimate) of 0.46 %, almost a factor-of-two improvement. A group of eight reference photometers has been constructed with silicon photodiodes, matched with filters to mimic the spectral luminous efficiency function for photopic vision. The wide dynamic range of the photometers aid in their calibration. The components of the photometers were carefully measured and selected to reduce the sources of error and to provide baseline data for aging studies. Periodic remeasurement of the photometers indicate that a yearly recalibration is required. The design, characterization, calibration, evaluation, and application of the photometers are discussed.  相似文献   
10.
We consider the inhomogeneous extensional response of a new constitutive model, the VCM model [Vasquez, et al., 2007. A network scission model for wormlike micellar solutions I: model formulation and homogeneous flow predictions. J. Non-Newt. Fluid Mech. 144, 122-139] that has been developed to describe concentrated solutions of wormlike micelles. The time dependent numerical analysis is carried out in a simplified slender filament formulation appropriate for transient elongational flows of complex fluids. The simulations show that, beyond a critical extension rate, elongating filaments of a micellar fluid described by the VCM model exhibit a dramatic and sudden rupture event as a result of the scission of the entangled wormlike chains. The computations capture many of the features of the high-speed rupture process observed experimentally [Bhardwaj, et al., 2007. Filament stretching and capillary breakup extensional rheometry measurements of viscoelastic wormlike micelle solutions. J. Rheol. 51, 693-719] in filament stretching experiments with wormlike micelle solutions. The highly localized rupture predicted by the VCM model and the corresponding evolution in the tensile force within the filament is contrasted with the familiar and more gradual necking responses predicted by the upper convected Maxwell and Giesekus models under equivalent kinematic boundary conditions.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号