首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   42篇
  免费   0篇
化学工业   6篇
金属工艺   3篇
建筑科学   1篇
矿业工程   3篇
轻工业   2篇
无线电   2篇
一般工业技术   9篇
冶金工业   14篇
自动化技术   2篇
  2020年   1篇
  2018年   2篇
  2016年   1篇
  2015年   1篇
  2014年   2篇
  2013年   4篇
  2010年   2篇
  2009年   2篇
  2008年   2篇
  2007年   1篇
  2006年   1篇
  2005年   1篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
  2001年   1篇
  1999年   1篇
  1997年   4篇
  1995年   2篇
  1992年   1篇
  1991年   4篇
  1990年   1篇
  1984年   2篇
  1966年   1篇
  1947年   1篇
  1941年   1篇
排序方式: 共有42条查询结果,搜索用时 31 毫秒
1.
Interactions in aqueous solution between pilocarpine hydrochloride (P-HCl), a rather hydrophilic drug with good water solubility, and various cyclodextrins (CDs) were described recently. To assess the influence of CDs on the diffusion behavior of pilocarpine, in vitro studies were performed using porcine or bovine corneas as diffusion barriers. The affinity of P-HCl for porcine cornea in the presence of alpha-cyclodextrin (alpha-CD) and (hydroxyethyl)-beta-cyclodextrin (HE-beta-CD) was determined by drug uptake experiments. Additionally, in vitro permeation experiments through bovine corneas were conducted with a modified diffusion device optimized for corneal perfusion studies. The results obtained from the corneal uptake studies indicate that the addition of alpha-CD led to increased tissue drug levels. The increase in permeability of pilocarpine in the presence of alpha-CD was approximately 10-fold (log Papp = -4.87 +/- 0.03) in comparison with plain P-HCl solution (log Papp = -5.89 +/- 0.06). Permeation studies with corneas pretreated with alpha-CD solution revealed enhanced corneal permeability of pilocarpine due to alpha-CD induced membrane effects. The hydroxyalkylated beta-CD derivatives HE-beta-CD (log Papp = -6.27 +/- 0.09) and (hydroxypropyl)-beta-cyclodextrin (HP-beta-CD; log Papp = -6.40 +/- 0.03), however, seemed to cause slightly decreased permeation rates, supporting the concept of an interaction between pilocarpine and the hydroxyalkylated-beta-CD derivatives. Considering physiological compatibility, the addition of CDs seems to be an effective tool to modify and optimize the ocular availability of pilocarpine.  相似文献   
2.
The aim of the present study was to investigate the effect of a 10 Hz alternating current (10 Hz 1 V cm−1) and a 50 Hz alternating current (50 Hz 1 V cm−1) on the lettuce plant (Lactuca sativa) growing in a hydroponic (soil-free) culture. Thirty lettuce plants were pre-germinated, and then 15 of them were treated with cadmium solution (CdCl2) of 5 mg/L in concentration. Ten plants (five plants with Cd and five plants without Cd) were subjected to a 10 Hz alternating current (AC) electrical field; 10 plants were subjected to a 50 Hz AC field. The rest of the plants were used as a control. The lettuce plants were harvested after a growth of 60 days. The chlorophyll content, biomass and metal content of the lettuce plants were determined. The biomass of the plants growing in non-contaminated medium was 28 and 106% higher under the 10 and the 50 Hz AC fields respectively compared to the control. Although the plant biomass was reduced by the presence of Cd in the growth medium, the biomass of the plants growing in Cd contaminated medium was 40 and 63% higher respectively for 10 and 50 Hz AC field compared to the plant growing in Cd contaminated medium without electrical treatment. Increased uptake of Cd in the plant shoot was found with the 50 Hz AC field. Significant accumulation and uptake of Cu in plant roots and shoots was found under both electrical treatments.  相似文献   
3.
4.

A fluidized bed aerosol generator has been designed and built for the purpose of generating a constant output of dry, submicrometer particles with a large number density. The output of the fluidized bed for generating aerosol particles from dry soot powder has been characterized using a differential mobility analyzer and a condensation particle counter. The particle size distribution is bimodal, with a mode in the submicrometer diameter size range and a mode in the supermicrometer diameter size range. The larger diameter mode is fully separated from the smaller mode and can thus be easily removed from the aerosol flow using impaction techniques. The distribution in the submicrometer size range is nearly log-normal, with a count median diameter falling between 0.1 and 0.3 micrometers. A number density of greater than 105 particles cm-3 of soot particles in the submicrometer range can be produced, constant to within 25% (1 standard deviation) over a 4 h time period. The number density of particles produced in the submicrometer range was found to vary with the ratio of soot to bronze beads in the bed mixture, whether or not a feed system was used, and nitrogen flow rate through the fluidized bed and feed system.  相似文献   
5.
