Catalysis Letters - We gave an effective protocol to support Ru NPs on amine-functionalized SBA-15 mesoporous silica to catalyze the CO2 hydrogenation reaction. The amine groups present in the... 相似文献
Surface integrity characterization of manufactured component is very important as it significantly affects the in-service performance of the component. Till now, surface integrity was evaluated using conventional measurement technique like microhardness tester, X-ray diffraction, optical microscopy and surface roughness tester. But, this technique being laboratory based cannot be used for in-service monitoring of the surface integrity. The present study focuses on the characterization of surface integrity upon electric discharge machined sample using non-destructive magnetic Barkhausen noise technique. Electric discharge machining was performed in die-sinking mode on die steel using copper–tungsten electrode (negative polarity). Experiment was performed by selecting different levels of peak current, gap voltage and pulse on time. Surface integrity characteristics like microhardness change, residual stress, microstructural alteration and surface roughness were analysed using microhardness tester, X-ray diffraction, optical microscopy and surface roughness tester, respectively, and were then correlated with magnetic parameter like root mean square value and peak value obtained from Barkhausen noise signal. The results show a good correlation between magnetic parameter (RMS and Peak value) of Barkhausen noise with the microhardness and surface roughness of the machined sample.
We investigate the challenges of building an end-to-end cloud pipeline for real-time intelligent visual inspection system for use in automotive manufacturing. Current methods of visual detection in automotive assembly are highly labor intensive, and thus prone to errors. An automated process is sought that can operate within the real-time constraints of the assembly line and can reduce errors. Components of the cloud pipeline include capture of a large set of high-definition images from a camera setup at the assembly location, transfer and storage of the images as needed, execution of object detection, and notification to a human operator when a fault is detected. The end-to-end execution must complete within a fixed time frame before the next car arrives in the assembly line. In this article, we report the design, development, and experimental evaluation of the tradeoffs of performance, accuracy, and scalability for a cloud system. 相似文献
The technology to produce compatibilized blends of liquid crystalline polymer and highly amorphous cyclic olefin copolymers through two novel approaches were studied. The first approach was to use silane-functionalized halloysite nanotube as nonspecific compatibilizer and the second method was reactive compatibilization. The study of blends and their resulting microstructure; their thermal, mechanical, and viscoelastic properties were investigated. The kinetic study of blends compatibilized through both routes was performed. 相似文献
Based on a high-performance liquid chromatographic pump, we have built a device that allows recirculation of DNA through a 63-microm orifice with ensuing fractionation to a minimum fragment size of approximately 300 base pairs. Residence time of the DNA fragments in the converging flow created by a sudden contraction was found to be sufficiently long to allow extension of the DNA molecules into a highly extended conformation and, hence, breakage to occur at midpoint. In most instances, 30 passages sufficed to obtain a narrow size distribution, with >90% of the fragments lying within a 2-fold size distribution. The shear rate required to achieve breakage was found to be inversely proportional to the 1.0 power of the molecular weight. Compared with a restriction digest, up to 40% of all fragments could be cloned directly, with only marginal improvements in cloning efficiency having been observed upon prior end repair with Klenow, T4 polymerase or T4 polynucleotide kinase. Sequencing revealed a fairly random distribution of the fragments. 相似文献
An automated gel electrophoresis apparatus, recently available commercially, allows one to follow the band during electrophoresis in real time, and lends itself therefore to an evaluation of bandwidth as a function of migration time (the dispersion coefficient), resolution and band shape. These determinations assume the constancy of band area with migration time and at various gel concentrations. The purpose of the present study was to verify these assumptions. Representative proteins and sodium dodecyl sulfate (SDS)-proteins, either natively fluorescent or fluorescein carboxylate labeled, were found to exhibit band areas which approach constancy as a function of migration time in both agarose and polyacrylamide gel electrophoresis, provided that (i) the protein concentration under the band was low enough to obviate self-quenching of fluorescence; (ii) the separation of the protein of interest from contaminants had progressed sufficiently during the time at which band areas were measured; (iii) the baseline under the peak was sufficiently well defined. However, band areas decrease with increasing gel concentration. Protein peaks exhibited leading and trailing tails. The ratio of the combined tail area to total area appeared to be near-constant at varying migration times. However, that ratio increases with increasing gel concentration. The tail area does not appear to be an artifact of fluorometric detection since it is reproduced upon fluorimetric analysis of the protein eluted from gel slices after electrophoresis. However, it may be due to photochemical destruction under the conditions of repetitive fluorometric peak detection. 相似文献