全文获取类型
收费全文 | 90篇 |
免费 | 0篇 |
专业分类
电工技术 | 1篇 |
化学工业 | 34篇 |
机械仪表 | 1篇 |
建筑科学 | 5篇 |
能源动力 | 5篇 |
轻工业 | 2篇 |
无线电 | 7篇 |
一般工业技术 | 10篇 |
冶金工业 | 2篇 |
自动化技术 | 23篇 |
出版年
2023年 | 1篇 |
2021年 | 1篇 |
2020年 | 1篇 |
2018年 | 1篇 |
2017年 | 2篇 |
2016年 | 2篇 |
2015年 | 1篇 |
2014年 | 11篇 |
2013年 | 1篇 |
2012年 | 4篇 |
2011年 | 2篇 |
2010年 | 9篇 |
2009年 | 5篇 |
2008年 | 6篇 |
2007年 | 5篇 |
2006年 | 4篇 |
2005年 | 8篇 |
2004年 | 3篇 |
2003年 | 4篇 |
2002年 | 1篇 |
2001年 | 2篇 |
2000年 | 7篇 |
1998年 | 1篇 |
1997年 | 1篇 |
1996年 | 3篇 |
1994年 | 1篇 |
1993年 | 1篇 |
1992年 | 1篇 |
1989年 | 1篇 |
排序方式: 共有90条查询结果,搜索用时 0 毫秒
1.
Shrutee Lakshminarasimha Abhinav Maurya Govind Sharan Gupta Gadi Venkat Arun Chaitanya 《加拿大化工杂志》2023,101(2):883-895
The lateral flow of gas–powder through a packed bed in a cold model is studied to understand the flow and holdup behaviour of powder in the presence of a cavity, nozzle (tuyere) protrusion, and decreasing gas condition, a system used in the ironmaking blast furnace. Experiments conducted in the current study included a two-dimensional (2D) slot-type packed bed. A previously published mass balance and elutriation velocity concept formed the basis for accurately quantifying the static and dynamic powder holdups. Experiments conducted under different conditions such as powder size and flux, gas flow rate, and packed particle density and size resulted in quantifying the powder holdups. The pressure drop in both horizontal and vertical directions is studied in all two-phase flow experiments. The formation of the static holdup with time in the packed bed is studied. The reproducibility of the experiments was confirmed. The static holdup inside the packed bed at various locations along the vertical direction (i.e., height) is also quantified. The static holdup correlation developed based on experimental data resulted in a 95% confidence interval. Static powder holdup increases with a decrease in the superficial gas velocity, an increase in the size of the powder particle, and powder flux. Dynamic holdup also showed a similar trend. 相似文献
2.
The sweetpotato weevil, Cylas formicarius (Fabricius) (Coleoptera: Brentidae), is the most serious pest of sweetpotato around the world, damaging sweetpotatoes in the field and in storage, as well as being a quarantine pest. Because the larval period is spent within vines or tubers, and the adults are nocturnal, chemical control frequently is not effective. In addition, there are few natural enemies, and pheromone-based trapping does not appear to reduce the damage level. In the present study, we evaluated a number of parameters that affect pheromone-based trap catch, including trap design, trap size, trap color, and height at which the traps are placed. Pherocon unitraps caught higher numbers than ground, funnel water, or delta traps. Medium-sized traps (13?×?17.5 cm) were more effective than larger or smaller traps. In a color-choice test, C. formicarius preferred red over gray, brown, blue, white, yellow, black, or red traps; light red was more attractive than other shades of red. Maximum catches were obtained when the traps were set 50 cm above the crop canopy. Light-red unitraps with pheromone lures caught more adults than identical traps without lures, suggesting that C. formicarius is influenced by both visual and olfactory cues. Pheromone-baited light-red unitraps, 13?×?17.5 cm, installed 50 cm above the crop canopy, were the most effective at catching C. formicarius adults, and they appear to have the greatest potential for use in trap-and-kill strategies and eradication programs. 相似文献
3.
