In p-GaN implanted with Mn (3×1016 cm−2 at 250 keV), the material after annealing shows ferromagnetic properties below 250 K. Cross-sectional transmission electron
microscopy (TEM) revealed the presence of platelet structures with hexagonal symmetry. These regions are most likely GaxMn1−xN, which produce the ferromagnetic contribution to the magnetization. In p-GaN implanted with Fe, the material after annealing
showed ferromagnetic properties at temperatures that were dependent on the Fe dose, but were below 200 K in all cases. In
these samples, TEM and diffraction analysis did not reveal any secondary phase formation. The results for the Fe implantation
are similar to those reported for Fe doping during epitaxial growth of GaN. 相似文献
Leukocyte depletion improves early postischemic ventricular performance in neonatal models of global myocardial ischemia. However, the rate of leukocyte reaccumulation after cardiopulmonary bypass and its subsequent impact on myocardial function is not known. This laboratory study examined the effect of leukocyte depletion on myocardial performance during the initial 6-hour period after bypass in an in situ, in vivo porcine model of neonatal cardiac surgery. Fifteen 3- to 5-day-old piglets (eight control and seven leukocyte depleted animals) were instrumented by placement of left ventricular short-axis sonomicrometry crystals and an intraventricular micromanometer catheter. Mechanical leukocyte depletion was achieved with Pall RC100 filters (Pall Biomedical, Inc., Fajardo, Puerto Rico) in the cardiopulmonary bypass circuit. Neonatal hearts were subjected to 90 minutes of hypothermic ischemia after a single dose of cold crystalloid cardioplegia. Two control animals died after the operation and were excluded from data analysis. Leukocyte filtration reduced the granulocyte count during initial myocardial reperfusion to 0.8% of control values. However, circulating granulocyte counts increased in leukocyte depleted animals throughout the postoperative period, reaching 68% of control values by 6 hours. Despite this rapid return of circulating granulocytes, animals subjected to leukocyte depletion had significantly better preservation of left ventricular performance (measured by preload recruitable stroke work, p < or = 0.02), left ventricular systolic function (measured by end-systolic pressure-volume relationship, p < or = 0.05), and ventricular compliance (p < or = 0.04) during the experiment. These changes in ventricular function were associated with a significant increase in left ventricular water content (p < or = 0.02) and tissue myeloperoxidase activity (p < or = 0.005) in control animals compared with leukocyte depleted animals. This study demonstrates that leukocyte depletion during initial reperfusion results in sustained improvement in postischemic left ventricular function despite the rapid return of granulocytes to the circulation. 相似文献
Based on a high-performance liquid chromatographic pump, we have built a device that allows recirculation of DNA through a 63-microm orifice with ensuing fractionation to a minimum fragment size of approximately 300 base pairs. Residence time of the DNA fragments in the converging flow created by a sudden contraction was found to be sufficiently long to allow extension of the DNA molecules into a highly extended conformation and, hence, breakage to occur at midpoint. In most instances, 30 passages sufficed to obtain a narrow size distribution, with >90% of the fragments lying within a 2-fold size distribution. The shear rate required to achieve breakage was found to be inversely proportional to the 1.0 power of the molecular weight. Compared with a restriction digest, up to 40% of all fragments could be cloned directly, with only marginal improvements in cloning efficiency having been observed upon prior end repair with Klenow, T4 polymerase or T4 polynucleotide kinase. Sequencing revealed a fairly random distribution of the fragments. 相似文献
An automated gel electrophoresis apparatus, recently available commercially, allows one to follow the band during electrophoresis in real time, and lends itself therefore to an evaluation of bandwidth as a function of migration time (the dispersion coefficient), resolution and band shape. These determinations assume the constancy of band area with migration time and at various gel concentrations. The purpose of the present study was to verify these assumptions. Representative proteins and sodium dodecyl sulfate (SDS)-proteins, either natively fluorescent or fluorescein carboxylate labeled, were found to exhibit band areas which approach constancy as a function of migration time in both agarose and polyacrylamide gel electrophoresis, provided that (i) the protein concentration under the band was low enough to obviate self-quenching of fluorescence; (ii) the separation of the protein of interest from contaminants had progressed sufficiently during the time at which band areas were measured; (iii) the baseline under the peak was sufficiently well defined. However, band areas decrease with increasing gel concentration. Protein peaks exhibited leading and trailing tails. The ratio of the combined tail area to total area appeared to be near-constant at varying migration times. However, that ratio increases with increasing gel concentration. The tail area does not appear to be an artifact of fluorometric detection since it is reproduced upon fluorimetric analysis of the protein eluted from gel slices after electrophoresis. However, it may be due to photochemical destruction under the conditions of repetitive fluorometric peak detection. 相似文献
On the basis of observations that endemic fluorosis occurs more often in malnourished populations, a series of studies tested the hypothesis that deficient dietary intake of calcium, protein or energy affects fluoride metabolism so that the margin of safe fluoride exposure may be reduced. The objective of the investigation was to determine whether changes in fluoride metabolism in nutritionally deficient rats resulted in manifestation of any extraskeletal toxic fluoride effects not observed in healthy animals. This investigation included two studies, one that monitored the effect of calcium deficiency on the effects of chronic fluoride exposure, and a second study that observed fluoride effects in rats that were deficient either in protein or in energy and total nutrient intake. Control and experimental rats received drinking water containing 0, 0.26 (5), 0.79 (15) or 2.63 (50) mmol fluoride/L (mg/L) for 16 or 48 wk. Control rats were fed optimal diets and experimental rats were fed diets deficient in calcium (Study 1) or protein (Study 2). An additional group of experimental rats (Study 2) was provided with a restricted amount of diet; thus these rats were deficient in energy and total nutrient intake. The intake, excretion and retention of fluoride were monitored; after the rats were killed, tissue fluoride levels and biochemical markers of tissue function were analyzed. Bone marrow cells were harvested from some of the rats, after 48 wk of treatment, for determining the frequency of sister chromatid exchange, a marker of genetic damage. Although there were significant differences among fluoride treatment groups in fluoride excretion and retention that resulted in significantly greater fluoride levels in tissues of the experimental rats, we were unable to detect any harmful, extraskeletal biochemical, physiologic or genetic effects of fluoride in the nutritionally deficient rats. 相似文献
A CEC-funded project has been performed to tackle the problem of producing an advanced Life Monitoring System (LMS) which would calculate the creep and fatigue damage experienced by high temperature pipework components. Four areas were identified where existing Life Monitoring System technology could be improved:
1. 1. the inclusion of creep relaxation
2. 2. the inclusion of external loads on components
3. 3. a more accurate method of calculating thermal stresses due to temperature transients
4. 4. the inclusion of high cycle fatigue terms.
The creep relaxation problem was solved using stress reduction factors in an analytical in-elastic stress calculation. The stress reduction factors were produced for a number of common geometries and materials by means of non-linear finite element analysis. External loads were catered for by producing influence coefficients from in-elastic analysis of the particular piping system and using them to calculate bending moments at critical positions on the pipework from load and displacement measurements made at the convenient points at the pipework. The thermal stress problem was solved by producing a completely new solution based on Green's Function and Fast Fourier transforms. This allowed the thermal stress in a complex component to be calculated from simple non-intrusive thermocouple measurements made on the outside of the component. The high-cycle fatigue problem was dealt with precalculating the fatigue damage associated with standard transients and adding this damage to cumulative total when a transient occurred.
The site testing provided good practical experience and showed up problems which would not otherwise have been detected. 相似文献