The present studies focus on strategies for detecting back irrelevant responding (BIR) on the Personality Assessment Inventory (PAI; L. C. Morey, 1991). Moderate BIR levels can greatly affect the clinical scales of the PAI. Further, the PAI's Inconsistency and Infrequency validity scales are less than optimal for detecting BIR. L. C. Morey and C. J. Hopwood (2004) developed an alternative strategy for detecting BIR that involves comparison of 2 scales from the PAI short-form with the same 2 scales from the PAI full-instrument. The present study examines how different BIR levels affect the clinical, treatment, and interpersonal scales of the PAI in 2 psychiatric inpatient samples. The effectiveness of various strategies for detecting BIR in an inpatient setting is also discussed. Consistent with previous research, moderate rates of BIR impacted several PAI scales in a meaningful way. The Inconsistency and Infrequency validity scales of the PAI were relatively ineffective for detecting low-to-moderate BIR levels. Conversely, the short-form full-instrument comparison strategy was much more sensitive to BIR. Finally, a new BIR detection indicator is presented that improves sensitivity rates for detecting all BIR levels in an acute setting. The implications of these results for detecting BIR in inpatient settings are discussed. (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   
6.
In recent years, several incidents of cracking and failures have been observed in Stellite (Stellite is a registered trademark of the Deloro-Stellite Corporation) hardfacing used in valves of modern high temperature combined cycle gas fired power plants. These hardfacing layers are applied as an overlay onto a steel substrate, such as CrMo steel (i.e. Grade 22, WC9) or creep strength enhanced ferritic steel (i.e. Grade 91, C12A). Cracking has been observed in valve components at the Stellite/steel interface and in the weld dilution zone formed between the steel and clad. Ultimately, disbonding or delamination of the weld hardfacing from the valve body occurs and has resulted in collateral damage to components in the plant (such as to the turbine) or valve failure. In this study, the microstructure formed near the Stellite/steel interface is investigated. Based on thermodynamic modelling, microstructure formed at these regions is hypothesised and a simple methodology is proposed to predict the occurrence of these failures.  相似文献   
7.
8.
Creep strength enhanced ferritic steels contain 9 to 12% Cr and were developed to exhibit excellent high temperature properties. These should be achieved when the microstructure exhibits a tempered martensitic matrix containing a substructure with a high dislocation density and a uniform dispersion of fine, second phase precipitates. It is interesting to note that when properly processed the typical alloy compositions for these steels provide reasonable strength but can exhibit brittle creep behaviour. The levels of ductility required in engineering applications necessitate proper control of composition (including trace elements), steel making and processing and all heat treatments. The properties needed for modern design methods can only be obtained using validated procedures for both uniaxial and multiaxial testing and documentation to establish the mechanisms controlling deformation and fracture for relevant stress states.  相似文献   
9.
Creep strength-enhanced ferritic steels, such as Grade 91, are the preferred material for much of the high-energy boiler tubing and piping components used in modern power generating plants. Weld repair techniques that achieve the necessary performance without the need for high-temperature post weld heat treatment (PWHT) offer particular benefits for Grade 91 steel. These benefits arise since there are many examples of poor heat treatment control which have resulted in component microstructures with below the minimum properties expected by design codes. Furthermore, even a controlled PWHT at temperatures at around 760 °C will further temper the base material. This is significant because excessive base metal tempering is one suggested criterion requiring component replacement. Successful demonstration of controlled welding techniques linked to minimal or no PWHT would alleviate these problems. This article presents results from a major project which is aimed at considering options for designing a ‘well-engineered’ repair. In this project, the creep performance of candidate repair methods was evaluated using large, feature test-type specimens containing the entire weldment including both fusion lines and heat-affected zones. The results show that the cross-weld life in Grade 91 steels does not appear to be a function of whether or not the welding procedures include PWHT. The results offer the potential to qualify ‘cold’ weld repairs in these steels.  相似文献   
10.
Surface-welds of Hastelloy C4 and some mixed welds of Inconel 600 and Hastelloy C4 were prepared by the plasma-hot-wire-surface-welding method. Intercrystalline corrosion tests were performed in a diluted Streicher-solution. On-line recording of the corrosion potential uses the stability of the redox-pair, Fe(III)/Fe(II) (called the chemical potentiostat). Microscopic observations of specimens after corrosion accompanied the potential recording and gave valuable information about the morphology changes that occur due to intercrystalline corrosion. Potential measurements in a 1/3-diluted Streicher-Test solution showed that 2-layer surface-welds of Hastelloy C4, prepared by the hot-wire-surface-welding method with arc-deflection, were the most resistant to intercrystalline corrosion. A mixed 2-layer surface-weld of Inconel 600 inner-layer and Hastelloy C4 outer-layer was not effective due to the heterogeneous interface formed between both layers.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