Mohamed B. Gadi 《Applied Energy》2000,65(1-4):355-366
This paper presents the results of simulating the ventilation and thermal performance of a new passive cooling and heating system. The new system was integrated into the roof of a typical contemporary North African house, which was modelled and mounted inside a wind tunnel, for natural ventilation simulation. Thermal performance of the new system was simulated using a new computer programme (BTS), developed by the author. Results are presented in terms of indoor temperature and CATD and HATD, which are newly introduced concepts in defining the building cooling and heating loads. 相似文献
4.
In this work, we consider the problem of solving , , where b
(k+1) = f(x
(k)). We show that when A is a full matrix and , where depends on the specific software and hardware setup, it is faster to solve for by explicitly evaluating the inverse matrix A
−1 rather than through the LU decomposition of A. We also show that the forward error is comparable in both methods, regardless of the condition number of A. 相似文献
5.
6.
This paper presents a mathematical model that was developed specifically to calculate the produced shaded and sunlit areas in a circular courtyard geometry. It examines the interaction taking place between the sun at any time throughout the year and a circular courtyard form with any dimensions and proportions in any place on the earth. This model was included in a new computer program, which allowed detailed investigation to be undertaken into the effect of circular courtyard proportions on the generated wall and floor exposed and shaded areas. The results showed that changing the form's proportions significantly influences the shading or exposure potential of the internal courtyard envelope. 相似文献
7.
Suresh K. Gadi Antonio Osorio-Cordero Rogelio Lozano-Leal Ruben A. Garrido 《Journal of Intelligent and Robotic Systems》2017,86(2):215-224
This paper presents a stability analysis of the interaction between a human and a linear moving Force Augmenting Device (FAD). The analysis employs a mathematical model of the human arm, the FAD and their interaction. As a depart from past works, this article presents a stability analysis considering time-delays in the human model. A key ingredient in the analysis is the use of the Rekasius substitution for replacing the time-delay terms. It is proved that the human machine interaction is stable when the human model has no delays. When delays are considered in the human model, the analysis provides an upper bound for the time-delays preserving a stable interaction. Numerical simulations allow to assess the human-FAD interaction. An experiment is performed with a laboratory prototype, where a human operator lifts a load. It is observed that the human machine interaction is stable and the human operator is able to move the load to a desired position by experiencing very little effort. 相似文献
8.
The practical difficulties encountered in analyzing the kinetics of new reactions are considered from the viewpoint of the capabilities of state-of-the-art high-throughput systems. There are three problems. The first problem is that of model selection, i.e., choosing the correct reaction rate law. The second problem is how to obtain good estimates of the reaction parameters using only a small number of samples once a kinetic model is selected. The third problem is how to perform both functions using just one small set of measurements. To solve the first problem, we present an optimal sampling protocol to choose the correct kinetic model for a given reaction, based on T-optimal design. This protocol is then tested for the case of second-order and pseudo-first-order reactions using both experiments and computer simulations. To solve the second problem, we derive the information function for second-order reactions and use this function to find the optimal sampling points for estimating the kinetic constants. The third problem is further complicated by the fact that the optimal measurement times for determining the correct kinetic model differ from those needed to obtain good estimates of the kinetic constants. To solve this problem, we propose a Pareto optimal approach that can be tuned to give the set of best possible solutions for the two criteria. One important advantage of this approach is that it enables the integration of a priori knowledge into the workflow. 相似文献
9.
The aim of this paper is to compare the implementation of computational fluid dynamics (CFD) and Network models for airflow rate estimation in buildings. The CFD software used is Fluent 5.5. Comparison between the predicted and simulated airflow rate is suggested as a validation method of the implemented CFD code, while the common practice is to compare CFD outputs to wind tunnel or full-scale measurements. This could be useful for studies that have no access to laboratory or full-scale testing facilities. Results obtained from testing a number of cases have been compared and analysed, considering normal and oblique wind directions. The comparison held between mathematical and CFD results generally showed a good agreement, which seems to justify the use of CFD code for predicting natural ventilation in buildings. 相似文献
10.